Digital Fiber Sensor
RUN
SET
Teaching
0. Operation Mode
Light-ON
Dark-ON
Switch to SET mode.
1. Detection Mode
Set separately for each channel.
Set separately for each channel.
2. Timer Function
Note: Refer to 7. Basic Settings for teaching methods.
Zero reset
Switch to RUN mode.
Switch to RUN mode.
Switch to RUN mode.
Switch to RUN mode.
The display will be zeroed,
i.e., the conformity will be
displayed as 0.
RUN
SET
RUN
SET
RUN
SET
Press the MODE key for
3 seconds or more.
RUN
SET
KeyLock
+
+
+
Light level
Threshold
LOC
ON
LOC
OFF
Standard mode
High-resolution mode
High-speed mode
8. Detailed Settings
9. Convenient Functions
T
“Light lerel/Threshold”
⇔
“TECH/Threshold”are displayed in fixed time.
E3X-DA
□□
-S
Instruction Sheet
Thank you for selecting OMRON product.This sheet primarily describes precautions
required in installing and operating the product.
Before operating the product, read the sheet thoroughly to acquire sufficient knowledge
of the product. For your convenience, keep the sheet at your disposal.
Super-high-speed mode
Set separately for each channel.
Setting range: 0P to 99P
If the teaching level is small or large, it is set to
upper or lower of threshold to operate correctly.
Hold down the MODE key and
press the DOWN key
for 3 seconds or more.
Frash twice and the zero
reset function will be cleared.
The light level displayed on the main display can be zeroed. The threshold displayed in
the sub-display is shifted by an amount corresponding to the amount the light level was
changed. Confirm that the MODE key setting is 0RST (zero reset) in advance.
■
Setting Method
■
Clearing Method
Key operations can be disabled to help prevent key operating errors.
■
Setting Method
■
Clearing Method
Flash twice and key input
will be enabled.
Flash twice and key input
will be disabled.
If a key is pressed while key operations are locked,
"LOC ON" will flash twice on the display to indicate
that key operations have been disabled.
User Save
RUN
SET
Save has been completed.
Not save
NO?
YES?
Save
Switch to SET mode.
Press the MODE key and the UP key
at the same time for 5 seconds or more.
SAVE
NO?
GOOD
■
Setting Method
+
The current setting can be saved.
Threshold
GOOD
Threshold
Initial Reset, User Reset
RUN
SET
Initialization has been
completed.
Not initialized
NO?
YES?
Initialized
Switch to SET mode.
Press the UP key and the DOWN key for 5 seconds or more.
+
INIT
NO?
■
Setting Method
Initial reset: Initialize all of settings (except user save) to return to the default states.
User reset: Return to the saved states.
1) When user save is not executed(Initial reset only)
RUN
SET
User reset
USER
INIT
Initial reset
Switch to SET mode.
Press the UP key and the DOWN key for 5 seconds or more.
+
RST
USER
USER
■
Setting Method
2) When user save is executed(Select initial reset or user reset)
GOOD
Threshold
User reset has been
completed.
Not execute
user reset
NO?
YES?
Execute
user reset
Refer to 1)
When user save
is not executed.
NO?
ERR
EEP
10. Error display
If the error occurs, the error messages are blinking as below.
In these case Execute following procedures to restore.
OVER
CUR
EEPROM error
Execute initial reset operation.
The following functions can be set in SET mode. The function displays are the default
settings. All settings except for the operation mode, detection mode, timer function, teaching
level setting and ACT setting are the same for both channels .
*
: The values shown for thresholds, light level, ratio, etc., are examples only. Actual displays may vary.
Overcurrent of control output
Check an output load and keep current in rating.
Check whether the load to be short-circuited.
Power supply
connector
Protector seal
Precautions for Correct Use
Precautions for Safe Use
1)Do not use the Amplifier Unit in environments subject to flammable or explosive gases.
2)Do not use the Amplifier Unit in environments subject to exposure to water, oil, chemicals, etc.
3)Do not attempt to disassemble, repair, or modify the Amplifier Unit in any way.
4)Do not apply voltages or currents that exceed the rated ranges.
5)Do not use the Amplifier Unit in atmospheres or environments that exceedproduct ratings.
6)Wire the Amplifier Unit correctly, e.g., do not reverse the polarity of the power supply.
7)Connect the load correctly.
8)Do not short both ends of the load.
9)Do not use the Amplifier Unit if the case is damaged.
10)When disposing of the Amplifier Unit, treat it as industrial waste.
11)Do not use the sensor in the place exposed to the direct sunlight.
1)Do not use the Amplifier Unit under the following conditions.
①
In the place exposed to the direct sunlight.
②
In the place where humidity is high and condensation may occur.
③
In the place where corrosive gas exists.
④
In the place where vibration or shock is directly transmitted to the product.
2)Wire the Amplifier Unit separately from power supply or high-voltage lines.
If the Amplifier Unit wiring is wired together with or placed in the same duct
as high-power lines, inductive noise may cause operating errors or damage the Amplifier Unit.
3)For extending wires,use a cable 0.3mm min., and 100m max. in length.
When using the cable as a Korea’s S-mark certified product, use the cable of less than 10m
in length.
4)Do not extend the follwing force values applied the cable.Tensile:40 N max.,torque:0.1 Nm
max.,pressure:20 N max.,flexure:3 kg max.
5)The Amplifier Unit is ready to operate 200 ms after the power supply is turned ON. If the
Amplifier Unit and load are connected to power supplies separately, turn ON the power supply
to the Amplifier Unit first.
6)Please turn on the power supply at the same time when you connecting use the amplifier units
with cables.
Mutual interference prevention might not operate normally or mobile console might not be able
to be used when the difference between connected amplifiers at the power supply turning on
time is 30ms or more.
7) Depending on the application environment, time may be required for the light level to
stabilize after the power supply is turned ON.
8)Output pulses may occur when the power is interrupted, so turn OFF the ower to the load or
load line before turning OFF the power to the Sensor.
9)When you use the Amplifier Units with Connectors,
to prevent electric shock or short-circuits, attach
the protector seals provided with E3X-CN-series
Connectors to the sides of power supply
connectors that are not being used.
10)Always turn OFF the power supply before connecting,
separating, or adding Amplifier Units.
11)Do not pull or apply excessive pressure or force
(exceeding 9.8 N
・
m) on the Fiber Unit when it is
mounted to the Amplifier Unit.
12) Mobile console E3X-MC11-SV2 doesn't correspond to the new feature such as tough mode
and ON delay OFF delay timer now. E3X-MC11-S cannot be used.
13)Optical communication are not possible with the E3X-DA-N.
Optical communication are possible with the E3X-DA-S or the E3X-MDA.
14)Always keep the protective cover in place when using the Amplifier Unit.
15)Do not use thinners, benzine, acetone, or kerosene for cleaning the
Amplifier Unit.
Confirming the Package Contents
OVER
flash twice
flash twice
LO
Over error
Low error
■
Teaching Error
After execute teaching, when the following is displayed on sub digital display, the error
has occurred. Deal referring to the following.
The incident light level is too
large.
・
After decrease the light level by the power tuning, execute re-teaching.
・
After adjust the Fiber Unit to decrease the incident light level,
execute
re-teaching.
The incident light level is too small.
・
After setting the detection method at a slower response time,
execute
re-teaching.
・
After adjust the Fiber Unit to increase the incident light level,
execute
re-teaching.
Setting
Display
Switch to RUN mode.
RUN
SET
Threshold
Light level
1)Manual Setting
Adjust the threshold with the
UP key or the DOWN key.
The display set by the display
switch will return in
approximately 5 seconds.
DIN Track
1
2
DIN Track
Hook on the Fiber Unit connector end
1
2
4
3
5. Installing the Amplifier Unit
6. Connecting the Fiber Unit
1. Open the protective cover
2. Press up the lock button.
3. Insert the fiber unit all the way to the back of the
connector insertion opening.
4. Return the lock button to its original position
to secure the fiber unit.
■
Mounting Units
Catch the hook on the Fiber Unit connector end of the
Unit on the DIN Track and then press down on the
other end of the Unit until it locks into place.
Always attach the Fiber Unit connector end first.
If the incorrect end is attached first, the mounting
strength will be reduced.
■
Removing Units
Press the Unit in the direction indicated by "1"
and then lift up on the Fiber Unit connector end
of the Unit in the direction indicated by "2."
■
Joining Amplifier Units (for Units with Connectors)
Up to 16 Units can be joined.
1. Mount the Amplifier Units one at a time onto the
DIN Track.
2. Slide the Amplifier Units together and press the
Amplifier Units together until they click into place.
Secure the Units with an End Plate (PFP-M) if
there is a possibility of the Amplifier Units moving,
e.g., due to vibration.
Remove the Units in the reverse order.
4. Nomenclature
(Unit: mm)
(Pre-wired Models)
3. Dimensions
10
4.5
5.65
18.7
36.7
3.4
9.9
4.3
70
44.3
8.1
32
12.5
12.15
15.1
29.8
32.8
3.9×3=11.7
3.9×3=11.7
Tw
o,2.4 dia.
1. Ratings and Specifications
2. I/O Circuits
12 to
24 VDC
Brown
Orange
Blue
12 to
24 VDC
Brown
Orange
Blue
External
input *
External
input *
■
E3X-DA21-S, E3X-DA7-S,E3X-DA0-S
(
NPN models
)
■
E3X-DA51-S, E3X-DA9-S
(
PNP models
)
Internal circuits
Internal circuits
Load
Load
Load
Load
Black
Black
Pink
Pink
Output for
channel 1
Output for
channel 1
Output for
channel 2
Output for
channel 2
•
Amplifier Unit: 1
•
Instruction Sheet (this sheet): 1
Hold down the MODE key
and press the UP key
for 3 seconds or more.
Hold down the MODE key
and press the UP key
for 3 seconds or more.
Press the MODE key
Switch the UP key or DOWN key
0RST
OFF
③
Operation indicator for channel 2 (orange)
⑥
Channel selector
1
2
UP
S E T
RUN
1
2
DOWN
MODE
⑧
Lock button
①
Operation indicator
for channel 1 (orange)
②
Main display (red)
④
Sub-display (green)
⑦
Operation keys
⑤
SET/RUN switch
SET Select for various settings or teaching.
Mode
Description
RUN Select for operating, threshold value adjusting or various executings.
⑧
Used to connect and disconnect the Fiber Unit.
UP key
Increases the threshold or threshold
ratio.
Depends on the setting.
• Executes teaching.
• Changes the setting forward.
Decreases the threshold or threshold
ratio.
Switches the function to be set on the
display.
DOWN key
MODE key
Key
Function
RUN mode
SET mode
Depends on the setting.
• Executes teaching.
• Changes the setting in reverse.
Execute variously depends on the MODE
key setting.
LON (light-ON)
Selection
Description
DON (dark-ON)
RUN
SET
Switch to RUN mode.
Tuning completed and previous display returns.
Main Display
Press the MODE key for at least 3 seconds.
Power tuning target value
PTUN
During power tuning
Progress bar
PTUN
The output will turn ON when the incident light level is above the threshold.
If DIFF (differential operation) is set for the detection method, the output will turn
ON when an edge is detected.
The output will turn ON when the incident light level is below the threshold.
If DIFF (differential operation) is set for the detection method, the output will turn
OFF when an edge is detected.
Confirm that the MODE key setting is PTUN (power tuning) in advance.
A progress bar will appear on the
sub-display one digit at a time.
(Release the MODE key when the progress
bar appears.)
Display
alternates at a
fixed interval.
Select either light-ON or dark-ON operation.
Set as the operation mode in SET mode. Refer to 8. Detailed Settings.
Power tuning can be used to adjust the incident light level that is currently being received to the power tuning target
value (default: 2,000). Before tuning ON the power, always secure the detection object and Head and be sure that the
incident light level is stable.
■
Setting Method
The power tuning target value can be changed. Refer to 8. Detailed Settings.
7. Basic Settings
1. Setting the Operation Mode
2. Adjusting the Power (as Required)
Setting
Display
Setting
RUN
mode
SET
mode
Display
•
Power tuning Errors
An error has occurred if one of the following displays appears after the progress bar is displayed.
Over Error
The incident light level is too low for the power tuning target value.
The power can be increased up to approximately 5 times the incident
light level without power tuning.
PTUN
OVER
Switch to RUN mode
Bottom Error
The incident light level is too high for the power tuning target value.
The power can be decreased down to approximately 1/20th the incident light
level without power tuning.
PTUN
BOTM
PTUN
OFF
RUN
SET
Hold down the MODE key and press the DOWN key for at least 3 seconds.
Note: Press the DOWN key right after pressing the MODE key.
Flashes twice
Flashes twice
+
■
Clearing Method
Effective set for ATC function
Switch to RUN mode.
Switch to RUN
mode.
Press the MODE key
for at least 3 seconds.
The sub-display will flash.
The threshold value
that was set will flash
twice.
Press the UP or
DOWN key.
Press the UP or
DOWN key.
Press the MODE key
for at least 3 seconds.
Switch to SET
mode.
With a workpiece
Without a workpiece
RUN
SET
Threshold
ratio
Light level
Threshold
ratio
Workpiece
Threshold value
The threshold ratio is adjusted or the threshold is updated by the incident level every about 3 seconds by ATC start.
Confirm that the MODE key setting is ATC in advance.
2
) Teaching
①
2-point teaching
Teaching can be performed twice, once with and once without a workpiece, and the value between
the two measured values is set as the threshold. RUN mode and SET mode – each mode can be set up.
ATC
TECH
ー
2PNT
Adjust the threshold ratio
value with the UP and
DOWN keys .
The threshold value that was set will
flash twice.
Press the MODE key at least 3
seconds.
RUN
SET
RUN
SET
Switch to RUN
mode.
RUN
SET
If DIFF (differential operation) is set for the detection method, the threshold value
will be set to half of the difference between the two measured values.
3. Setting Thresholds
Setting
Display
AUTO
Threshold
value
AUTO
Light level
⑥
Automatic-teaching(It sets up at move work.)
While continuing pushing a key, the middle of the detected maximum and the minimum value can be
set up as a threshold. Confirm that the MODE key setting is AUTO in advance.
Pushing the MODE key
during 3 seconds or more
It is displayed on a sub digital
value as AUTO, and the
sampling of right level is
effective.
Threshold value will flush twice.
This method cannot be used to set the threshold when the detection method has
been set to DIFF (differential operation).
Setting
Display
Switch to RUN mode.
Without a workpiece
Press the UP or DOWN key .
The sub-display will flash.
The threshold value that was
set will flash twice.
RUN
SET
Switch to RUN mode.
RUN
SET
②
Teaching for Through-beam Sensor Heads
It is performed without a workpiece. The threshold will be set to lower with ratio in the teaching
level setting for the light level of no workpiece. Refer to 8. DetailedSetings.
TECH
THRU
Threshold
value
If DIFF (differential operation) is set for the detection method, the threshold value will
be set to the minimum value that can be detected with stability for the light level of the
without worlpiece.
Setting
Display
Remove a workpiece
3 seconds
Switch to RUN mode.
SET
Switch to RUN
mode.
RUN
SET
TECH
RFCT
Threshold
value
③
Teaching for Reflective Sensor Heads
It is performed without a workpiece (i.e., for the background). The threshold will be set to upper
with ratio in the teaching level setting for the light level of no workpiece. Refer to 8. DetailedSetings.
Press the UP or
DOWN key .
Press the UP or DOWN key for
at least 3 seconds.
The sub-display will flash
twice.
The threshold value that was set
will flash twice.
If DIFF (differential operation) is set for the detection method, the threshold value will
be set to the minimum value that can be detected with stability for the light level of the
without worlpiece.
Setting
Display
Switch to SET mode.
RUN
SET
Switch to RUN mode.
RUN
SET
Threshold
value
FULL
④
Setting the Threshold at the Maximum Sensitivity
The threshold can be set at the maximum sensitivity. This is convenient when using the longest
sensing distance.
Press the UP or DOWN key for at
least 3 seconds.
The threshold value that was set
will flash twice.
Execute it by the without workpiece.
The value that is set will depend on the detection method and power tuning settings.
1
2
①
Lit when the output for channel 1 is ON.
②
Displays the incident light level,the function name or the change in the incident light lerel.
③
Lit when the output for channel 2 is ON.
④
Display the threshold, the setting of the function displayed on the main disply or threshold ratio.
⑤
Used to switch the mode.
⑥
Used to select the channel to display or set.
⑦
Used to change the display or set functions.
Tough mode
Differential operation mode
Operation is according to the change
in the incident light level.The output
for channel 2 is always an alarm
output for the absolute light level.
1-ms increments
1 to 20 ms
5-ms increments
20 to 200 ms
100-ms increments
200 to 1000 ms
1000-ms increments
1000 to 5000 ms
Single edge
Either the rising or falling
edge is detected.
Double edge
Both the rising and falling
edge are detected.
