background image

LIGHT STATUS

Green =

Power On &
Aim is Stable

Red =

 Unit “Sees”
the Reflector

Yellow =  Unit Does Not

“See” the
 Reflector

Normal

Unit thinks there
is an obstruction,
aim is off or the
reflector is bad.

In Dark On Mode

If unit is in Light On Mode,

the Red & Yellow LED’s

are the OPPOSITE.

Wiring

Sensitivity

Dark Switch

OMRON  E3K

 

Reflector Type Photo Eye

 

(24 to 240 VAC or VDC)

UL 325 Compliant

Instructions

Set Dark Switch to Dark ON.

Set Sensitivity near Max.

Wire Red & Black to Power.

Wire White to C1.

Wire Green to NO1.

Loosely Mount Photo Eye.

Solidly Mount Reflector, level
   with the Photo Eye’s Lens.

Tip Photo Eye Up & Down, Side
   to Side, until Red changes to
   Yellow to determine Horizontal
   & Vertical Center.  Tighten.