background image

D-158

Inductive Sensors

M12 Connector Models (Shielded)

E2AU-M12KS04-M1-

@@

E2AU-M18KS08-M1-

@@

7

4

34

48

17

M12

×

1

M12

×

1

10

24

4

39

53

M18

×

1

M12

×

1

E2AU-M30KS15-M1-

@@

44

5

58

36

10

M30

×

1.5

M12

×

1

Note 1:

Operation indicator (yellow LED, 4

×

90

°

)

Note:

Operation indicator (yellow LED, 4

×

90

°

)

Note:

Operation indicator (yellow LED, 4

×

90

°

)

Two, clamping nuts

Indicator (See note.)

Two, clamping nuts

Indicator (See note.)

Two, clamping nuts

Indicator (See note.)

7

4

56

70

17

M12

×

1

M12

×

1

10

24

4

61

75

M18

×

1

M12

×

1

66

5

80

36

10

M30

×

1.5

M12

×

1

Note:

Operation indicator (yellow LED, 4

×

90

°

)

Note:

Operation indicator (yellow LED, 4

×

90

°

)

Note:

Operation indicator (yellow LED, 4

×

90

°

)

E2AU-M12LS04-M1-

@@

E2AU-M18LS08-M1-

@@

E2AU-M30LS15-M1-

@@

Two, clamping nuts

Indicator (See note.)

Two, clamping nuts

Indicator (See note.)

Two, clamping nuts

Indicator (See note.)

D10E-EN-01+E2AU+Datasheet.fm  Seite 158  Donnerstag, 12. Juni 2008  11:21 11

Summary of Contents for E2AU -

Page 1: ...length Output configuration Operation mode NO M12 Shielded 4 0 mm Pre wired Brass 34 50 PNP E2AU M12KS04 WP B1 2M 56 72 PNP E2AU M12LS04 WP B1 2M M12 connector Brass 34 48 PNP E2AU M12KS04 M1 B1 56 7...

Page 2: ...e g 02 2 mm 16 16 mm 8 Kind of connection WP pre wired PVC dia 4mm standard WS pre wired PVC dia 6mm WR pre wired PVC robotic cable dia 4mm WA pre wired PUR PVC PUR jacket dia 4mm WB pre wired PUR PV...

Page 3: ...g object approaching B1 Protection circuit Output reverse polarity protection Power source circuit reverse polarity protection Surge suppressor Short circuit protection Ambient air temperature Operati...

Page 4: ...ect approaching B1 Protection circuit Output reverse polarity protection Power source circuit reverse polarity protection Surge suppressor Short circuit protection Ambient air temperature Operating 40...

Page 5: ...5 0 1 0 2 0 3 0 4 0 5 0 7 0 8 0 6 0 10 20 30 40 50 60 d t 1 mm X 0 4 8 12 16 20 10 20 30 40 50 60 70 80 d t 1 mm X Side length of sensing object d mm Brass Iron Sensing distance X mm Stainless steel S...

Page 6: ...distance Sensing zone Non sensing zone Proximity Sensor ON OFF ON OFF Yellow indicator Control output 3 1 2 4 Load Brown Black See note 1 Blue V 0 V Note 1 With M8 connector models there is no output...

Page 7: ...diameter 1 3 mm standard length 2 m 2 Operation indicator yellow Indicator See note 2 M12 1 17 72 3 56 7 4 M18 1 24 81 5 61 10 4 5 10 86 5 66 36 M30 1 5 See note 1 See note 1 See note 1 E2A M12LS04 WP...

Page 8: ...yellow LED 4 90 Two clamping nuts Indicator See note Two clamping nuts Indicator See note Two clamping nuts Indicator See note 7 4 56 70 17 M12 1 M12 1 10 24 4 61 75 M18 1 M12 1 66 5 80 36 10 M30 1 5...

Page 9: ...to the load Effects of Surrounding Metal When mounting the E2AU within a metal panel ensure that the clearances given in the following table are maintained Unit mm Note 1 In the case of using the supp...

Page 10: ...ir the Sensor Environment Water Resistivity The Proximity Sensors are tested intensively on water resistance but in order to ensure maximum performance and life expectancy avoid immersion in water and...

Reviews: