background image

A-7

E2FM

E2FM

Safety Precautions

This product is not designed or rated for ensuring

safety of persons. Do not use it for such purposes.

Never use this product with an AC power supply.

Otherwise, explosion may result.

The following precautions must be observed to ensure safe 

operation.

1. Do not use the Sensor in an environment where 

inflammable or explosive gas is present.

2. Do not attempt to disassemble, repair, or modify any 

Sensors.

3. Power Supply Voltage

Do not use a voltage that exceeds the rated operating 
voltage range. Applying a voltage that is higher than the 
operating voltage range may result in explosion or fire.

4. Incorrect Wiring

Be sure that the power supply polarity and other wiring is 
correct. Incorrect wiring may cause explosion or fire.

5. Connection without a Load

If the power supply is connected directly without a load, the 
internal elements may explode or burn. Be sure to insert a 
load when connecting the power supply.

Do not use the Sensor under ambient conditions that exceed

the ratings to ensure maximum lifetime:

1. Please do not use the Sensor in the following locations. 

(1) Outdoor locations directly subject to sunlight, rain, snow, or 

water droplets

(2) Locations subject to atmospheres with chemical vapors, in 

particular solvents and acids 

(3) Locations subject to corrosive gas

2. The Sensor may malfunction if used near ultrasonic cleaning 

equipment, high-frequency equipment, transceivers, cellular 
phones, inverters, or other devices that generate a high-frequency 
electric field. Refer to the 

Sensor General Catalog

 for typical 

measures.

3. Laying the Sensor wiring in the same conduit or duct as high-

voltage wires or power lines may result in incorrect operation and 
damage due to induction. Wire the Sensor using a separate 
conduit or independent conduit.

4. Cleaning

Never use thinner or other solvents. Otherwise, the Sensor surface 
may be dissolved.

Design

Influence of Surrounding Metal

When the Proximity Sensor is embedded in metal, make sure

that the clearances given in the following table are main-

tained. The values depend on the type of nuts used for mount-

ing. Be sure to use the supplied nuts (SUS303).

(Unit: mm)

Note: The influence from other non-magnetic surrounding metals is nearly the

same as that from aluminum.

Mutual Interference

When installing two or more Sensors face-to-face or side-by-

side, ensure that the minimum distances given in the following

table are maintained.

Chips from Cutting Aluminum or Cast Iron

Normally, chips from cutting aluminum or cast iron will not

cause a detection signal to be output even if it adheres to or

accumulates on the detection surface. In the following cases,

however, a detection signal may be output. Remove the cut-

ting chips in these cases.

Mounting

Do not tighten the nut with excessive force. A washer must be

used with the nut. Do not use tightening force that exceeds the

values in the following table. 

WARNING

Precautions for Safe Use

Precautions for Correct Use

l

D

d dia.

l

m

n

Item

l

d

D

m

n

Model

Embedding

material

E2FM-X1R5

@

Iron

0

8

0

4.5

30

Aluminum

10

50

10

4.5

50

E2FM-X2

@

Iron

0

12

0

8

40

Aluminum

16

70

16

8

70

E2FM-X5

@

Iron

0

18

0

20

60

Aluminum

16

80

16

20

80

E2FM-X10

@

Iron

0

30

0

40

100

Aluminum

24

120

24

40

120

A

B

(Unit: mm)

Model

Item

A

B

E2FM-X1R5

@

35

30

E2FM-X2

@

40

35

E2FM-X5

@

65

60

E2FM-X10

@

110

100

1. If d 

D at the center of the 

detection surface where d is the 
cutting chip size and D is the 
detection surface size

Model

Dimension 

(mm)

D

E2FM-X1R5

@

6

E2FM-X2

@

10

E2FM-X5

@

16

E2FM-X10

@

28

2
3

d

D

Detection surface

Cutting chip

Cutting chips

Pressed down

Model

Torque

E2FM-X1R5

@

9 N·m

E2FM-X2

@

30 N·m

E2FM-X5

@

70 N·m

E2FM-X10

@

180 N·m

Summary of Contents for E2FM -

Page 1: ...ge Application Full body stainless steel housing with 0 8 mm thick sensing face protection 0 8 mm The stainless steel head shows minimal wear when cleaned with a metal brush More than 20 times the durability of standard sensors Brush Test E2FM Standard sensor Continuous Impact Test Standard sensor E2FM The standard sensor with top wall thickness of 0 2 mm was pene trated after 10 000 impacts The E...

Page 2: ...FM X2D1 M1GJ No polarity No Pin allocations 3 4 E2FM X2D1 M1GJ T M18 Polarity Yes Pin allocations 1 4 E2FM X5D1 M1GJ No polarity No Pin allocations 3 4 E2FM X5D1 M1GJ T M30 Polarity Yes Pin allocations 1 4 E2FM X10D1 M1GJ No polarity No Pin allocations 3 4 E2FM X10D1 M1GJ T Appearance Sensing distance Output configuration Operation mode Model Shielded M8 DC 3 Wire PNP NO E2FM X1R5B1 M1 M12 E2FM X2...

Page 3: ...m 5 V max Load current 100 mA Cable length 2 m Indicators Operation indicator red LED Setting Operation indicator green LED Operation mode with sensing object approaching NO Protection circuits Surge suppressor Load short circuit protection Ambient temperature range Operating Storage 25 to 70 C with no icing or condensation Ambient humidity range Operating Storage 35 to 95 with no condensation Tem...

Page 4: ...hing NO Protection circuits Reversed power supply polarity protection Surge suppressor Load short circuit protection and Reversed out put polarity protection except the E2FM X1R5B1 M1 Ambient temperature range Operating Storage 25 to 70 C with no icing or condensation Ambient humidity range Operating Storage 35 to 95 with no condensation Temperature influence 20 max of sensing distance at 23 C in ...

Page 5: ...Aluminum Brass Copper Stainless steel SUS304 Side length of sensing object d mm 7 6 5 4 3 2 1 0 0 20 40 60 80 Distance X mm Stainless steel SUS304 Iron Brass Aluminum Copper Side length of sensing object d mm 12 10 8 6 4 2 0 0 10 20 30 40 50 60 80 90 70 Distance X mm Side length of sensing object d mm Stainless steel SUS304 Iron Brass Aluminum Copper E2FM X1R5D1 M1GJ 1 0 0 8 0 6 0 4 0 2 0 0 0 5 10...

Page 6: ...d to either the V or 0 V side Load 12 to 24 VDC Connector Pin Arrangement Note Pins 2 and 3 are not used 4 3 Proximity sensor main circuit 12 to 24 VDC Load Connector Pin Arrangement Note Pins 1 and 2 are not used 0 V 12 to 24 VDC Note 1 The load can be connected to either the V or 0 V side 2 The E2FM X 1 M1GJ T has no polarity There is no need to be concerned about the polarity of pins 3 and 4 10...

Page 7: ...uction Wire the Sensor using a separate conduit or independent conduit 4 Cleaning Never use thinner or other solvents Otherwise the Sensor surface may be dissolved Design Influence of Surrounding Metal When the Proximity Sensor is embedded in metal make sure that the clearances given in the following table are main tained The values depend on the type of nuts used for mount ing Be sure to use the ...

Page 8: ...00 mm 2 Operation indicator red green Setting indicator green E2FM X5D1 M1GJ E2FM X5D1 M1GJ T 36 63 5 49 43 5 10 M30 1 5 42 dia Toothed washer Two clamping nuts Indicator 2 1 M12 1 1 6 dia vinyl insulated round cable flame retardant Standard length 300 mm 2 Operation indicator red green Setting indicator green E2FM X10D1 M1GJ E2FM X10D1 M1GJ T 4 5 13 25 30 34 5 53 5 15 dia Two clamping nuts Toothe...

Page 9: ...isted may be suitable for the products Outdoor use uses involving potential chemical contamination or electrical interference or conditions or uses not described in this document Nuclear energy control systems combustion systems railroad systems aviation systems medical equipment amusement machines vehicles safety equipment and installations subject to separate industry or government regulations S...

Page 10: ... the interest of product improvement specifications are subject to change without notice Cat No D104 E2 01 X OMRON EUROPE B V Wegalaan 67 69 NL 2132 JD Hoofddorp The Netherlands Phone 31 23 568 13 00 Fax 31 23 568 13 88 www eu omron com ...

Reviews: