background image

1

E2AG

Cylindrical Proximity Sensor

E2AG

• Highest value-performance ratio for standard applications
• Shielded and unshielded models with standard sensing range

Ordering information

Note:

Add the cable length to the model number (example: E2AG-M12KS02-WP-B1 2M).

Appearance

Sensing distance

Output

Type

Operation mode NO

Operation mode NC

Shielded

M8

PNP

E2AG-S08KS01-WP-B1

E2AG-S08KS01-WP-B2

M12

E2AG-M12KS02-WP-B1

E2AG-M12KS02-WP-B2

M18

E2AG-M18KS05-WS-B1

E2AG-M18KS05-WS-B2

M30

E2AG-M30KS10-WS-B1

E2AG-M30KS10-WS-B2

Unshielded

M8

PNP

E2AG-S08KN02-WP-B1

E2AG-S08KN02-WP-B2

M12

E2AG-M12KN05-WP-B1

E2AG-M12KN05-WP-B2

M18

E2AG-M18KN10-WS-B1

E2AG-M18KN10-WS-B2

M30

E2AG-M30KN18-WS-B1

E2AG-M30KN18-WS-B2

1.5 mm

2 mm

5 mm

10 mm

2 mm

5 mm

10 mm

1

8

 mm

Summary of Contents for E2AG

Page 1: ...sing distance Output Type Operation mode NO Operation mode NC Shielded M8 PNP E2AG S08KS01 WP B1 E2AG S08KS01 WP B2 M12 E2AG M12KS02 WP B1 E2AG M12KS02 WP B2 M18 E2AG M18KS05 WS B1 E2AG M18KS05 WS B2...

Page 2: ...mm 6 Kind of connection WP pre wired PVC dia 4 mm WS pre wired PVC dia 6 mm 7 Power Source and Output B DC 3 wire PNP open collector 8 Operation mode 1 Normally open NO 2 Normally closed NC 9 Cable l...

Page 3: ...le p p 10 max 10 30 VDC Current consumption 13 mA max Control output Load current open collector 200 mA max Residual voltage 2 V max under load current of 200 mA with cable length of 2 m Indicator Ope...

Page 4: ...10 C B E2AG M18KS05 C B E2AG M12KS02 C B E2AG S08KS01 C B Distance X mm Distance Y mm E2AG M30KN18 C B E2AG S08KN02 C B E2AG M12KN05 C B E2AG M18KN10 C B Distance X mm Distance Y mm E2AG S08KS01 C B D...

Page 5: ...g object d mm Iron Iron Stainless steel Stainless steel Brass Brass Aluminum Aluminum Copper Distance X mm Distance X mm Iron Stainless steel Aluminum E2AG M18KN10 C B E2AG M30KN18 C B Side length of...

Page 6: ...VC round insulated cable 3 wire dia 4 cross section of conductor 0 3mm insulator diameter 1 3mm standard 2m cable indicator 1 2 clamping nuts toothed washer 1 PVC round insulated cable 3 wire dia 4 cr...

Page 7: ...e Incorrect connection Ensure that the power suppy polarity and other wiring is correct oth erwise incorrect wiring may cause explosion or burning Output Model Operation mode Timing chart Output circu...

Page 8: ...8 Cylindrical Proximity Sensor In the interest of product improvement specifications are subject to change without notice Cat No E61E EN 01...