Explicit Message Communications
●
Write Differentiation Response Speed Settings
It writes the differentiation response time settings of the sensor with the unit No.
specified with the Instance ID.
●
Write Timer Function Settings
It writes the timer function settings of the sensor with the unit No. specified with the
Instance ID.
●
Write Timer Time Settings/Write ON-Delay timer time Settings/Write
OFF-Delay timer time Settings
It writes the timer time settings of the sensor with the unit No. specified with the
Instance ID.
Its write data is expressed in hexadecimal and its length is two bytes; the data range is
between 0000hex (0) and 1388hex (5000).
When the timer function setting is OFF, [Write Timer Time Settings] command fails if
the command is sent.
●
Write Display Switching
It writes the display switching settings of the sensor with the unit No. specified with the
Instance ID.
Bit
Description
Data
00
Differentiation
response time
1: Differentiation response speed setting 1
2: Differentiation response speed setting 2
3: Differentiation response speed setting 3
4: Differentiation response speed setting 4
5: Differentiation response speed setting 5
01
02
03
04 to 15
No data
Always 0
Bit
Description
Data
00
Timer function
0: Timer function disabled
1: OFF-delay timer
2: ON-delay timer
3: One-shot timer
4:ON-delay and OFF-delay timer
01
02 to 15
No data
Always 0
Bit
Description
Data
00
Display switching
setting
0: Detection level and detection level (MDA)
1: Detection level and threshold
2: Detection level ratio and threshold
3: Peak on detected and bottom on undetected
4: Detection level at peak and detection level at bottom (time
update)
(E3X, E3C are bottom on detected and peak on undetected)
5. Analog bar
6: Detection level and peak digital values
7: Detection level and channel number
8: Count value (RM, LDARM)
01
02
03
04 to 15
No data
Always 0