Incident light level setting: The larger incident level of the Step 1 and 2 values is
adjusted to the power tuning level.
Threshold setting: Set to the middle between the Step 1 and 2 incident light levels.
©
OMRON Corporation 2011 All Rights Reserved.
Smart Fiber Sensor
E3X-HD
PRECAUTIONS ON SAFETY
Meanings of Signal Words
Warning Indications
PRECAUTIONS FOR SAFE USE
PRECAUTIONS FOR CORRECT USE
Checking the Package Content
INSTRUCTION SHEET
PRECAUTIONS
Indicates a potentially hazardous situation which, if not avoided,
may result in minor or moderate injury or in property damage.
• Amplifier Unit: 1 • Instruction Sheet (this sheet): 1 (Japanese, English and Chinese)
Do not use the product with voltage in excess of the rated voltage.
Excess voltage may result in malfunction or fire.
Never use the product with an AC power supply. Otherwise,
explosion may result.
■
Mounting on DIN Track
Detect for Workpiece Presence/Absence
Detect for Workpiece Presence/Absence
Let the hook on the Amplifier Unit's Fiber Unit
connection side catch the track and push the
unit until it clicks.
■
Removing from DIN Track
Push the unit in the direction 1.
2-point Tuning
Maximum Sensitivity Tuning
■
Mounting Amplifier Units in Group
(Connector Type Models)
■
Use Fiber Cutter
Insert a Fiber Unit into a fiber cutter hole.
Press down the blade at a single
stroke to cut the Fiber Unit.
Fiber Cutter E39-F4
(Provided with
the Fiber Unit)
Thin-diameter Fiber
Attachment: E39-F9
Thin-diameter
Fiber Unit Hole x 2
Protective Cover
Fiber Unit
Standard Fiber Unit
Hole (dia. 2.2 mm) x 3
■
Mount Fiber Unit
Open the protective cover.
Raise the lock lever.
Insert the Fiber Unit in the fiber
unit hole to the bottom.
Return the lock lever to the original
position and fix the Fiber Unit.
Press button with a workpiece in the detection area.
Press button again without a workpiece in the detection area.
Through-beam: Workpiece is present
Reflective: Workpiece is absent
Press button.
1.
Settings
2
Installation
1
DIN Track
Tighten the screw while pressing the End Plate.
Fiber Unit Connection Side Hook
1
2
Mount the Amplifier Units one at a time onto the
DIN track and push them until they click.
2
1
3
Single Core
Multi Core
1pnt
2pnt
1.
1.
1.
1.
1.
2.
3.
4.
2.
3.
Slide the Amplifier Units in the direction 2.
2.
1.
2.
Workpiece
[L/D Indicator]
Displays
Light ON/Dark O setting.
[OUT Indicator]
Turns ON when Output is
ON.
Green Digital Display
Red Digital Display
[DPC Indicator]
[ST Indicator]
Turns ON when Smart Tuning is in progress.
Threshold Level
Incident Light
Level
Minute Threshold
Adjustment
The green digital value changes.
[UP/DOWN
]
Button
Mode Change
Switches between SET
mode and RUN mode by
a long press (3 seconds
or longer) of the key.
[
MODE
]
Button
Output Switch
[
L/D
]
Button
A single press switches between
Light ON/Dark ON. [L/D] Indicator
changes.
A single press each for setting
with/without a workpiece.
[ST Indicator] turns ON.
Sensitivity Setting
[ ]
Button
Workpiece
Workpiece
Protective Label
Power Supply Connecting Terminal
Setting is Completed
Setting is Completed
When mounting a coaxial reflective
Fiber Unit, insert the single-core
Fiber Unit to the upper hole (Emitter
side) and the multi-core Fiber Unit to
the lower hole (Receiver side).
1-3
Mounting Fiber Unit
2-1
Setting and Display Overview
2-2
Switching Control Output
Smart Tuning [Easy Sensitivity Setting]
2-3
1-1
Dimensions
1-2
Mounting the Amplifier Unit
L/D
1.
Hold button for 3 seconds or longer with/without workpiece as shown below.
Release the button when [ ] is displayed.
The red digital display changes .
Incident light level setting: The incident level in Step 1 is adjusted to "0".
Threshold setting: The value is set to approx. 7% of the incident light level of 1.
If the incident light level of 1 is smaller during long distance
detection, the minimum value by which an output is correctly
turned ON will be set.
2
4
Lock Lever
Lock
Release
Lift it up in the direction 2.
2.
Hold for 3 seconds or longer
Setting Reset
Key Lock
Zero Reset
Step 1 and Step 2 can be reversed.
Turns ON when Dynamic Power Control is
effective.
5.1
9
71.8
20.5
33.4
37.9
20.5
37
12.7
13
4.5
5.7
21.7
5.2
4.2
27.1
170°
(Max.)
146.9 (Max. with the protective cover open)
104.7
(Max. with the protective cover open)
<Wire-saving Connector Model>
Unit: mm
<Pre-wired Model>
With an thin-diameter fiber
attachment (E39-F9)
Blue: 0 V
Brown: 12 to 24 VDC
Black: Output
10
Use E3X-CN11 (Master connector) for the master
Amplifier Unit and E3X-CN12 (Slave connector) for
the slave Amplifier Units.
Insert a standard Fiber Unit up to the
position in which it is cut; and
a thin-diameter Fiber Unit to the
bottom of the hole.
Refer to " Convenient
Setting Features".
Dimensions in parentheses () indicates the ones with related components.
Refer to "1-1. Dimensions" or check the side of
the unit for wire color and role indications.
Use End Plates (PFP-M: separately sold) at the both
ends of the grouped Amplifier Units to prevent them
from separating due to vibration or other cause.
4.
Tighten the screw on the End Plates using a driver.
3
4
Up to 16 Amplifier Units can be mounted in a group.
2
1
Power Tuning
When Light
Level is
Saturated
Reflective: Set to "Light ON" to turn the
output ON with a workpiece in the detection area.
[L/D Indicator] turns ON.
Through-beam: Set to "Dark ON" to turn the
output ON with a workpiece in the detection area.
[L/D Indicator] turns
ON.
Series
+ : Press both
: Press both in sequence
Under environments such as vibration, use an end plate
even with a single amplifier unit.
Thank you for selecting an OMRON product. This sheet
primarily describes precautions
required in installing and operating the product.
• A specialist who has the knowledge of electricity must treat
the product.
• Please read this manual carefully, and use it correctly after
thoroughly understanding the product.
• Please keep this manual properly for future reference
whenever it is necessary.
CAUTION
The following precautions must be observed to ensure safe operation of the Sensor.
• Do not use the Sensor in environments subject to flammable or explosive gases.
• Do not use the Sensor in environments subject to exposure to water, oil, chemicals, etc.
• Do not install the Sensor in environments subject to intense electric field or ferromagnetic field.
• Do not attempt to disassemble, repair, or modify the Sensor Unit in any way.
• Do not apply voltages or currents that exceed the rated ranges.
• Do not use the Sensor in any atmosphere or environment that exceeds the ratings.
• Do not miswire such as the polarity of the power supply.
• Connect the load correctly.
• Do not short both ends of the load.
• Do not use the Sensor if the case is damaged.
• When disposing of the Sensor,treat it as industrial waste.
• Burn injury may occur. The Sensor surface temperature rises depending on application conditions, such as the
ambient temperature and the power supply voltage. Use caution when operating or cleaning the Sensor.
• High-Voltage lines and power lines must be wired separately from this product. Wiring them together or placing
them in the same duct may cause induction, resulting in malfunction or damage.
• When setting the Sensor, be sure to check safety such as by stopping the equipment.
2-2.4 dia.
• Do not install the Sensor in the following locations.
(1) Locations subject to direct sunlight
(2) Locations subject to condensation due to high humidity
(3) Locations subject to corrosive gas
(4) Locations subject to vibration or mechanical shocks exceeding the rated values
• Use an extension cable with a minimum thickness of 0.3 mm2 and less than 100 m long.
• Do not apply the forces on the cord exceeding the following limits:
Pull: 40N; torque: 0.1N·m; pressure: 20N; bending: 3 kg
• The Sensor is ready to operate 200 ms after the power supply is turned ON. If the Sensor and load are
connected to power supplies separately, turn ON the power supply to the Sensor first.
