background image

Photoelectric Sensors

2-Channel Fiber Sensors

E3X-MDA

• The thinnest profile in the industry, with 

only 5 mm per channel.

• AND/OR control output.
• Flexible control from the Mobile Con-

sole.

• The industry's first power tuning func-

tion in a digital amplifier

• Stable long term performance 

due to Omrons's APC function.

• Two large easy to read displays

The remarkable new 2-channel amplifiers.
The Ultimate space saver!! Only 5mm for one 
channel

Features

Bringing a new dimension to sensing…

…the 2-channel amplifier has arrived.

Summary of Contents for E3X-MDA11

Page 1: ...l from the Mobile Con sole The industry s first power tuning func tion in a digital amplifier Stable long term performance due to Omrons s APC function Two large easy to read displays The remarkable n...

Page 2: ...MDA Having problems gang mounting Fiber Sensor Amplifier Units in tight spaces 50 mm 100 mm Half the Space Incident level Operation indicator Channel 1 display Channel 2 display Incident level Operati...

Page 3: ...mm Remarkable space saving of approx 50 Power saving of approx 40 Savings per channel compared with existing products Detection and front back discrimination of parts Detection of bends in electronic...

Page 4: ...ir cuit is ON or OFF Time OMRON provides the industry s most stable long term detection by using new 4 element LEDs and an APC Auto Power Control circuit Time Without APC circuit Without APC circuit 3...

Page 5: ...output 2 channel models AND OR output E3X MDA11 E3X MDA41 Item Appearance Functions Model NPN output PNP output 2 channel models AND OR output E3X MDA6 E3X MDA8 Item Appearance Cable length No of con...

Page 6: ...from OFF delay ON delay or one shot timer 1 ms to 5 s 1 to 20 ms set in 1 ms increments 20 to 200 ms set in 10 ms increments 200 ms to 1 s set in 100 ms increments and 1 to 5 s set in 1 s increments A...

Page 7: ...nd Z directions Shock resistance destruction 500 m s2 for 3 times each in X Y and Z directions Enclosure rating IEC 60529 IP50 with Protective Cover attached Connection method Prewired cable Standard...

Page 8: ...tion indicator orange ON OFF Output transistor ON OFF Load relay Operate Release Between brown and black CH1 CH2 ON OFF ON OFF L ON D ON T T Incident light No incident light L ON D ON T T Incident lig...

Page 9: ...AND ON delay AND T T T One shot UP DOWN MODE Lock Button Locks the fiber Operation Keys Function setting operations Channel Selector Mode Selector Use to select SET or RUN mode ON when output is ON O...

Page 10: ...ximum sensitivity This method is ideal when using a Through beam Fiber Unit to detect workpieces so that detection is not influenced to any great degree by dust and other environmental factors Display...

Page 11: ...piece and the value between the two measured value can be set as the threshold UP DOWN RUN will be displayed With no workpiece The previous display will return when the setting has been completed The...

Page 12: ...rements of 100 Maximum power M Display orientation orientation To reverse the orientation of the display Up down reversed display Normal display 1 Light levels for channels 1 and 2 The incident light...

Page 13: ...N delay timer is selected the one shot timer is automati cally set i e the timer function cannot be selected Output for each channel Output when the output is ON for both channels 1 and 2 Output when...

Page 14: ...in To return to original value for incident light level Set the Mode Selector to RUN Factory setting 3 s Press together see note MODE MODE UP UP RUN OFF will flash twice and key operations will be ena...

Page 15: ...it Do not attempt to remove Connectors without separating them from other Amplifier Units first Joining and Removing Amplifier Units Joining Amplifier Units 1 Mount the Amplifier Units one at a time...

Page 16: ...to light from other sensors If this occurs decrease the sensitivity i e decrease the power or increase the threshold to perform stable detection EEPROM Writing Error If the data is not written to the...

Page 17: ...6 28 1 4 5 10 7 5 65 4 5 16 Two M3 E3X MDA11 E3X MDA41 Main display Sub display Vinyl insulated round cable Standard length 2 m Cable Specifications A 4 dia 2 conductor conductor cross sectional area...

Page 18: ...Diameters E3X CN11 3 conductors E3X CN21 4 conductors E3X CN22 2 conductors 4 0 mm dia E3X CN12 1 conductor 2 6 mm dia Connector Dia A 2 Hole for optical communications Mounting Holes First operation...

Page 19: ...ble conductor cross sectional area 0 2 mm2 insulation diameter 1 1 mm is used 136 50 52 8 22 Optical communications connection indicator Sensor operation indicator Main display Sub display RIGHT key E...

Page 20: ...erest of product improvement specifications are subject to change without notice Cat No E11E EN 01 OMRON EUROPE B V Wegalaan 67 69 NL 2132 JD Hoofddorf The Netherlands Phone 31 23 568 13 00 Fax 31 23...

Reviews: