A - 27
A Appendices
E3NW-ECT EtherCAT Digital Sensor Communication Unit Operation Manual (E429)
A-
1 Object
Dictio
nary
A
A-1-7
Manufacturer
S
pecific
Obj
ec
ts
•
This object reads the peak detection level (amount of incident light) for the Sensor Amplifier with the
unit number that is specified by the index.
•
To read the peak detection level, you must set Display Mode to the smallest peak value of incident
light and the largest bottom value of interrupted light [P-b] or detection level at peak [PEAK].
•
The setting range of the FA
□
0, LA0, or SA0 is
−
1,999 to 9,999 (FFFFF831 to 0000270F hex).
•
The setting range of the AA
□
0 or VA
□
0 is
−
1999.9999 to 9999.9999.
* Items with asterisks are supported from E3NW-ECT version 1.03.
You can check the version with object index 100A hex. (Refer to "A-1-4 Communication Objects" on page A-4.)
•
This object reads the bottom detection level (amount of incident light) for the Sensor Amplifier with
the unit number that is specified by the index.
•
To read the peak detection level, you must set Display Mode to the smallest peak value of incident
light and the largest bottom value of interrupted light [P-b].
•
The setting range of the FA
□
0, LA0, or SA0 is
−
1,999 to 9,999 (FFFFF831 to 0000270F hex).
•
The setting range of the AA
□
0 or VA
□
0 is
−
1999.9999 to 9999.9999.
•
The setting range of VD0 is
−
9999 to 9999.
* Items with asterisks are supported from E3NW-ECT version 1.03.
You can check the version with object index 100A hex. (Refer to "A-1-4 Communication Objects" on page A-4.)
4002 + (N-1)
×
80
hex
No_01 ... 30 Peak Detection Level
Subindex 0: Number of Entries
Range: 02 hex
Unit: ---
Default: 02 hex
Attribute: ---
Size: 1 byte (U8)
Access: RO
PDO map: Not possible
Subindex 1: No_01 ... 30 Peak Detection Level IN1
Range:
−
2,147,483,648 to
2,147,483,647
(80000000 to 7FFFFFFF hex)
Unit: ---
Default: --- hex
Attribute: ---
Size: 4 bytes (INT32)
Access: RO
PDO map: Not possible
Subindex 2*: No_01 ... 30 Peak Detection Level IN2
Range:
−
2,147,483,648 to
2,147,483,647
(80000000 to 7FFFFFFF hex)
Unit: ---
Default: --- hex
Attribute: ---
Size: 4 bytes (INT32)
Access: RO
PDO map: Not possible
4003 + (N-1)
×
80
hex
No_01 ... 30 Bottom Detection Level
Subindex 0: Number of Entries
Range: 02 hex
Unit: ---
Default: 02 hex
Attribute: ---
Size: 1 byte (U8)
Access: RO
PDO map: Not possible
Subindex 1: No_01 ... 30 Bottom Detection Level IN1
Range:
−
2,147,483,648 to
2,147,483,647
(80000000 to 7FFFFFFF hex)
Unit: ---
Default: --- hex
Attribute: ---
Size: 4 bytes (INT32)
Access: RO
PDO map: Not possible
Subindex 2*: No_01 ... 30 Bottom Detection Level IN2
Range:
−
2,147,483,648 to
2,147,483,647
(80000000 to 7FFFFFFF hex)
Unit: ---
Default: --- hex
Attribute: ---
Size: 4 bytes (INT32)
Access: RO
PDO map: Not possible