background image

D6FZ

4

You can collect onsite data at an Air Flow Station data and use the Multi Data Viewer Light software to analyze 

the data in your office to identify other locations for improvement on the production site. 

O n   t h e  

P r o d u c t i o n  

S i t e :

Data monitoring and

storing by Air Flow

Station

Multi Data Viewer Light

Display period is easy to change.

Check boxes allow you to display only the required data.

Total flow rate (bar graph)

Pressure (dotted line graph)

This software displays data for specific time periods, such as by the minute, 

hour, or d ay. The tot al flow rate is dis played as a bar graph and the 

momentary flow rate and pressure are displayed with dotted lines, so you can 

see the overall situation at a glance.

Free

The PC Software

Download the PC Software Station Utility from the following OMRON website (http://www.fa.omron.co.jp/station-u-e).

Start data logging with a single 

press of a button.

Save the data to 
an SD memory card.

The Air Flow Station enables 
easy data logging.

The PC Software Easily Analyzes Logged Data

Yo u   c a n   u s e   c o m p a r a t i v e   d i s p l a y s   w i t h  
previously logged data. 
For example, side-by-side comparison of flow 
rates by the day for different months is possible.

e, 

e

In the Office:

Data storing and 

analyzing 

on a computer

By stopping the supply of compressed air with a solenoid valve when there 
is no workpiece, compressed air usage is reduced.  At the same time, the 
Flow Sensor monitors the quantity of supplied compressed air to ensure 
that it is within the specified range. Therefore, the Sensor helps maintain 
and improve quality.

By giving priority to the monitoring of molding machines and 
other machines that use large quantities of compressed air, 
energy is efficiently saved.

Set the leak threshold value to identify when 
repairs for leaks are required.

Monitor consumption and pressure fluctuations for each 
production line to identify bottleneck lines or machines to 
implement onsite improvements and save energy.

During operation

ON

OFF

When operation is stopped

Upper limit

Lower limit

leak

Leak output

During operation

When the leak increases

ON

OFF

When operation is stopped

Upper limit

Lower limit

leak

Leak output

You can save energy in a variety of applications.

Stop Ionizer Idling 

D6FZ-FGT

Flow Management for
Molding Machines

D6FZ-FGT

D6FZ-FGS

Leakage Management 
for Machines

D6FZ-FGT

D6FZ-FGS

Flow and Pressure 
Management for Production Lines

D6FZ-FGS

Summary of Contents for D6FZ Series

Page 1: ...s Features For the most recent information on models that have been certified for safety standards refer to your OMRON website Consequently Identify the waste that had previously been invisible to red...

Page 2: ...e and Temperature The Sensor provides multiple sensing functions You can identify compressed air conditions with just one Sensor Multi sensing Mountable to Curved Pipes or Couplers The built in silenc...

Page 3: ...n the flow rates Display Reversal You can reverse the display direction to match the installation direction Always use one of the specified installation directions 500L type Pipe size 15A Rc1 2 200L t...

Page 4: ...example side by side comparison of flow rates by the day for different months is possible e e n In the Office Data storing and analyzing on a computer By stopping the supply of compressed air with a s...

Page 5: ...ion T branch Connector Cable with Connector on One End 3 m D6FZ FGS1000 S Appearance Product name Model T branch Connector D6FZ FC02 D6FZ FGT Air Flow Sensor only Mounting Bracket Mounting Bracket 1 P...

Page 6: ...Pressure loss 2 kPa max 4 kPa max Power supply voltage 12 to 24 VDC 10 ripple p p 10 max Current consumption 120 mA max Functions Momentary flow total flow display reversal zero point adjustment peak...

Page 7: ...ections up down left right forward backward Pressure loss Direct piping 10 kPa max 0 5 MPa at maximum flow Using Coupler TL model from Nagahori Industry Co Ltd 10 kPa max 0 5 MPa at maximum flow Power...

Page 8: ...ry information indicators Recording interval 1 s 2 s 5 s 10 s 20 s 30 s or 1 min Displayed data Momentary flow rate total flow rate pressure temperature and billing amount CO2 conversion Recorded data...

Page 9: ...B B B B B B B Terminal block RS 485 RS 485 PLC 24 V power supply RS 485 Connections to Air Flow Station RS 485 Connections to PLC Refer to the user s manuals for the Wireless Unit and Air Flow Sensor...

Page 10: ...ic pressure 0 5MPa 0 75MPa 0 1 2 0 500 100 200 300 400 Pressure loss kPa Flow rate L min std atmospheric pressure 0 5MPa 0 75MPa 0 2 4 1 3 Temperature C Pressure MPa Minimum flow rate L min std Maximu...

Page 11: ...of straight pipe with the same opening diameter just before and after the Sensor Refer to Flow rate accuracy characteristics for a length of straight pipe on page 10 for the required straight pipe len...

Page 12: ...mm 15 47 15 Four 3 2 dia 0 1 holes 16 0 1 49 5 0 1 D6FZ FGT200 Mounting Hole Dimensions 63 7 30 33 7 77 12 65 70 60 89 65 Rc1 2 Effective depth 10 mm 49 5 0 1 16 0 1 7 Four M3 Effective depth 5 mm 30...

Page 13: ...7 10 12 4 5 dia through hole 8 dia countersinking depth 2 M12 plug CN0 CN1 CN2 14 9 dia 18 14 9 dia 14 9 dia 4 5 d i a t h r o u g h h o l e 8 d ia C o u n te rs u n k h o le d e p th 2 Back 56 M12 so...

Page 14: ...her in no event shall liability of Omron Companies exceed the individual price of the Product on which liability is asserted Suitability of Use Omron Companies shall not be responsible for conformity...

Reviews: