background image

1

E3F2-240VAC

Cylindrical photoelectric sensor with built-in power supply in M18 housing

E3F2-240VAC

• Easy installation by compact 

M18 housing

• Built-in power supply, suitable for 

24-240 VAC; no extra power supply 

needed

• Through-beam, Retro-reflective and 

diffuse-reflective types

Ordering information

Note: Standard cable length is 2 m. Models provided with a 5 m long cable are available. When ordering, specify the cable length by adapting the length of the cable 

(e.g. E3F2-R2Z1-E 5M). For other cable length please contact your OMRON sales representative.

Accessories (Order Separately)

For detailed information about Accessories, refer to the main chapter “Accessories” at the end of the document.

Sensing method

Sensing 
distance

Connection method

Order code

Light-ON

Dark-ON

Through-beam

3 m

2  m

E3F2-3Z1 2M

E3F2-3Z2 2M

Retro-reflective without M.S.R

*1

*1.

Order reflector seperately

0.1 to 2 m

*2

*2.

Measured with E39-R1

2  m

E3F2-R2Z1-E 2M

E3F2-R2Z2-E 2M

Diffuse-reflective wide beam

0.1 m (fixed)

2  m

E3F2-DS10Z1-N 2M

E3F2-DS10Z2-N 2M

Name

Sensing distance (typical)

Remark

Model

Reflectors

0.1 - 2 m

60 x 40 mm

E39-R1

0.1 - 3 m

 84 mm

E39-R7

0.1 - 4 m

100 x 100 mm

E39-R8

Mounting Bracket

screw mount

Y92E-B18

Summary of Contents for E3F2-240VAC

Page 1: ...length please contact your OMRON sales representative Accessories Order Separately For detailed information about Accessories refer to the main chapter Accessories at the end of the document Sensing...

Page 2: ...light 10000 lx max Ambient temperature Operating 25 to 55 C Storage 30 to 70 C with no icing or condensation Ambient humidity Operating 35 to 85 Storage 35 to 95 with no condensation Insulation resist...

Page 3: ...300 Distance Y mm Distance X m typical sensing distance 3 8 m X Y 1 2 3 4 5 6 0 0 100 200 300 100 200 300 Distance Y mm Distance X m 8 7 typical sensing distances E39 R1 3 4 m E39 R7 3 9 m E39 R8 5 2...

Page 4: ...Light ON E3F2 3Z2 E3F2 R2Z2 E3F2 DS10Z2 N ON when light is interrupted Dark ON Main circuit 24 to 240 VAC Brown Blue Power indicator red Incident Interrupted ON OFF ON OFF Operate Release Output indic...

Page 5: ...R2Z E3F2 DS10Z N Reflectors Installation E39 R1 E39 R1S E39 R8 E39 R7 16 8 dia 24 3 1 optical zone 22 90 67 3 62 M18 x 1 6g 5 dia 8 3 1 Light indicator Material reflective surface acrylic Rear surface...

Page 6: ...ct to direct sunlight Cleaning Do not use thinner alcohol or other organic solvents Otherwise the optical properties and degree of protection may be degraded Surface Temperature Burn injury may occur...

Page 7: ...7 E3F2 240VAC...

Page 8: ...isted may be suitable for the products Outdoor use uses involving potential chemical contamination or electrical interference or conditions or uses not described in this document Nuclear energy contro...