Small Sealed Switch
D4E-
@
N
F-33
Lim
it
Switch
es
Specifications
■
Approved Standards
■
Approved Standard Ratings
UL, CSA
A300
TÜV (EN60947-5-1)
Note: 1.
@
: Actuator variation of item II
2.
AC-14 0.5 A/125 VAC means as follows:
Applicable category: AC-14
Rated operating current (I
e
): 0.5 A
Rated operating voltage (U
e
): 125 VAC
Agency
Standard
File No.
UL
UL508
E76675
CSA
CSA C22.2 No. 14
LR45746
TÜV Rheinland
EN60947-5-1
R9551015
Voltage
Carry current
Current
Volt-amperes
Make
Break
Make
Break
120 V
10 A
60 A
6 A
7,200 VA
720 VA
240 V
30 A
3 A
Model
Applicable category and ratings
Thermal
current (I
the
)
Indicator
I
II
III
IV
1
@
00
AC-14 0.5 A/125 VAC
5 A
---
1
@
10
DC-12 0.5 A/30 VDC
5 A
---
1
@
20, 21, 22
AC-15 2A/250 VAC
DC-12 2A/48 VDC
5 A
---
1
@
23, 24
L
AC-15 2A/250 VAC
5 A
Neon lamp
1
@
23, 24
L1
DC-12 2A/12 VDC
5 A
LED
1
@
23, 24
L2
DC-12 2A/24 VDC
5 A
LED
1
@
23, 24
L3
DC-12 2A/48 VDC
5 A
LED
2
@
00
AC-14 0.1A/125 VAC
0.5 A
---
2
@
10
DC-12 0.1A/30 VDC
0.5 A
---
2
@
20, 21, 22
AC-14 0.1A/125 VAC
DC-12 0.1A/48 VDC
0.5 A
---
2
@
23, 24
L
AC-14 0.1A/125 VAC
0.5 A
Neon lamp
2
@
23, 24
L1
DC-12 0.1A/12 VDC
0.5 A
LED
2
@
23, 24
L2
DC-12 0.1A/24 VDC
0.5 A
LED
2
@
23, 24
L3
DC-12 0.1A/48 VDC
0.5 A
LED
I II III IV
D4E-
1 G 23 L N