background image

E3F3

 

Photoelectric Sensor

 

1

Photoelectric Sensor

E3F3

Threaded Cylindrical Photoelec-
tric Sensor with Built-in Amplifi-
er for Use as an Optical 
Proximity Sensor
High Noise-immunity with 
Photo-IC Technology

• Up-to-date photo-IC to increase noise immunity.

• M18 DIN-sized cylindrical housing, ABS resin case.

• Long sensing distance (30 cm) with sensitivity adjus-

tor for diffuse type.

• Short-circuit and reverse connection protection.

<READ AND UNDERSTAND THIS CATALOG>
Please read and understand this catalog before 
purchasing the products. Please consult your 
OMRON representative if you have any questions or 
comments.

Ordering Information

 Infrared light

 Red light

Sensing 

method

Appearance

Connec-

tion meth-

od

Sensing distance

Operating modes

Model

Plastic housing

Metal housing

NPN output PNP output NPN output PNP output

Through-
beam

Pre-wired

Light-ON

E3F3-T11

E3F3-T31

E3F3-T11M E3F3-T31M

M12 CN

E3F3-T16

E3F3-T36

E3F3-T16M E3F3-T36M

Pre-wired

Dark-ON

E3F3-T61

E3F3-T81

E3F3-T61M E3F3-T81M

M12 CN

E3F3-T66

E3F3-T86

E3F3-T66M E3F3-T86M

Retrore-
flective

Pre-wired

Light-ON Non-po-

larized

E3F3-R11

E3F3-R31

E3F3-R11M E3F3-R31M

M12 CN

E3F3-R16

E3F3-R36

E3F3-R16M E3F3-R36M

Pre-wired

Dark-ON

E3F3-R61

E3F3-R81

E3F3-R61M E3F3-R81M

M12 CN

E3F3-R66

E3F3-R86

E3F3-R66M E3F3-R86M

Pre-wired

Light-ON Polarized E3F3-R12

E3F3-R32

E3F3-R12M E3F3-R32M

M12 CN

E3F3-R17

E3F3-R37

E3F3-R17M E3F3-R37M

Pre-wired

Dark-ON

E3F3-R62

E3F3-R82

E3F3-R62M E3F3-R82M

M12 CN

E3F3-R67

E3F3-R87

E3F3-R67M E3F3-R87M

Diffuse 
reflective

Pre-wired

Light-ON

E3F3-D11

E3F3-D31

E3F3-D11M E3F3-D31M

M12 CN

E3F3-D16

E3F3-D36

E3F3-D16M E3F3-D36M

Pre-wired

Dark-ON

E3F3-D61

E3F3-D81

E3F3-D61M E3F3-D81M

M12 CN

E3F3-D66

E3F3-D86

E3F3-D66M E3F3-D86M

Pre-wired

Light-ON

E3F3-D12

E3F3-D32

E3F3-D12M E3F3-D32M

M12 CN

E3F3-D17

E3F3-D37

E3F3-D17M E3F3-D37M

Pre-wired

Dark-ON

E3F3-D62

E3F3-D82

E3F3-D62M E3F3-D82M

M12 CN

E3F3-D67

E3F3-D87

E3F3-D67M E3F3-D87M

5 m

3 m

2 m

100 mm

300 mm

Summary of Contents for E3F3

Page 1: ...3 T11M E3F3 T31M M12 CN E3F3 T16 E3F3 T36 E3F3 T16M E3F3 T36M Pre wired Dark ON E3F3 T61 E3F3 T81 E3F3 T61M E3F3 T81M M12 CN E3F3 T66 E3F3 T86 E3F3 T66M E3F3 T86M Retrore flective Pre wired Light ON N...

Page 2: ...e and receiver 25 mA max Control output Open collector transistor output 100 mA max residual voltage 1 V max at 100 mA Protective circuit Output short circuit protection DC power supply reverse polari...

Page 3: ...Ratio vs Set Distance Typical Through beam Models E3F3 T 1 T 6 Retroreflective Models E3F3 R 1 R 6 E39 R1 Retroreflective Models E3F3 R 2 R 7 E39 R1 Excess gain ratio Excess gain ratio Excess gain ra...

Page 4: ...to 24 VDC Blue 1 4 3 Control output Load relay ON OFF Operate Incident light No incident light Operation indicator orange ON OFF Release Between brown and black 100 mA max control output Main circuit...

Page 5: ...4 42 4 37 4 5 M18 Sensitivity adjuster Operation indicator 4 dia See note 16 6 dia 24 27 7 E3F3 D 2M 73 1 49 4 42 4 37 8 4 5 M18 Sensitivity adjuster Operation indicator M12 16 6 dia 24 22 E3F3 D 7 73...

Page 6: ...tor 11 34 8 19 3 Two M3 2 6 1 2 34 38 41 8 10 1 25 4 0 1 1 2 Two M3 0 2 20 38 1 2 105 34 R25 4 16 Two 3 2 dia 11 20 0 2 0 2 145 13 7 29 3 4 R20 4 5 3 4 7 18 45 6 28 22 9 3 4 Adhesive side 25 4 Mountin...

Page 7: ...e the photoelectric sensor in the vicinity of an inverter motor be sure to connect the protective ground wire of the motor to ground Failure to ground the motor may result in malfunction of the sensor...

Page 8: ...aviation systems medical equipment amusement machines vehicles safety equipment and installations subject to separate industry or government regulations Systems machines and equipment that could prese...

Reviews: