4-4 Inputs/Outputs
19
4-4-2 Outputs
4-4-2-1
Switching output OUT
When a measured object is detected, the switching output OUT (Connector pin 4, fixed) switch in accordance
with the sensor's output function settings.
4-4-2-2
Alarm output ALARM
Connector pin 2 can be set as the alarm output. The alarm output is switched on if the intensity of reflected
light from the reflector is too low. In this case, the sensor may be covered with dust. Please clean the sensor
and check the alarm output again. This condition is indicated by the red LED too.