vii
・
Do not let the product drop or subject it to a shock. Stop using the product if it has been applied with a
strong impact.
・
Don't connect a power supply to RS-485 communications line. There is fear of product damage.
・
Fix with only the conduit part when mounting pipe, or the product might damage.
<D6FZ-FGS1000>
・
Do not ground Brown colored wire (DC24V). As the enclosure is connected to
0V inside circuit, it is
short-circuited with your device FG.
・
Be sure to ground Blue colored wire + shield (0V) of single-end wire cable (D6FZ-JD
A).
<
D6FZ-FGT
>
・
Don't touch the current plate in the flow channel, or fingers might be injured.
・
Connect blue colored wire (0V) with the shield line of a single-end line cable (model D6FZ-JD
A, sold
separately). The shield line and the blue colored wire (0V) is connected inside form D6 FZ-JD
A.