F-34
Small Sealed Switch
D4E-
@
N
■
Ratings
Note: 1.
The above current ratings are for a standard current and the values in parentheses are for models with a connector.
2.
Inductive loads have a power factor of 0.4 min. (AC) and a time constant of 7 ms max. (DC).
3.
Lamp load has an inrush current of 10 times the steady-state current.
4.
Motor load has an inrush current of 6 times the steady-state current.
■
Characteristics
Note: 1.
The above values are initial values.
2.
The above ratings may vary depending on the model. Contact your OMRON representative for further details.
3.
Durability values are calculated at an operating temperature of 5
°
C to 35
°
C, and an operating humidity of 40% to 70%. Contact your
OMRON sales representative for more detailed information on other operating environments.
Rated voltage
General-purpose
Micro load
Non-inductive load
Inductive load
Non-inductive load
Resistive load
Lamp load
Inductive load
Motor load
Resistive load
NC
NO
NC
NO
NC
NO
NC
NO
NC
NO
125 VAC
5 (1) A
1.5 (1) A
3 (1) A
2 (1) A
1 (1) A
0.1 A
250 VAC
5 (1) A
1.5 (1) A
3 (1) A
1 A
0.5 A
---
8 VDC
5 (1) A
---
1.5 (1) A
---
0.1 A
14 VDC
5 (1) A
---
1.5 (1) A
---
0.1 A
30 VDC
5 (1) A
---
1.5 (1) A
---
0.1 A
125 VDC
0.5 A
---
0.05 A
---
---
250 VDC
0.25 A
---
0.03 A
---
---
Inrush current
NC
10 A max.
NO
10 A max.
Degree of protection
IP67
Durability (see note 3)
Mechanical: 10,000,000 operations min.
Electrical:
500,000 operations min. (5 A at 250 VAC, resistive load)
5,000,000 operations min. (10 mA at 24 VDC, resistive load)
Operating speed
0.1 mm to 0.5 m/sec
Operating frequency
Mechanical: 120 operations/min
Electrical:
30 operations/min
Rated frequency
50/60 Hz
Insulation resistance
100 M
Ω
min. (at 500 VDC)
Contact resistance
15 m
Ω
max. (initial value)
Dielectric strength
1,000 VAC, 50/60 Hz for 1 min between terminals of same polarity
1,500 VAC, 50/60 Hz for 1 min/Uimp at 2.5 kV (EN60947-5-1) between current-carrying metal parts
and ground, and between each terminal and non-current-carrying metal part
Rated insulation voltage (Ui)
250 VAC
Switching overvoltage
1,000 VAC max. (EN60947-5-1)
Pollution degree
(operating environment)
3 (EN60947-5-1)
Short-circuit protective device (SCPD)
10 A fuse (type gG or gI, IEC269 approved)
Conditional short-circuit current
100 A (EN60947-5-1)
Conventional enclosed thermal current
(I
the
)
5 A (EN60947-5-1)
Protection against electric shock
Class II (grounding not required with double insulation)
Vibration resistance
Malfunction: 10 to 55 Hz, 1.5-mm double amplitude
Shock resistance
Destruction: 1,000 m/s
2
min.
Malfunction: 300 m/s
2
min.
Ambient temperature
Operating: –10
°
C to 80
°
C (with no icing)
Ambient humidity
Operating: 95% max.
Weight
Approx. 86 g (in case of roller plunger)