• When using a connector type product, place a protective label (provided with the E3X-CN series
connectors) on the power supply connecting terminals that are not used, to prevent electric shock or short
circuit.
• Output pulses may occur when the power supply is turned OFF. Turn OFF the power supply to the load
or load line first.
• Excessive incident light cannot be sufficiently handled by the mutual interference prevention function
and may cause malfunction. To prevent this, set a higher threshold level.
• Make sure that the power supply is turned OFF before connecting, separating or adding Amplifier Units.
• Do not pull or apply excessive pressure or force (exceeding 9.8N) on the Fiber Unit when it is mounted
on the Amplifier Unit.
• The E3X-MC11-SV2 and E3X-MC11-S Mobile Consoles cannot be used.
• Mutual interference prevention does not function among the E3X-DA-N/SD/NA amplifiers. It functions
among E3X-DA-S/MDA models.
• The E3X-DRT21-S, E3X-CRT and E3X-ECT Communication Units cannot be used.
• Always keep the protective cover in place when using the Amplifier Unit.
• Dor not use thinner, benzine, acetone, and lamp oil for cleaning.
L/D
MODE
UP/DOWN
UP
MODE
→
Incident light level setting: Adjust the max. incident light level on Step 1 as the power tuning level.
Threshold setting: Set to the middle between max. and min. incident light levels on Step 1.
Incident light level setting: The Step 2 incident level is adjusted to half the power tuning level.
Incident light level setting: The Step 2 incident light level is adjusted to the
power tuning level.
Threshold setting: Set to the value obtained by [Incident Level at Step 2 x
Percentage Tuning Level + Incident Level at Step 2].
Adjust for Moving Workpiece without Stopping Line
Determine Workpiece Position
Detect Transparent or Small Workpiece
(Set Threshold by incident light level percentage)
Full Auto Tuning
Position Tuning
Percentage Tuning
Place the workpiece at the desired position and hold button.
Smart Tuning Error
Press button to adjust the threshold level.
per
1.
2.
1.
2.
1.
Press button without a workpiece in the area.
Turn ON Percentage Tuning in SET mode.
Press button without a workpiece in the area.
UP/DOWN
Setting is Completed
Setting is Completed
Error / Display / Cause
Remedy
Error Origin Tuning Type
2-point Tuning
Full Auto Tuning
Positioning Tuning
All
Tuning other than
Maximum Sensitivity
Tuning
The light level difference
between Points 1 and 2 are
extremely small.
Incident light level is too
high.
Incident light level is too low.
Near Error
Over Error
Low Error
2-4
The red digital display changes .
Hold for 3 seconds or longer
The threshold level becomes higher.
The threshold level becomes lower.
Refer to " Detailed Settings".
•
Change the detection function mode to a slower
response time mode.
•
Narrow the emitter and receiver distance (Through-beam)
•
Mount the sensor closer to the workpiece (Reflective)
•
Enhance the power tuning level.
•
Use a thin-diameter fiber.
•
Widen the emitter and receiver distance (Through-beam)
•
Distance the sensor from the workpiece (Reflective)
•
Decrease the power tuning level.
•
Narrow the emitter and receiver distance (Through-beam)
•
Locate the sensor closer to the workpiece (Reflective)
Hold the key for high-speed level adjustment.
1pnt
No Smart Tuning other than Power Tuning can be used if Percentage Tuning is set.
Minute Adjustment of Threshold Level
Threshold setting: Set to the same value as the Step 2 incident level.
Refer to " Detailed Settings" to change the powr tuning level.
err
err
err
Setting is Completed
Workpiece
Hold the button without the presence of a workpiece, and pass the workpiece
through while [ ] -> [ ] -> [ ] is displayed in red digital.
(Keep holding the button while the workpiece passes through, and hold 7
seconds or longer until [ ] is displayed in red digital. After the workpiece passes
through, release your finger from the button.)
1.
Hold for 7 seconds or longer
The adjustment range of smart tuning is approx. 20 to 1/100 times. When selecting Giga Mode as
detection function, the range will be approx. 2 to 1/100 times due to the large initial value.
<M8 Connector Model>
1
2
3
4
12.7
11.2
* 2 1 9 2 1 8 5 - 3
*