250 ms
500 ms
500 ms
1 ms
1 ms
2 ms
10 ms
20 ms
100 ms
200 ms
Single edge
This setting depends on the setting for
the differential edge selection.
Setting range: 1 to 5,000
Double edge
Not
Not ,
Differential
Edge Selection
Differential
Response Time
Timer Time
Timer disabled.
OFF-delay timer
ON-delay timer
One-shot timer
----
OFFD
ON-D
1SHT
ONOF
On-delay OFF-delay timer
ON-delay
Timer
OFF-delay
Timer
3. Teaching Level
Setting
Disable ATC.
ON
OFF
ATC function is effective.
Set separately for each channel.
4. ACT Setting
Not
Maximum power
FULL
Setting range: 100 to 3,900, FULL
The function of the MODE key in RUN mode can be selected.
5. MODE Key
Setting
The information displayed in RUN mode can be selected.
When going to SET mode, this setting will be ignored and
the incident light level and threshold value will be displayed.
6. Display
Switch
Light level
PEAK
Light level
Channel
The incident light level
and the channel.
Light level
Threshold
% light level Threshold
L-PE
D-BT
Detection status
Alternates at
a fixed interval
PEAK
BOTM
Peak level
Bottom level
The current incident
light level and the peak
incident light level.
The incident light level
and threshold value
The incident light level as a
percentage of the threshold value
and the threshold value.
The peak incident level and
bottom incident level of fixed
time(2s).
The incidient light peak level
and no incident light bottom
level.
Analog bar display. The
current detection status is
displayed as an analog bar.
The bar will lengthen from the
right as ON status is reached.
Tunes the power.
2-point teaching.
Automatic-teaching.
PTUN
0RST
Executes a zero reset.
2PNT
AUTO
ATC
Executes.
Normal display.
D123
321D
Reversed display.
7. Display
Orientation
The function of the output for channel 2 can be selected.
9. Output Setting
The output for channel 1 functions according to the
detection mode selection.
This setting is not value if DIFF (differential operation)
is set for the detection method. (The output for channel
2 is always an alarm output for differential operation.)
Output for each channel
2OUT
AREA
Output if level is between the two
thresholds.
SELF
Self-diagnosis output
Output when the incident light level
is not stable, i.e., when the light level of 1CH is ±10% of
the threshold value for 300 ms or longer.
The item that is controlled by the input from an external device
can be selected.
Through-beam, no-workpiece teaching
THRU
RFCT
Reflective, no-workpiece teaching
2PNT
2-point teaching
AUTO
Automatic teaching
10. External
Input Setting *
PTUN
Power tuning
0RST
Zero reset
LOFF
Light OFF (The light will remain OFF as
long as the input is ON.)
ATC
ATC start
The teaching cannot be executed even.
8. Eco Mode Setting
Effective Pulse Widths
0.1 to 2 s
Executing: 0.1 to 2 s
Clearing: 3 s or longer
Effective ON pulse
width: 0.1 s min.
Selection
Pulse width
,
,
Effective pulse
width: 3 s
OFF
ECO1
Standard brightness.
Dims the display.
Turns off the display.
ECO2
D
C
D
C
When DIFF is selected for detection method ,ACT
function is diasabled.
B
A
LON
DON
A
B
STND
HRES
DIFF
SHS
HS
TG
*1: Both the E3X-CN21 Master Connector (4-conductor) and the E3X-CN22 Slave Connector (2-conductor) can be used.
*2: Communications and mutual interference prevention does not function if super-high-speed mode is selected
for the detection mode.
*3: Mutual interference prevention can be used for only up to 6 Units if power tuning is enabled.
*4: Sensing distance is about 1/2 and light level is about 1/3 when the eco-mode is effective.
Model NPN
PNP
Control output quantity
External input quantity
Connection method
Light source
(emission wavelength)
Power supply voltage
Power consumption
Control output
External input
Protection circuits
Response Super-high-
time speed mode
High-speed
mode
Standard mode
High-resolution
mode
Tough mode
Sensitivity setting
Functions Power tuning
Differential
detection
Timer
Auto power control
ATC
Zero reset
Setting reset
Mutual interference
prevention
Eco mode
Output setting
External input
settings
−
2
1
Load power supply voltage: 26.4 VDC max.; NPN/PNP open collector;
load current: 50 mA max.; residual voltage: 2 V max. off-stage current: 10µA max.
Operating:Groups of 1 to 2 Amplifiers: −25°C to 55°C
Groups of 3 to 10 Amplifiers: −25°C to 50°C
Groups of 11 to 16 Amplifiers: −25°C to 45°C
Storage: −30°C to 70°C (with no icing or condensation)
Operating and storage: 35% to 85% (with no condensation)
20 M
Ω
min.
(at 500 VDC)
1,000 VAC at 50/60 Hz for 1 minute
Destruction: 10 to 55 Hz with a 1.5-mm double amplitude
for 2 hours each in X, Y and Z directions
IEC 60529 IP50 (with Protective Cover attached)
Approx. 100 g Approx. 55 g Approx. 55 g
Polybutylene terephthalate (PBT)
Polycarbonate (PC)
Operate or reset: 80 µs
Operation indicator for channel 1 (orange), Operation indicator for channel 2 (orange)
E3X- DA21-S
E3X- DA7-S
E3X- DA51-S
E3X- DA9-S
Pre-wired
2
−
Wire-saving connector
No-voltage input
Normal: 960 mW max.
(
current consumption: 40 mA max. at power supply voltage of 24 VDC,
80 mA max. at power supply voltage of 12 VDC
)
ECO1
:
720 mW max.
(
current consumption: 30 mA max. at power supply voltage of 24 VDC,
60 mA max. at power supply voltage of 12 VDC
)
ECO2
:
600 mW max.
(
current consumption: 25 mA max. at power supply voltage of 24 VDC,
50 mA max. at power supply voltage of 12 VDC
)
Red LED(625nm)
12 to 24 VDC ±10%, ripple (p-p) 10% max.
Power supply reverse polarity protection, Output short-circuit protection and Output
reverse polarity protection.
Incandescent lamp: 10,000 lux max., Sunlight: 20,000 lux max.
Initial reset or user reset
Possible for up to 10 Units
Light level+Threahold, Light level ratio+Threshold,
Peak light level+Bottom light level,
Incident peak light level+No incident bottom light level, Analog bar display,
Light level+Peak light level, Light level+Channel number
7-segment displays (Main display: Red, Sub-display: Green),
display direction can be reversed.
Off, Eco1 or Eco2
Output for each channel, Area output or Self-diagnosis output
Various teachings, automatic teaching, power tuning, zero reset,
light emission OFF or ATC start
Threshold updates at intervals of about 3 s
Negative values can be displayed (Threshold value is shifted, too)
No effect, OFF delay, ON delay, one-shot or ON delay OFF delay
Timer time: 1ms to 5s (variable)
Teaching (2-point teaching, teaching for though-beam sensor heads,
teaching for reflective sensor heads,setting the threshold at the maximum sensitivity,
positioning teaching or automatic-teaching) or munual adjustment
Light emission power and reception gain, digital control method
Switchable between single edge and double edge detection mode
Single edge: 250µs, 500µs, 1ms, 10ms or 100ms
Double edge: 500µs, 1ms, 2ms, 20ms or 200ms
Light level
Light level
*3
*1
*2
Light level
* Only E3X-DA21-S and E3X-DA51-S
If SHS is set for the detection method, the power tuning target value will be not have effect
and the power will be set to the minimum value.
The light level might change when the detection method is changed.
In that case, execute the power tuning again after changing the detection method.
Without the workpiece
ATC-Start is performed at the time of a
power supply injection.
ON
OFF
Disable counter.
The processing executed when the power supply is turned
on is selected.
Setting at power
supply ON
PTAT
Power tuning and ATC-Start is performed
at the time of a power supply injection.
The display turns on the key operation when the Eco-mode is effective.
It returns to the Eco-mode if there is no key operation for ten seconds.
Not
Maximum power
FULL
Setting range: 100 to 3,900, FULL
This method cannot be used to set the threshold when the detection method has been set to
DIFF (differential operation).
⑤
Positioning-teaching
It executes it puts on the place where it wants to position workpiece.
Setting
RUN
mode
Switch to RUN
mode.
Press the MODE key
for at least 3 seconds.
Press the MODE key
for at least 3 seconds.
Workpiece
RUN
SET
Workpiece
Refer to
①
2-point teaching for SET mode and display.
Operate or reset: 250 µs
Operate or reset: 1 ms
Operate or reset: 16ms
Operate or reset: 4 ms
Indicator
Digital switch
Digital display
Ambient illumination
(Receiver side)
Ambient temperature
Ambient humidity
Insulation resistance
Dielectric strength
Vibration resistance
Shock resistance
Degree of protection
Weight (packed state)
Materials Case
Cover
High-speed control method for emission current
*4
RUN
OMRON Corporation
Suitability for Use
EUROPE
OMRON EUROPE B.V. Sensor Business Unit
Carl-Benz Str.4, D-71154 Nufringen Germany
Phone:49-7032-811-0 Fax: 49-7032-811-199
NORTH AMERICA
OMRON ELECTRONICS LLC
One Commerce Drive Schaumburg,IL 60173-5302 U.S.A.
Phone:1-847-843-7900 Fax : 1-847-843-7787
ASIA-PACIFIC
OMRON ASIA PACIFIC PTE. LTD.
No. 438A Alexandra Road #05-05-08(Lobby 2),
Alexandra Technopark, Singapore 119967
Phone : 65-6835-3011 Fax :65-6835-2711
o
THE PRODUCTS CONTAINED IN THIS SHEET ARE NOT SAFETY RATED.
THEY ARE NOT DESIGNED OR RATED FOR ENSURING SAFETY OF
PERSONS, AND SHOULD NOT BE RELIED UPON AS A SAFETY
COMPONENT OR PROTECTIVE DEVICE FOR SUCH PURPOSES.
Please refer to separate catalogs for OMRON's safety rated products.
OMRON shall not be responsible for conformity with any standards, codes, or
regulations that apply to the combination of the products in the customer's
application or use of the product.
Take all necessary steps to determine the suitability of the product for the
systems, machines, and equipment with which it will be used.
Know and observe all prohibitions of use applicable to this product.
NEVER USE THE PRODUCTS FOR AN APPLICATION INVOLVING
SERIOUS RISK TO LIFE OR PROPERTY WITHOUT ENSURING THAT THE
SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS,
AND THAT THE OMRON PRODUCT IS PROPERLY RATED AND
INSTALLED FOR THE INTENDED USE WITHIN THE OVERALL
EQUIPMENT OR SYSTEM.
See also Product catalog for Warranty and Limitation of Liability.
CHINA
OMRON(CHINA) CO., LTD.
Room 2211, Bank of China Tower,
200 Yin Cheng Zhong Road,
PuDong New Area, Shanghai, 200120, China
Phone : 86-21-5037-2222 Fax :86-21-5037-2200
OCT, 2009
ー
E3X- DA0-S
2
−
−
Connector for communication unit
The sub-display will flash twice and power tuning will be cleared.
*E3X-DA0-S: Refer to E3X-CRT Operation Manual (E412-E1-01)or E3X-ECT Operation Manual(E413E1-01).
−
Destruction: 10 to 150 Hz with a
0.7
-mm
double amplitude,50m/s² max.acceleration
for 80min each in X, Y and Z directions
Destruction: 500 m/s²
3 times each in X, Y and Z directions
Destruction: 200 m/s²
2 1 6 6 9 3 6 - 3 A
LOC
ON
Precaution on Safety
●
Meanings of Signal Words
●
Alert statements in this Manual
CAUTION
NOTICE:
This is a class A product. In a domestic environment this product may cause
radio interference in which case the user may be required to adequate measures.
Indicates a potentially hazardous situation which, if not avoided,
May result in minor or moderate injury or in property damage.
Do not connect sensor to AC power supply.
Risk of explosion.
Do not use it exceeding the rated voltage.
There is a possibility of failure and fire.
CAUTION
Write results to EEPROM.
ON
OFF
Do not write results to EEPROM.
Whether external input execution results are written
to EEPROM can be selected. Disable this function
if the external input is turned ON frequently.
(The write life is approximately 100000 writes.)
11. External Input
Memory *
* The external input cannot be used though it is displayed
even by the wire-saving connector
Standard models
Manufacturer:
Omron Corporation,
Shiokoji Horikawa, Shimogyo-ku,
Kyoto 600-8530 JAPAN
Shanghai Factory
No.789 Jinji Road,
Jinqiao Export Processing District,
Pudong New Area,Shanghai,201206 CHINA
TRACEABILITY INFORMATION:
Representative in EU:
Omron Europe B.V.
Wegalaan 67-69
2132 JD Hoofddorp,
The Netherlands