background image

L

iquid

 L

evel

 S

ensor

E2K-L 

A

vailable

 

in

 8 

to

 11-

mm

-

dia

and

 12 

to

 26-

mm

-

dia

.

models

 

to

 

enable

 

sensing

 

for

 

a

 

w ide

 

range

 

of

 

pipe

 

diameters

S

enses

 

by

 

electrostat ic

 

capacity

 

and

 

is

 

not

 

influenced

 

by

 

the

 

color

 

of

 

the

 

pipe

 

or

 

liquid

.

8 to 11 mm

12 to 26 mm

OMRON  C

orporation

I

ndustrial

 A

utomat ion

 C

ompany

Industrial Sensors Division

Sensing Devices and Components Division H.Q.
Shiokoji Horikawa, Shimogyo-ku, 
Kyoto, 600-8530 Japan
Tel : (81)75-344-7068 / Fax : (81)75-344-7107

Regional Headquarters

OMRON EUROPE B.V.

Sensor Business Unit
Carl-Benz-Str. 4, D-71154 Nufringen, 
Germany
Tel : (49)7032-811-0 / Fax : (49)7032-811-199

OMRON ELECTRONICS LLC

1 East Commerce Drive, Schaumburg, IL 60173 
U.S.A.
Tel : (1)847-843-7900 / Fax : (1)847-843-8568

OMRON ASIA PACIFIC PTE. LTD.

83 Clemenceau Avenue, 
#11-01, UE Square, 
239920 Singapore
Tel : (65)835-3011 / Fax : (65)835-2711

OMRON CHINA CO., LTD. 

BEIJING OFFICE
Room 1028, Office Building, 
Beijing Capital Times Square,
No.88 West Chang'an Road, 
Beijing, 100031 China
Tel : (86)10-8391-3005 / Fax : (86)10-8391-3688

Cat. No. D094-E1-1

Note:Specifications subject to change without notice.

0601-1M(0501)(G)

Authorized Distributor:

Summary of Contents for E2K-L

Page 1: ...4 7107 Regional Headquarters OMRON EUROPE B V Sensor Business Unit Carl Benz Str 4 D 71154 Nufringen Germany Tel 49 7032 811 0 Fax 49 7032 811 199 OMRON ELECTRONICS LLC 1 East Commerce Drive Schaumburg IL 60173 U S A Tel 1 847 843 7900 Fax 1 847 843 8568 OMRON ASIA PACIFIC PTE LTD 83 Clemenceau Avenue 11 01 UE Square 239920 Singapore Tel 65 835 3011 Fax 65 835 2711 OMRON CHINA CO LTD BEIJING OFFIC...

Page 2: ...ers allowing reductions in stock requirements Binding band Slip prevention tube 12 step sensitivity adjuster Operation indicator 20mm 24mm 33mm Little influence from bubbles Not influenced by the color of the pipe or liquid Use for pipes with diameters in the range 8 to 11 mm or 12 to 26 mm Conforms to CE standards Conforms to CE standards an indispensable requirement for semiconductor manufacturi...

Page 3: ... pipe or liquid Available in 8 to 11 mm dia and 12 to 26 mm dia models to enable sensing for a wide range of pipe diameters Space saved with built in amplifier Sensing method Applicable pipe diameters Appearance Output format Model number Electrostatic capacity method 8 to 11 mm dia NPN open collector output NO E2K L13MC1 12 to 26 mm dia E2K L26MC1 Liquid surface level detection ...

Page 4: ...on of liquid surface Notch position For details refer to Sensitivity Adjustment on page 6 Indicator Operation indicator orange Ambient temperature Operating 0 to 55 C Storage 10 to 65 C with no icing or condensation Ambient humidity Operating storage 25 to 85 with no condensation Temperature influence In the range 0 to 55 C Detection level at 23 C 4 mm with distilled water or 20 concentration salt...

Page 5: ...ence of Surrounding Objects Units mm Mutual Interference When installing 2 or more Sensors in series in parallel or facing each other be sure that they are separated by at least the distances shown below Mutual Interference Units mm The detection level for the top Sensor may change when the detection level for the bottom Sensor is set Be sure to set the detection level for the bottom Sensor first ...

Page 6: ...el to be detected After the Sensor is mounted adjust the detecting sensitivity using the 12 step sensitivity adjuster in the way shown below Note 1 While adjusting the sensitivity do not put your hand on the Sensor and make sure that the cable is properly secured Failure to observe these points may affect the detection level Note 2 When using more than one Sensor e g to detect for upper and lower ...

Page 7: ...s in temperature because this will shorten the service life Miscellaneous Drift may occur when the power supply is turned ON If the dielectric constant of the liquid is low the detection level of the liquid may be 2 to 3 mm higher than the set level for approximately 20 minutes after power is turned ON Dimensions Units mm Correct Use 20 5 43 41 33 R6 5 24 11 5 1 5 6 5 1 3 5 6 6 Sensitivity adjuste...