background image

E2E-

@

Y/E2F-

@

Y

     1

Cylindrical Inductive Sensor for AC Power Supply

E2E-

@

Y/E2F-

@

Y

• 24 to 240 VAC power supply voltage
• brass or plastic housing 

(M8 in SUS housing)

Ordering Information

Plastic Housing

AC 2-wire/Pre-wired Models

Metal Housing

AC 2-wire/Pre-wired Models

AC 2-wire/Connector Models

Size

Sensing 

distance

Model

Operating status

 NO

NC

Shielded

M8

1.5 mm

E2F-X1R5Y1

*1

*1. A different frequency type is available (E2F-X

@@

5; e.g. E2F-X5E15)

E2F-X1R5Y2

*1

M12

2 mm

E2F-X1Y1

*1

E2F-X2Y2

*1

M18

5 mm

E2F-X5Y1

*1*2

E2F-X5Y2

*1*2

M30

10 mm

E2F-X10Y1

*1*2

E2F-X10Y2

*1*2

*2. A short-circuit protection type is available (E2F-X

@

Y

@

-53; 

e.g. E2F-X5Y1-53) Power Supply Voltage: 100 to 120 VAC

Size

Sensing 

distance

Operation 

mode

Model

Shielded

M8

1.5 mm

NO

E2E-X1R5Y1

NC

E2E-X1R5Y2

M12

2 mm

NO

E2E-X2Y1

*1*2

*1. Models with a different frequency are also available. These models are

E2E-X

@

Y

@

5 (e.g., E2E-X5Y15).

*2. Cables with a length of 5 m are also available. Specify the cable length at

the end of the model number (e.g., E2E-X2Y1 5M).

NC

E2E-X2Y2

M18

5 mm

NO

E2E-X5Y1

*1*2

NC

E2E-X5Y2

M30

10 mm

NO

E2E-X10Y1

*1*2

NC

E2E-X10Y2

Un-
shielded

M8

2 mm

NO

E2E-X2MY1

NC

E2E-X2MY2

M12

5 mm

NO

E2E-X5MY1

*1*2

NC

E2E-X5MY2

M18

10 mm

NO

E2E-X10MY1

*1

NC

E2E-X10MY2

M30

18 mm

NO

E2E-X18MY1

*1

NC

E2E-X18MY2

Size

Sensing 

distance

Operation 

mode

Model

Shielded M12

2 mm

NO

E2E-X2Y1-M1

NC

E2E-X2Y2-M1

M18

5 mm

NO

E2E-X5Y1-M1

NC

E2E-X5Y2-M1

M30

10 mm

NO

E2E-X10Y1-M1

NC

E2E-X10Y2-M1

Un-
shielded

M12

5 mm

NO

E2E-X5MY1-M1

NC

E2E-X5MY2-M1

M18

10 mm

NO

E2E-X10MY1-M1

NC

E2E-X10MY2-M1

M30

18 mm

NO

E2E-X18MY1-M1

NC

E2E-X18MY2-M1

Summary of Contents for E2E-X10MY1

Page 1: ...ce Operation mode Model Shielded M8 1 5 mm NO E2E X1R5Y1 NC E2E X1R5Y2 M12 2 mm NO E2E X2Y1 1 2 1 Models with a different frequency are also available These models are E2E X Y 5 e g E2E X5Y15 2 Cables with a length of 5 m are also available Specify the cable length at the end of the model number e g E2E X2Y1 5M NC E2E X2Y2 M18 5 mm NO E2E X5Y1 1 2 NC E2E X5Y2 M30 10 mm NO E2E X10Y1 1 2 NC E2E X10Y...

Page 2: ...ne 2 2 Short circuit protection types are available Ambient temperature Operating Storage 25 C to 70 C with no icing or condensation Ambient humidity Operating Storage 35 to 95 RH Temperature influence A maximim fluctuation of 10 max of sensing distance at 23 C in the temperature range of 25 C to 70 C Voltage influence 1 max of sensing distance within a range of 10 of rated power supply voltage In...

Page 3: ... NO Y2 Models NC For details refer to Timing Charts Protection circuit Surge suppressor Ambient temperature 1 2 Operating Storage 25 C to 70 C with no icing or condensation Operating Storage 40 C to 85 C with no icing or condensation Ambient humidity Operating Storage 35 to 95 with no condensation Temperature influence 10 max of sensing distance at 23 C in the temperature range of 25 C to 70 C 15 ...

Page 4: ...5Y1 E2F X2Y1 E2F X5Y1 E2F X10Y1 E2E Y1 NC E2F X1R5Y2 E2F X2Y2 E2F X5Y2 E2F X10Y2 E2E Y2 Operation mode Applicable models Pin arrangement NO E2E X Y1 M1 NC E2E X Y2 M1 Yes No Operates Releases ON OFF Sensing object Load Detection indicator Main circuit Load Brown Blue Yes No Operates Releases ON OFF Sensing object Load Detection indicator Note Terminals 1 and 2 are not used Load Load Note Terminals...

Page 5: ...ensing distance X mm X Y 30 25 20 15 10 5 0 30 20 10 0 10 20 30 Distance Y mm E2E X18M E2E X10M E2E X5M E2E X2M Sensing distance X mm X Y E2E X Y Leakage current mA Supply voltage V Proximity Sensor when OFF Protective resistance AC power supply E2F X Y Power supply voltage V Proximity Sensor OFF Protective resistance AC power supply 50 60 Hz Leakage current mA E2F XjYj ...

Page 6: ...um Iron Brass Aluminum Side length of sensing object d mm Side length of sensing object d mm Stainless steel SUS304 Stainless steel SUS304 Sensing distance X mm Sensing distance X mm E2E X Y Load current mA Load voltage V L V Load current mA Load current mA Residual output voltage Residual load voltage Proximity Sensor 24 VAC 100 VAC Residual output voltage Residual load voltage Proximity Sensor R...

Page 7: ...inless steel SUS304 E2E X10Y E2F X10Y E2E X2MY E2E X5MY E2E X10MY E2E X18MY Sensing distance mm Side length of sensing object d mm Sensing distance mm Side length of sensing object d mm Sensing distance mm Sensing distance mm Side length of sensing object d mm Side length of sensing object d mm Sensing distance mm Side length of sensing object d mm Iron Stainless steel SUS304 Brass Aluminum t 1 mm...

Page 8: ...e E2F X 5 that is operating at a different frequency E2E X Y E2F X Y AC 2 wire Models Blue Load Load Brown Brown Blue Power supply Power supply Note The load can be connected as shown above Model Part A Part B Length Torque Torque M8 Shielded 9 mm 9 N m 12 N m Unshielded 3 mm M12 30 N m M18 70 N m M30 180 N m Model l d D m n E2E X Y AC 2 wire Shielded M8 0 mm 8 mm 0 mm 4 5 mm 12 mm M12 0 mm 12 mm ...

Page 9: ...Although the Proximity Sensor has a surge absorption circuit if there is any machine that has a large surge current e g a motor or weld ing machine near the Proximity Sensor connect a surge absorber to the machine Leakage Current When the Proximity Sensor is OFF the Proximity Sensor has leak age current Refer to 5 and 6 Leakage Current Characteristics In this case the load is imposed with a small ...

Page 10: ...rallel In this case however due to the total leakage current of the Proximity Sensors the load may not reset properly It is not possible to keep the load operating continuously with Proximity Sensors A and B in simultaneous operation to sense sensing objects due to the following reason When Proximity Sensor A is ON the voltage imposed on Proximity Sensor A will drop to approximately 10 V and the l...

Page 11: ...Oil and vibration resistant vinyl insulated round cord 6 dia 0 5 dia x 2 cores Standard length 2 m The cord can be extended up to 200 m in an independent metal conduit Note Oil and vibration resistant vinyl insulated round cord 6 dia 0 5 dia x 2 cores Standard length 2 m The cord can be extended up to 200 m in an independent metal conduit Note Oil and vibration resistant vinyl insulated round cord...

Page 12: ...eter 1 3 mm Standard length 2 m The cable can be extended up to 200 m separate metal conduit 6 dia vinyl insulated round cable with 2 conductors D Y T Models Conductor cross section 0 5 mm2 Insulator diameter 1 9 mm Standard length 2 m Note Operation indicator red Note Operation indicator red 6 dia vinyl insulated round cable with 2 conductors Conductor cross section 0 5 mm2 Insulator diameter 1 9...

Page 13: ...4 17 38 10 53 M12 1 M12 1 Operating indicator red Toothed washer Two clamping nuts 21 dia 9 dia 4 7 17 38 10 53 M12 1 M12 1 Operation indicator red Toothed washer Two clamping nuts 29 dia 4 24 38 10 53 M18 1 M12 1 Indicator See note Two clamping nuts Toothed washer 29 dia 14 8 dia 4 10 24 38 10 53 M18 1 M12 1 Indicator See note Toothed washer Two clamping nuts 42 dia 5 36 43 10 58 M30 1 5 M12 1 In...

Page 14: ... PRODUCTS CONTAINED IN THIS CATALOG ARE NOT SAFETY RATED THEY ARE NOT DESIGNED OR RATED FOR ENSURING SAFETY OF PERSONS AND SHOULD NOT BE RELIED UPON AS A SAFETY COMPONENT OR PROTECTIVE DEVICE FOR SUCH PURPOSES Please refer to separate catalogs for OMRON s safety rated products OMRON shall not be responsible for conformity with any standards codes or regulations that apply to the combination of pro...

Reviews: