11
Preparation for Operation
Section 1-8
LED Indicators
The following table explains the operation of the LED indicators.
Board ID
When two or more DeviceNet PCI Boards are installed in a computer, the
computer uses the board ID settings to distinguish the Boards from each
other. Specify the board ID in API functions to identify the desired board.
Set the board ID in decimal as shown in the following diagram. The allowed
setting range is 0 to 7. (The factory setting is 0.)
Up to 3 DeviceNet PCI Boards can be installed in one computer.
Note
Any board ID from 0 to 7 can be set, as long as the ID is not set on another
DeviceNet PCI Board in the computer. (It is physically possible to set board
IDs 8 and 9, but the Board cannot be used properly with these settings.)
1-8
Preparation for Operation
Hardware Settings
If more than one DeviceNet PCI Board is being installed in one computer, set
the board IDs on the Boards’ rotary switches so that the different Boards can
be distinguished from one another. Refer to
2-2 Installing the Board in the
for details.
Always set the rotary switches before turning ON the computer.
Installation on Computer
Install the Board in the computer. Refer to
2-2 Installing the Board in the Com-
for details.
Software Installation
Install the DeviceNet PCI Board driver and software required to use the Board
from the computer. Refer to
and
for details.
Writing the Program
Write the programs (user applications) that make software settings and con-
trol the Board. Refer to
through
for details.
Reference Information
for information on communications cable
connections.
Refer to the
DeviceNet Operation Manual (W267)
for information on wiring
DeviceNet networks.
Refer to the
DeviceNet Slave Operation Manuals
(W404 and W347) and the
DeviceNet MULTIPLE I/O TERMINAL Operation Manual
(W348) for informa-
tion on Slaves.
Indicator status
Meaning
MS
NS
OFF
OFF
Boot program initialization is in progress.
Flashing green
OFF
Scanner firmware initialization is in progress.
Lit green
OFF
Waiting for online request.
Lit green
Flashing green
A connection was established and I/O communi-
cations are in progress.
Waiting for a connection from the Master.
Lit green
Lit green
I/O communications or message communications
are in progress.
Summary of Contents for DeviceNet 3G8F7-DRM21-E
Page 1: ...OPERATION MANUAL Cat No W381 E1 02 3G8F7 DRM21 E DeviceNet PCI Board ...
Page 2: ...3G8F7 DRM21 E DeviceNet PCI Board Operation Manual Revised July 2005 ...
Page 3: ...iv ...
Page 5: ...vi ...
Page 29: ...12 Preparation for Operation Section 1 8 ...
Page 67: ...50 PC Watchdog Timer Management Function Section 3 11 ...
Page 115: ...98 Maintenance API Functions Section 4 7 ...
Page 131: ...114 Remote I O Communications Characteristics Section 6 1 ...
Page 145: ...Index 128 ...
Page 147: ...130 Revision History ...