background image

E3X-DA-S

24

Nomenclature

Operating Procedure

Fiber Amplifier Units

E3X-DA

@F

-S (

@

: 21/51/7/9)

O

N

 

w

hen setting is O

N

OFF 

w

hen setting is OFF. 

Po

w

er t

u

ning  

indicator (orange) 

Easy key lock Selector 

Locks the fi

b

er 

u

nit

Incident le

v

el, f

u

nction, etc. 

Threshold, f

u

nction settings, etc. 

Use to select SET or RU

N

 Mode. 

F

u

nction setting 

operations 

UP 

DO

WN

 

MODE 

Select to lock or 

u

nlock settings. 

O

N

 

w

hen o

u

tp

u

t is O

N

OFF 

w

hen o

u

tp

u

t is OFF. 

Operation Indicator  
(orange) 

Lock le

v

er 

Main Display (Red) 

S

ub

-Display (Green) 

Mode Selector 

Operation Keys 

MODE 

RUN 

RUN 

MODE 

RUN 

"A" is displayed 

w

hen  

the o

u

tp

u

t is O

N

 or 

u

ntil  

approximately 10 s  
has elapsed. (Key  
operations 

w

ill not 

b

e  

accepted in the stat

u

s.) 

"STAT" 

w

ill 

b

e displayed  

and the slo

w

-motion  

display 

w

ill start. 

The incident le

v

el in  

inter

v

als of 17 µs  

w

ill 

b

e displayed  

for approximately 20 s  
e

v

ery 160 ms  

(

b

et

w

een 0.5 ms 

b

efore  

O

N

 to 1.5 ms after O

N

). 

The o

u

tp

u

t O

N

 time 

w

ill  

b

e displayed. 

E

N

w

ill 

b

e displayed.  

The display 

w

ill ret

u

rn to  

the normal display. 

STAT 

Incident le

v

el Threshold 

Incident le

v

el Threshold 

Incident le

v

el Threshold 

O

u

tp

u

t O

N

 time 

Unit: µs 

E

N

Incident le

v

el Threshold 

Incident le

v

el Threshold 

Set the SET/RU

N

 Mode 

Selector S

w

itch to RU

N

(Factory-set to RU

N

Displaying the Change of the incident le

v

el 

Error  

Display  

Changes of the incident le

v

el for high-speed 

w

orkpiece  

detection can 

b

e displayed. This ena

b

les checking the  

margin le

v

el of light recei

v

ed and the 

w

orkpiece O

N

 time  

in slo

w

 motion. 

Set the SET/RU

N

 Mode 

Selector S

w

itch to RU

N

(Factory-set to RU

N

T

u

rn OFF the o

u

tp

u

t or  

con

v

ey the 

w

orkpieces.  

O

V

ER US 

The follo

w

ing 

w

ill 

b

e displayed  

if the O

N

 time exceeds 1,500 µs.  

 

N

O

N

 DETC 

The follo

w

ing 

w

ill 

b

e displayed  

if the change in the light amo

u

nt is lo

w

✽ 

Press the MODE key. 

Press the MODE Key,   
or 

w

ait for the slo

w

-motion  

display to end. 

 This may also 

b

e displayed 

w

hen detecting  

w

orkpiece 

w

ith a small change in light amo

u

nt  

or a slo

w

 

w

orkpiece of 1,500 µs or longer.  

 

Set the SET/RU

N

 Mode 

Selector S

w

itch to RU

N

(Factory-set to RU

N

Locking the Keys (Easy Key Lock) 

Before shipment, all key operation except for the MODE  
Keys can 

b

e disa

b

led. 

 

Note:

 Do not s

w

itch the lock 

w

hile in SET Mode. Doing so 

w

ill disa

b

le  

changing settings. If the lock is s

w

itched to in SET Mode, ret

u

rn to  

the 

u

nlock state, and then make the setting again. 

Unlocking  

Locked 

Set the Easy Key Lock  

Selector S

w

itch to Locked . 

Locked 

Set the Easy Key Lock  

Selector S

w

itch to Locked . 

Unlocked 

Set the Easy Key Lock  

Selector S

w

itch to Unlocked . 

