background image

Laser safety measures for laser equipment are stipulated by the country of use. Follow 

the instructions described below categorized in four cases.

・Usage in Japan

The JIS C6802:2014 standard stipulates the safety precautions that users must take 

according to the class of the laser product. This product is classified into class 1 defined 

by this standard.

・Usage in U.S.

This product is subjected to the U.S. FDA (Food and Drug Administration) laser 

regulations. This product is classified into Class 1 by the IEC 60825-1:2014 standard 

according to the regulations of Laser Notice No.56 of the FDA standard. This product is 

already reported to CDRH (Center for Devices and Radiological Health).

Accession Number: 1920014-001

When using a device equipped with the product in the U.S., attach an FDA certification 

label near the sensor mounted on customer equipment.

CMOS Laser Sensor

Thank you for selecting OMRON product. This sheet primarily describes precautions 

required in installing and operating the product.

Before operating the product, read the sheet thoroughly to acquire sufficient 

knowledge of the product. For your convenience, keep the sheet at your disposal.

Precautions for Correct Use

Package contents

Precautions for Safe Use

Please observe the following precautions for safe use of the products.

•Do not reverse connection of DC power supply polarity. Do not connect 

to AC power supply.

•Do not short-circuit the load.

•Never use this product with AC power supply. Otherwise it may 

explode.

•The maximum power supply voltage is 30 VDC. Before turning on the 

product's power, make sure that the supply voltage does not exceed 

the maximum power supply voltage.

•Do not use the product in environments where flammable or explosive 

gases are present.

•Please assess the safety beforehand when using the product in 

chemicals and/or oil environments.

•Do not remodel the product.

•Do not touch the metal surface with your bare hands when the 

temperature is low. Touching the surface may result in a cold burn.

•Burn injury may occur. The product surface temperature rises 

depending on application conditions, such as the ambient temperature 

and the power supply voltage. Attention must be paid during 

operation or cleaning.

•Do not hit the product using a hammer for installation.

•The product must be installed with the specified torque or less.

 For M8 connector and Pre-wired M8 connector, the proper tightening 

torque is from 0.3 to 0.4 N・m.

 In case of M12 Pre-wired smartclick connector, manually tighten the 

connector.

•Tightening torque for the mounting hole is 0.6 N・m or less (M3 screw).

•Do not use the product in ambient atmosphere or environment exceeding 

the rating.

•Output pulses may be generated when the power is turned off. It is 

recommended to turn off the power of the load or load line first.

•The extension of the cord under the standard I/O mode should be 100 m 

or less.Under the IO-Link mode, the length should be 20 m or less.

•Do not pull the cord too strongly.

•Be sure to turn off the power supply when connecting or disconnecting 

the cable.

•Wait for at least 600 ms after turning on the product's power.

•The product is rated as IP67 but please avoid using the product 

underwater, under rain, and outdoors.

•If the Sensor wiring is placed in the same conduits or ducts as high-voltage 

or high-power lines, inductive noise may cause malfunction or damage. 

Wire the cables separately or use a shielded cable.

•Do not use the product in direct sunlight.

•Do not use the product where humidity is high and dew condensation 

may occur.

•Do not use the product where corrosive gases may exist.

•Use a key lock to prevent malfunction if high-pressure wash water or other 

substances come into contact with the button.

• Do not apply high-pressure washing water directly to the sensor's light 

emitting / receiving surface from a short distance. As the antifouling 

feature may be impaired, keep a sufficient distance from the light emitting 

/ receiving surface.

•Do not use the product at a location subject to shock or vibration.

•To use a commercially available switching regulator, FG (frame ground) 

must be grounded.

•This product cannot be used as a detection device for human body 

protection.

•Do not use organic solvents (e.g. paint thinner and alcohol) for cleaning. 

Otherwise optical properties and protective structure may deteriorate.

•Be sure to check the influence caused by surrounding environments such 

as background objects and/or LED lighting before using the product.

•Do not exceed 100,000 writing operations of the EEPROM (non-volatile 

memory). Setting information is written to the EEPROM when a threshold 

value change, teaching, or zero reset is executed.

Instruction sheet (this sheet), Compliance sheet, Index list (attached for 
IO-Link type only), FDA certification label, Warning label

INSTRUCTION SHEET

Dispose in accordance with applicable regulations.

Indicates a potentially hazardous situation which, if not avoided, 

will result in minor or moderate injury, or may result in serious injury 

or death. Additionally there may be significant property damage.

This product is not designed or rated for ensuring safety of persons 

either directly or indirectly. Do not use it for such purpose.

WARNING

Do not use the product with voltage in excess of the rated voltage.

Excess voltage may result in malfunction or fire.

Indicates a potentially hazardous situation which, if not avoided, 

may result in minor or moderate injury or in property damage.

CAUTION

●Meaning of Signal Words

PRECAUTIONS ON SAFETY

To safely use laser products

Its component may be damaged and/or degree of protection may be degraded. 

Please do not apply high pressure water intensively at one place during cleaning.

WARNING

WARNING

CAUTION

FDA certification label

© OMRON Corporation  

2020

  All Rights Reserved. 

E3AS-HL150

/HL500

The following notice applies only to products that carry the CE mark.

Notice:

This is a Class A product. In residential areas it may cause radio 

interface, in which case the user may be required to be take adequate 

measures to reduce interference.

Looking into the Outgoing light continuously may cause visual impairment.

Do not look directly into the Outgoing light.

Caution-Use of controls or adjustments or performance of procedures other 

than those specified herein may result in hazardous radiation exposure

Attention-Lʼutilisation des commandes ou réglages ou lʼexécution des 

procédures autres que celles spécifiées dans les présentes exigences 

peuvent étre la cause dʼune exposition à un rayonnement dangereux
Do not disassemble this product.Doing so may cause exposure to 

the built-in light source which can damage eyes and skin. Never 

disassemble it.

Manufacturer:

  Omron Corporation,

  Shiokoji Horikawa, Shimogyo-ku,

  Kyoto 600-8530 JAPAN

TRACEABILITY INFORMATION:

Importer in EU:

  Omron Europe B.V.

  Wegalaan 67-69

  NL-2132 JD Hoofddorp,

  The Netherlands

Center of laser projection

Warning label

Model

* 5 6 3 0 5 3 9 - 9 A *

1

・Usage in China

This product is classified into Class 2 by the GB7247.1:2012(IEC60825-1:2007) standard.

When using a device equipped with the product in China, attach a Warning label near 

the sensor mounted on customer equipment.

・Usage in countries other than U.S. and China

This product is classified into Class 1 by the IEC/EN 60825-1:2014 standard.

Summary of Contents for E3AS-HL150 Series

Page 1: ...ccur Do not use the product where corrosive gases may exist Use a key lock to prevent malfunction if high pressure wash water or other substances come into contact with the button Do not apply high pr...

Page 2: ...he extension of the cord under the standard I O mode should be 100 m or less The extension of the cord in the IO Link mode should be 20 m or less Pre wired Models M12 Smartclick Connector Model M8 Con...

Page 3: ...t before zero reset execution Output after zero reset execution Output before zero reset execution Output after zero reset execution ON OFF Output1 Input Output1 Sensor response time Sensor response t...

Page 4: ...hing Object teaching Background reference teaching normal Background reference teaching sensitive 4 1 Basic Teaching page 5 4 1 Basic Teaching page 5 4 2 Advanced Teaching page 6 6 11 ABT Function pag...

Page 5: ...Background Threshold value Background reference surface Object This can be executed if setting Background when executing Teaching Selection in 6 Detailed Settings page 9 Background is the factory sett...

Page 6: ...output mode Threshold setting after teaching is completed Main screen after teaching is completed The threshold value is set with margin to the background Margin is set automatically to the optimal v...

Page 7: ...completed The unlocked icon is displayed on the main screen Setting completed The zero reset icon is displayed on the main screen Releasing completed The zero reset icon on the main screen is turned...

Page 8: ...Func Laser O TEACH T Laser O Teach Zero Reset Output 1 Logic 6 2 page10 UP DOWN Out1 Logic N O TEACH T N O N C Advanced Settings N Y Advanced Settings ON Advanced Settings OFF Advanced Settings ON UP...

Page 9: ...10page UP DOWN Interference Channel 1 TEACH T Channel 1 Channel 2 Channel 3 Channel 4 ABT Function 5 6 11 11page UP DOWN ABT Func 1sec TEACH T 1sec 0 3sec O 3min Unit mm reference Unit mm reference 6...

Page 10: ...e teaching sensitive is executed when output 1 mode Dist Int keeping is disabled The output when receiving light intensity is not su cient or detection has not been determined yet can be set 1 These a...

Page 11: ...Dist Int In the distance intensity mode user setup of hysteresis width is not allowed A xed value of 4 is always set Single Point Mode Single Window BGS mode Window BGS Window FGS mode Window FGS ON O...

Page 12: ...method E 3 A S H L M Note 1 Altitude Up to 2000m Pollution degree 3 Enclosure type Type1 1 Measured with OMRON s standard workpiece White ceramic 2 De ned by D4 method at the maximum sensing distance...