F-22
General-purpose Limit Switch
D4A-
@N
Head and Lever Positions
The operating head can be positioned and locked in any of four 90
°
positions and a lever can lock in any position through 360
°
around the shaft of
the Limit Switch. Furthermore, the lever can be reversed and attached to the shaft (refer to the figures below on the right hand side). Therefore the
roller is compatible with a wide movement range of a dog. A Fork Lever Lock can be used with maintained models (D4A-0005N) only.
Lighting Mode Selection of Indicators
The lighting mode of the operation indicator can be changed easily between two modes: lighting when the Switch is operating and lighting when
the Switch is not operating.
Loosen the screw
to adjust the
length of the rod.
Loosen the bolt to
adjust the length
of the lever.
Adjustable
between 33
and 91 mm
D4A-E00
D4A-E10
D4A-E20
D4A-E30
Four, M4 x 12
Remove the head from the Switch by
loosening the screws (the screws can be
loosened but not removed from the
head).
The operating head can be
positioned and locked in
any of four 90
°
positions.
The lever can lock in any position through 360
°
around
the shaft. The lever can be reversed and attached to the
shaft, in which case the switching operation should com-
plete in a range of 0
°
to 180
°
.
By loosening the Allen-head bolt on an adjustable roller lever
or rod lever, the length of the lever can be adjusted.
D4A-C00
D4A-D00
180
°
operating
position
360
°
operating
position
There are four kinds of fork lever locks. The position of each
roller is different. It is possible to use D4A-E00 through
D4A-E30 levers instead, if they are reversed before attaching.
They can be used with D4A-
@@
05N models only.
4
3
1
2
4
3
1
2
Load
NO
NC
NO
NC
Power supply
Load
Power supply
Lights When Not Operating
Lights When Operating
Lamp
unit
Lamp
unit
Built-in
switch
Note: 1.
The lamp is lit when the actuator is at the free position.
The lamp will be off when the contacts of the Limit
Switch have been actuated and snapped to each other
at the operating position.
2.
The lamp is lit when the contacts have been released
and snapped only from the operating position.
Built-in
switch
(See note 1.)