Basic operating procedures are as given on

 

pages 14 to 18. 

For details, refer to the Instruction Manual provided with the product. 
This section shows functions specific to the E3X-DA

@

F-S. 

Summary of Contents for E3X-DA-S

Page 1: ...the E3X DRT21 S VER 3 use an E3X CN02 Connector without a Cable for the Wire saving Connector Sensor Communications Unit Connector Models for EtherCAT and CompoNet Dimensions page 29 For the most rec...

Page 2: ...connector 3 E3X CN11 Slave connector 1 E3X CN12 Appearance Model Quantity E39 L143 1 Appearance Model Quantity PFP M 1 Types Standard models 1 Ultra long term APC models High speed response models Co...

Page 3: ...igh speed Mode 4 Operate or reset 80 s Operate or reset 80 s NPN output Operate 46 s Reset 48 s PNP output Operate 51 s Reset 53 s High speed Mode Operate or reset 250 s Standard Mode Operate or reset...

Page 4: ...Vibration resistance Destruction 10 to 55 Hz with a 1 5 mm double amplitude for 2 hours each in X Y and Z directions 10 to 150 Hz with a 0 7 mm double amplitude for 80 min each in X Y and Z direction...

Page 5: ...D211R 2M 140 100 60 40 16 M6 E32 D11R 2M 840 600 350 240 100 E32 CC200 2M 1 400 1 000 600 400 180 E32 LD11 2M 860 610 360 250 110 E32 LD11R 2M 840 600 350 240 100 Sensing method Size Sensing directio...

Page 6: ...0 350 240 100 E32 D25 S3 2M 250 170 110 72 30 Type Spot diameter Center distance mm Model Sensing distance mm Tough mode High resolution mode Standard mode High speed mode Super high speed mode Variab...

Page 7: ...800 500 200 Top view 12 E32 T11 2M E39 F1 4 000 2 4 000 2 4 000 2 4 000 2 1 860 6 E32 T11 2M E39 F16 4 000 2 4 000 2 4 000 2 4 000 2 4 000 2 Side view 60 E32 T11 2M E39 F2 2 300 1 640 1 320 860 320 To...

Page 8: ...mode High speed mode Super high speed mode Limited reflective Small size Flat view E32 L24S 2M 0 to 4 Standard E32 L16 N 2M 0 to 15 0 to 12 Glass substrate alignment 70 C E32 A08 2M 10 to 20 Standard...

Page 9: ...tive 100 C E32 D51R 2M 670 480 280 190 80 150 C E32 D51 2M 1 120 800 450 320 144 200 C E32 D81R S 2M 420 300 180 120 54 300 C E32 A08H2 2M 10 to 20 E32 A09H2 2M 20 to 30 center 25 350 C E32 D611 S 2M...

Page 10: ...resolution mode Standard mode High speed mode Super high speed mode Limited reflective Glass presence detection 70 C E32 L16 N 2M 0 to 15 0 to 12 Glass substrate alignment E32 A08 2M 10 to 20 300 C E3...

Page 11: ...200 90 E32 LD11 2M 430 305 180 125 55 E32 LD11R 2M 420 300 170 120 50 Sensing method Size Sensing direction Model Sensing distance mm Tough mode High resolution mode Standard mode High speed mode Supe...

Page 12: ...pot diameter Center distance mm Model Sensing distance mm Tough mode High resolution mode Standard mode High speed mode Super high speed mode Variable spot 0 1 to 0 6 dia 6 to 15 E32 C42 1M E39 F3A Sp...

Page 13: ...660 430 160 Top view 12 E32 T51R 2M E39 F1 4 000 2 3 900 2 900 1 900 760 6 E32 T51R 2M E39 F16 4 000 2 4 000 2 4 000 2 3 600 1 400 Side view 60 E32 T51R 2M E39 F2 700 500 360 250 100 Top view 12 E32...

Page 14: ...Sensing distance mm Tough mode High resolution mode Standard mode High speed mode Super high speed mode Through beam Oil resistant Right angle E32 T11NF 2M 4 000 1 4 000 1 4 000 1 3 100 1 200 Chemica...

Page 15: ...840 560 220 E32 T16JR 2M 1 370 980 750 480 190 30 mm E32 T16WR 2M 2 000 1 700 1 300 850 340 Reflective Array 11 mm E32 D36P1 2M 350 250 150 100 45 Sensing method Tube diameter Feature Model Sensing di...

Page 16: ...38 300 C E32 A09H2 2M 20 to 30 center 25 Wet processes Cleaning Resist developing and etching 60 C E32 L11FP 2M 8 to 20 mm from tip of lens Recommended detection distance 11 mm 19 to 31 mm from center...

Page 17: ...OFF Operate Reset Between brown and black orange leads ch1 ch2 Operation indicator orange Output transistor Load e g relay Incident light No incident light ON OFF ON OFF Operate Reset Between brown an...

Page 18: ...t value Incident level Threshold Setting Thresholds Manually RUN Mode 3 Display Error Action A threshold can be set manually A threshold can also be adjusted manually after teaching to fine tune it Th...

Page 19: ...edure SET You can set the threshold to below the incident light level without a workpiece by the percentage set for the teaching level will be displayed With no workpiece With no workpiece The thresho...

Page 20: ...he UP and DOWN Keys to change the settings UP DOWN Light ON Dark ON 0 Operation mode Used to set the differential response time Single edge Double edge Differential edge differential operation selecte...

Page 21: ...l unit number Normal display Up down reversed display 7 Display orientation Used to reverse the orientation of the display Used to enable or disable the ECO mode Used to display the peak and bottom le...

Page 22: ...elector Switch to RUN Factory setting Press both for 3 s Press both for 3 s Press both for 3 s Press both for 5 s 3 s MODE MODE UP DOWN SET All settings can be returned to the factory defaults or to u...

Page 23: ...larm output indicator will light regardless of the operation of the APC margin display Set the SET RUN Mode Selector Switch to RUN Factory set to RUN Press the MODE Key to display the following for 10...

Page 24: ...nge of the incident level Error Display 2 Changes of the incident level for high speed workpiece detection can be displayed This enables checking the margin level of light received and the workpiece O...

Page 25: ...load or the load line before turning OFF the power supply to the sensor Mutual Interference Protection Function Mutual interference prevention is enabled if Amplifier Units are connected together It...

Page 26: ...M correctly due to a power failure or static electric noise initialize the settings with the keys on the Amplifier Unit ERR EEP will flash on the display when a writing error has occurred Optical Comm...

Page 27: ...Attached Mounting Holes 16 5 9 4 Mounting Bracket E39 L143 SUS304 stainless steel sold separately 16 18 7 4 3 4 3 18 7 4 3 Vinyl insulated round cable Standard length 2 m 2 Hole for optical communica...

Page 28: ...f DIN track DIN track sold separately PFP N Mounting Bracket E39 L143 SUS304 stainless steel sold separately Hole for optical communications 16 18 7 4 3 8 1 4 3 8 1 10 3 16 Wire saving Connector Model...

Page 29: ...4 11 7 11 75 12 15 3 25 29 8 Two 3 2 dia 18 7 Master Connector E3X CN21 7 2 000 50 0 Edge of amplifier E3X CN21 4 dia vinyl insulated round cable with 4 conductors Conductor cross section 0 2 mm2 Ins...

Page 30: ...000 50 0 Edge of amplifier Slave Connector E3X CN12 7 Cable 2 6 dia vinyl insulated round cable with 1 conductors Conductor cross section 0 2 mm2 Insulator diameter 1 1 mm 2 000 50 0 Edge of amplifie...

Page 31: ...y be suitable for the products Outdoor use uses involving potential chemical contamination or electrical interference or conditions or uses not described in this document Nuclear energy control system...

Page 32: ...5302 U S A Tel 1 847 843 7900 Fax 1 847 843 7787 Regional Headquarters OMRON EUROPE B V Sensor Business Unit Carl Benz Str 4 D 71154 Nufringen Germany Tel 49 7032 811 0 Fax 49 7032 811 199 Contact ww...

Reviews: