Do not use the product in atmospheres or environments that 

exceed product ratings.

Fiber Amplifier Unit

 Designing

Operation after Turning Power ON

The Sensor is ready to detect within 200 ms after the power 

supply is turned ON. If the Sensor and load are connected to 

separate power supplies, be sure to turn ON the Sensor first.

Time may be required for the degree of match to stabilize after 

the power supply is turned ON.

Operation When Turning Power OFF

Output pulses may occur when the power is turned OFF. Turn 

OFF the power supply to the load and the load line before 

turning OFF the power supply to the Sensor.

 Mounting

Connecting and Disconnecting Connectors

Mounting Connectors

1. Insert the Master or Slave Connector into the Amplifier Unit 

until it clicks into place.

2. Attach the protector seals (provided as accessories) to the 

sides of master and slave connectors that are not 

connected.

Note: Attach the seals to the sides with grooves.

Removing Connectors

1. Slide the slave Amplifier Unit(s) for which the Connector is 

to be removed away from the rest of the group.

2. After the Amplifier Unit(s) has been separated, press down 

on the lever on the Connector and remove it. (Do not 

attempt to remove Connectors without separating them 

from other Amplifier Units first.)

Adding and Removing Fiber Amplifier Units

Adding Fiber Amplifier Units

1. Mount the Amplifier Units one at a time onto the DIN track.

2. Slide the Amplifier Units together, line up the clips, and 

press the Amplifier Units together until they click into place.

Removing Fiber Amplifier Units

Slide Amplifier Units away from each other, and remove from 
the DIN track one at a time. (Do not attempt to remove 

Amplifier Units from the DIN track without separating them 
first.)

Mounting the End Plate (PFP-M)

An End Plate should be used if there is a possibility of the 
Amplifier Unit moving, e.g., due to vibration.

Precautions for Correct Use

Insert

Seal

Remo

v

e

Le

v

er

Press do

w

n

Note 1. The specifications for ambient temperature will vary according to the 

number of Amplifier Unit used together. For details, refer to

 Ratings 

and Specifications

 on 

➜ 

page 3.

2. Always turn OFF the power supply before joining or separating 

Amplifier Units.

Click

into place

End Plate

Downloaded from

Arrow.com.

Downloaded from

Arrow.com.

Downloaded from

Arrow.com.

Downloaded from

Arrow.com.

Downloaded from

Arrow.com.

Downloaded from

Arrow.com.

Downloaded from

Arrow.com.

Downloaded from

Arrow.com.

Downloaded from

Arrow.com.

Downloaded from

Arrow.com.

Downloaded from

Arrow.com.

Summary of Contents for E3X-DAC-S Series

Page 1: ...ee parameters RGB to enable stable detection even when the workpiece moves Not Affected by Move ment Intensity Detection Previous Type Color Detection Color Sensing Type Easy and Reliable Featuring a...

Page 2: ...X DAC41 S 2M Advanced models with simultaneous 2 color determination Standard models Simultaneous 2 color determination AND OR output Remote setting E3X DAC21 S 2M E3X DAC51 S 2M Advanced models with...

Page 3: ...for same color as registered color or ON for mismatch ON for different color from registered color Timer function Timer type OFF delay ON delay or one short Timer time 1 ms to 5 s variable Control out...

Page 4: ...ansistor NPN ON Shorted to 0 V sourcing current 1 mA max OFF Open or shorted to Vcc ON 1 5 V max sourcing current 1 mA max OFF Vcc 1 5 V to Vcc leakage current 0 1 mA max PNP ON Shorted to Vcc sinking...

Page 5: ...19 15 13 4 5 4 1 3 2 4 1 5 E32 D21 E32 D22B 8 8 6 7 5 8 2 1 1 8 1 3 1 1 0 7 E32 D25XB 14 10 9 3 3 2 1 1 7 1 1 Fluorine coating E32 D11U 42 32 26 11 8 5 6 5 3 5 Special beam models Long dis tance high...

Page 6: ...ating E32 T11U 190 140 120 60 40 28 24 20 Special beam models Long dis tance high power E32 T17L 4300 3200 2800 1400 900 600 500 460 E32 TC200 E39 F1 1100 850 700 360 220 160 140 120 E32 T11R E39 F1 1...

Page 7: ...00 E32 T61 S E39 F2 120 95 80 42 26 19 16 14 E32 T84S S 360 280 240 120 75 55 46 40 Chemical resistant E32 T11F 550 420 360 180 110 80 70 60 E32 T12F 850 650 550 280 180 120 100 95 E32 T14F 100 80 70...

Page 8: ...Red purple Black White Red Yellow red Yellow Yellow green Green Blue green Blue Blue purple Purple Red purple Black Number of colors differentiated combinations 0 20 40 60 80 100 120 140 0 Sensing di...

Page 9: ...24 VDC Display For the E3X DAC B S Match Mismatch ON OFF ON OFF Operate Reset Output transistor Between brown and black leads Operation indicator orange Load e g relay Between blue and black leads Ma...

Page 10: ...ding on application conditions such as the ambient temperature and the power supply voltage Use caution when operating or performing maintenance on the Sensor Fiber Amplifier Units Standard Models E3X...

Page 11: ...on the Connector and remove it Do not attempt to remove Connectors without separating them from other Amplifier Units first Adding and Removing Fiber Amplifier Units Adding Fiber Amplifier Units 1 Mo...

Page 12: ...plifier Units can be slid together and used in groups Do not however slide the Amplifier Units or attempt to remove any of the Amplifier Units during operation Others Protective Cover Always keep the...

Page 13: ...N End Plate sold separately PFP M Multiple connection diagram Two 2 4 dia DIN track mounting Fiber Attachment mounted E39 F9 Fiber Attachment mounted E39 F9 Pre wired Amplifier Units E3X DAC11 S E3X...

Page 14: ...rack mounting 12 95 A dia 12 95 A dia Fiber Attachment mounted E39 F9 Fiber Attachment mounted E39 F9 4 3 141 1 141 1 8 1 4 3 141 1 141 1 8 1 Amplifier Units with Connectors E3X DAC6 S E3X DAC8 S Cabl...

Page 15: ...uctor 1 conductor Standard length 2 m Conductor cross section 0 2 mm2 AWG24 Insulator diameter 1 1 mm Edge of amplifier Downloaded from Arrow com Downloaded from Arrow com Downloaded from Arrow com Do...

Page 16: ...y standards codes or regulations which apply to the combination of the Product in the Buyer s application or use of the Product At Buyer s request Omron will provide applicable third party certificati...

Page 17: ...odes or regulations which apply to the combination of the Product in the Buyer s application or use of the Product At Buyer s request Omron will provide applicable third party certification documents...

Reviews: