1.Before using the unit

Electrode Cord Plug

Attach the red or the
white plug to each Pad.

Tab of the Pad

Hold the Tab to peel
off the Pad.

Point & Wide Mode

Point

The unit treats the red and the
white sides alternately.

Wide

The unit treats both the red

and white sides simulta-
neously.

* Select either the Wide or the Point Button.

Balance Adjustment (Switching between red and 
white buttons)

R-button

The unit emphasizes therapy

on the red side.

W-button

The unit emphasizes therapy

on the white side.

Selecting 

Selecting 

Selecting None of Them

When  

is 

selected

Emphasis on intensity is 

placed upon the red side 

while treating both sides 

alternately.

Emphasis on intensity is 

placed upon the white side 

while treating both sides 

alternately.

Treats both red and white

 

sides with the same

 

intensity 

alternately.

When  

is 

selected

Emphasis on intensity is 

placed upon the red side 

while treating both sides 

simultaneously.

Emphasis on intensity is 

placed upon the white side 

while treating both sides 

simultaneously.

Treats both red and white

 

sides with the same

 

intensity 

simultaneously.

HV-F127 manual.book  Page 7  Monday, June 14, 2010  12:07 PM

Summary of Contents for E2 ELITE

Page 1: ...e d emploi Gebrauchsanweisung Manuale di istruzioni Manual de instrucciones Gebruiksaanwijzing P M SPECIAL MODE S 1 2 3 4 5 6 7 8 9 ELECTRONIC NERVE STIMULATOR EN FR DE IT ES NL IM HV F127 E 04 06 201...

Page 2: ...nic Nerve Stimulator 4 1 3 Features of the product 4 1 4 Intended use 4 1 5 Package contents 5 1 6 Information on high low frequency therapy 5 1 7 Names and functions of the parts 6 2 How to use the d...

Page 3: ...damage to the STIMULATOR Operation in close proximity e g 1 m to a shortwave or microwave therapy EQUIPMENT may produce instability in the STIMULATOR output Do not use this unit for purposes other tha...

Page 4: ...as endorphins are triggered Furthermore the blood flow through the treated body zones is improved 1 3 Features of the product 9 Automatic Programmes The device allows you to select your favourite sti...

Page 5: ...es is pumped out With repeated actions the blood flows smoother and the blood circulation is improved Shutting out pain signal When low frequency current flows to the region experiencing pain it acts...

Page 6: ...1200 Hz which helps to relieve acute pain promptly Region Button The unit treats the selected region with the effec tive programme Massage Button Select your favourite massage method according to you...

Page 7: ...izes therapy on the white side Selecting Selecting Selecting None of Them When is selected Emphasis on intensity is placed upon the red side while treating both sides alternately Emphasis on intensity...

Page 8: ...atteries The supplied batteries are for the trial use only and may wear out in less than three months Replace the worn batteries with new ones immediately If you are not going to use the unit for more...

Page 9: ...he region you want to receive treatment Discard the peeled off clear film as it should not be used anymore Attach the Pads close to the skin If the Pads comes off from the skin the unit is turned off...

Page 10: ...to the shaded regions of calf as shown in the diagram It is effective to attach the Pads to the shaded regions of lower back as shown in the diagram This section explains the treatment procedure and t...

Page 11: ...the power is turned off The power will be turned off automati cally in approxi mately 15 minutes after the treatment starts Even when the power is turned off automatically turn off the Intensity Dial...

Page 12: ...NERVE STIMULATOR P P M 1 2 3 4 5 2 3 4 5 6 7 8 9 When Shoulder is selected How to use the Special Mode You can use this Mode when you want to adjust the stimulation to your favourite one according to...

Page 13: ...on A blinking yellow light indicates the function you have selected Treat an area by selecting one of the programmes within Relief Region or Massage Treat an area with the button When you want to trea...

Page 14: ...It may cause the adhesive surface to be damaged Keep the Electrode Holder clean 4 Bundle the Electrode Cord and wrap it around the Electrode Holder Wrap the Electrode Cord loosely 5 Store the Main Uni...

Page 15: ...idity and direct sunshine or where there is a lot of dust and or corrosive gas Keep the unit out of reach of children If you are not going to use the unit for more than three months store the unit aft...

Page 16: ...shing allow the pads sufficient time for drying Replace the pads with new ones The stimulating effect cannot be felt The pads may have been used while perspiring The pads may have been washed too long...

Page 17: ...n Recommendation is to keep a minimum distance of 7 m Verify correct operation of the device in case the distance is shorter Further documentation in accordance with EN60601 1 2 2007 is available at O...

Page 18: ...atteries Battery Life New alkaline battery will last for approx 3 months when used for 15 minutes day con tinuously Note Supplied battery is for trial use This battery may run out within 3 months Freq...

Reviews: