background image

3

E2FQ

Output Circuit Diagram

Precautions

Design

Effects of Surrounding Metal

Provide a minimum distance  between the Sensor and the

surrounding metal as shown in the table below.

Effects of Surrounding Metal

(Unit: mm)

Mutual Interference

If more than one Proximity Sensor is installed face to face or

in parallel, ensure that the distances between two Units adja-

cent to each other are the same as or larger than the corre-

sponding values shown in the following table.

Installation

Do not tighten the nut with excessive force. A washer must be

used with the nut.

Note: The table below shows the value of tightening torques when using

toothed washers.

Others

Chemical resistance

Operating 

status

Output 

specifications

Model

Timing chart

Output circuit

NO

PNP

E2FQ-X

@

F1

NPN

E2FQ-X

@

E1

DC 2-wire

E2FQ-X

@

D1

Yes

No

Operates

Releases

H

L

Load 
(between black 
and blue leads)
Output voltage 
(between black 
and blue leads)

Sensing 
object

ON

OFF

Operation 
indicator

Brown

Black

Output

Blue

100

W

4.7k

W

2.2

W

Main 
circuit

+V

0V

Load

Yes

No

Operates

Releases

H

L

Load 
(between black 
and blue leads)
Output voltage 
(between black 
and blue leads)

Sensing 
object

ON

OFF

Operation 
indicator

Brown

Black

Output

Blue

100

W

4.7k

W

2.2

W

Main 
circuit

+V

0V

(see note 2)

(see note 1)

Tr

Note:
1. 200 mA max.(load current)
2. When a transistor is connected

Load

Operation 
indicator

Operates

Releases

ON

OFF

Load

Sensing 
object

Yes

No

Load

Brown

Blue

Main 
circuit

+V

0V

Note:
The load can be connected to 
either the +V or the 0-V line.

Correct Use

Model

Item

l

d

D

m

n

E2FQ-X2

#

0

12

0

8

18

E2FQ-X5

#

18

20

27

E2FQ-X10

#

30

40

45

l

m

n

l

m

D

d dia.

Model

Torque

Tensile strength 

(torque)

E2FQ-X2

#

0.98 Nm

E2FQ-X5

#

2 Nm

E2FQ-X10

#

A

B

Mutual Interference

(Unit: mm)

Model

Item

A

B

E2FQ-X2

#

30

20

E2FQ-X5

#

50

35

E2FQ-X10

#

100

70

Summary of Contents for E2FQ

Page 1: ...Q X5D1 500 Hz M30 E2FQ X10F1 E2FQ X10E1 400 Hz E2FQ X10D1 300 Hz Shielded 2mm 5mm 10mm E2FQ X2 E2FQ X5 E2FQ X10 Side length of sensing object d mm Sensing distance X mm 0 5 10 15 20 25 2 4 2 2 2 1 8 1 6 1 4 1 2 1 0 8 0 6 0 4 0 2 Aluminum Stainless steel SUS304 Mild steel Brass d t 1mm X Side length of sensing object d mm Sensing distance X mm 0 5 10 15 20 25 30 35 40 50 7 6 5 4 3 2 1 Aluminum Stai...

Page 2: ...nt 200 mA with cable length 2 m D1 models 4 0 V max under load current of 100 mA with cable length of 2 m Indicator lamp E D models detection indicator red Operating status with sensing object approaching Normally open NO Protective circuits E1 F1 models Protection for reverse polarity load short circuit surge voltage Ambient temperature Operating Storage 25 C to 70 C with no icing or condensation...

Page 3: ... DC 2 wire E2FQ X D1 Yes No Operates Releases H L Load between black and blue leads Output voltage between black and blue leads Sensing object ON OFF Operation indicator Brown Black Output Blue 100W 4 7kW 2 2W Main circuit V 0V Load Yes No Operates Releases H L Load between black and blue leads Output voltage between black and blue leads Sensing object ON OFF Operation indicator Brown Black Output...

Page 4: ... can be extended in an independent conduit for 200 m maximum E2FQ X5E1 E2FQ X5F1 29 dia 40 47 32 29 24 8 M18 x 1 Two Toothed washers Two clamping nut Indicator see note Note Oil resistant vibration resistant and fire retardant vinyl insulated round cord 6 dia x 2 cores standard length 2 m The cord can be extended in an independent conduit for 200 m maximum E2FQ X5D1 42 dia 36 57 50 41 38 8 M30 x 1...

Page 5: ...suitable for the products Outdoor use uses involving potential chemical contamination or electrical interference or conditions or uses not described in this document Nuclear energy control systems combustion systems railroad sys tems aviation systems medical equipment amusement machines vehicles safety equipment and installations subject to separate in dustry or government regulations Systems mach...