14
Installation Procedure
Section 2-1
2-1
Installation Procedure
There procedure for installing the DeviceNet PCI Board and its software is
outlined below.
Note
For Windows 2000 or XP, you must log in with administrator rights to install the
driver and Scanner SDK Software.
2-2
Installing the Board in the Computer
This section explains how to make the required settings on the DeviceNet PCI
Board and install the Board in the computer.
Preparation for
Installation
The DeviceNet PCI Board is plug-and-play compatible with MicroSoft Win-
dows. Check the following points before installing the Board.
Note
Use the following procedure to identify which IRQ numbers are being used by
the ISA bus.
1,2,3...
1.
Start the computer without the DeviceNet PCI Board installed.
2.
Start the Device Manager (
Control Panel/System/Device Manager
).
3.
Open the properties of the relevant devices and check their IRQ (Interrupt
Request) settings in the Resources tab.
Installing the Board in the Computer
Set the board ID (rotary switch) and install
the Board in the computer.
Installing the Driver
Install the DeviceNet PCI Board driver.
Installing the Scanner SDK Software
Install the provided Scanner SDK
software.
Windows NT 4.0
Windows 95, 98, Me, 2000, XP
Check point
Description
Available PCI slot
Make sure that the computer has an available PCI slot.
IRQ conflict
The DeviceNet PCI Board uses an IRQ.
IRQ settings are allocated automatically to the PCI bus, but
not to the ISA bus. In computers with ISA slots, the computer
may not boot completely if there is an IRQ conflict with the ISA
bus. In this case, make one of the following changes in the
BIOS settings:
• Enter the BIOS setup and specify a non plug-and-play (PnP)
operating system.
• Enter the BIOS setup and reserve the IRQ numbers (disable
automatic allocation of these IRQ numbers) that are used by
the ISA bus so that these IRQ numbers will not be allocated
automatically to the PCI bus.
Refer to the computer’s User’s Guide for details on entering
the BIOS setup and changing the settings. (See note below
for details on identifying IRQ numbers.)
Summary of Contents for DeviceNet 3G8F7-DRM21-E
Page 1: ...OPERATION MANUAL Cat No W381 E1 02 3G8F7 DRM21 E DeviceNet PCI Board ...
Page 2: ...3G8F7 DRM21 E DeviceNet PCI Board Operation Manual Revised July 2005 ...
Page 3: ...iv ...
Page 5: ...vi ...
Page 29: ...12 Preparation for Operation Section 1 8 ...
Page 67: ...50 PC Watchdog Timer Management Function Section 3 11 ...
Page 115: ...98 Maintenance API Functions Section 4 7 ...
Page 131: ...114 Remote I O Communications Characteristics Section 6 1 ...
Page 145: ...Index 128 ...
Page 147: ...130 Revision History ...