background image

1

E3ZM-B

Transparent object detection sensor in compact stainless steel housing

E3ZM-B

The E3ZM-B provides enhanced detection stability for 
the detection of transparent materials. The models for 
all transparent materials allow an easy and intuitive 
adjustment by potentiometer or teach button to adjust 
to individual requirements. The PET optimised model 
provides additional and auto-controlled measures for 
highest stability on PET materials.

• Easy adjustment to individual requirements for all transparent 

materials

• Stable PET detection with optimised detection settings and 

AC

3

power control technology

• Detergent resistant compact SUS316L housing

• Coaxial optics for stable, distance-independant detection

Ordering Information

Features

Enhanced detection stability on PET (PET optimised models)

Robust housing and easy adjustment

Sensor type

Sensing dis-
tance

Special 
reflector

Connection method

Order code

*1

*1.

For ordering pigtail versions contact your OMRON representative. Available options on request are:
- S1J: for M12 4-pin stainless steel plug with 30 cm cable
- S3J: for M8 4-pin stainless steel plug with 30 cm cable
- S5J: for M8 3-pin stainless steel plug with 30 cm cable (only E3ZM-B_T)
- M1J: for M12 4-pin brass plug with 30 cm cable
- M3J: for M8 4-pin brass plug with 30 cm cable
- M5J: for M8 3-pin brass plug with 30 cm cable (only E3ZM-B_T)
- M1TJ: for M12 4-pin brass XS5 click connector plug with 30 cm cable.

NPN output

PNP output

Retro-
reflective 
with M.S.R.

Optimised for 
PET bottles 
and trays

0 to 500 mm 
(teachable)

Order 
separately

*2

*2.

For higher signal stability for PET bottles, order special reflector E39-RP1 separately.

2 m

E3ZM-B61 2M

E3ZM-B81 2M

„

E3ZM-B66

E3ZM-B86

E39-RP1 
included

2 m

E3ZM-B61-C 2M E3ZM-B81-C 2M

„

E3ZM-B66-C

E3ZM-B86-C

For all trans-
parent 
media (glass, 
PET, foils)

0 to 500 mm 
(potentio-
meter ad-
justment)

*3

*3.

Teachable all-transparent-media types are available. Contact your OMRON representative.

Order 
separately

*4

*4.

Order reflector separately.

2 m

E3ZM-B61T 2M E3ZM-B81T 2M

„

E3ZM-B66T

E3ZM-B86T

Utilisation of double reflection effect in PET 
for higher detection stability (PET optimised 
models)

Automatic LED power adjustment (AC

3

) to 

compensate for soiling and temperature 
fluctuations

Detergent and high pressure water resistant 
(see page 9 for more info)

Easy adjustment by potentiometer
or teach button

Summary of Contents for E3ZM-B -

Page 1: ...able S3J for M8 4 pin stainless steel plug with 30 cm cable S5J for M8 3 pin stainless steel plug with 30 cm cable only E3ZM B_T M1J for M12 4 pin brass plug with 30 cm cable M3J for M8 4 pin brass pl...

Page 2: ...Standard surface mount ing pre wired models E39 L150 SUS304 1 set Telescope mounting E39 L43 SUS304 1 Protection wall mounting pre wired models E39 L151 SUS304 1 set E39 L142 SUS304 1 E39 L44 SUS304 1...

Page 3: ...e screw mounting diagonal holes 40x60x7 5 E39 R1S Enhanced detergent resistance PVC Surface screw mounting IP69k after DIN 40050 part 9 40x60x7 5 E39 R50 20x60x6 E39 R51 Highest detergent resistance S...

Page 4: ...rage 35 to 95 with no condensation Insulation resistance 20 M min at 500 VDC Dielectric strength 1 000 VAC 50 60 Hz for 1 min Vibration resistance Destruction 10 to 55 Hz 1 5 mm double amplitude for 2...

Page 5: ...e Y mm Distance Y mm 40 40 0 30 20 10 0 10 20 30 200 400 600 800 1000 1200 1400 1600 Distance X m Y X 2 5 2 0 1 5 1 0 0 5 0 0 2000 500 1000 1500 0 Distance m Excess gain ratio multiple Round 500 ml PE...

Page 6: ...ectric Sensor Main Circuit 1 2 4 3 Light incident Light interrupted ON OFF Operation indicator yellow Between brown 1 and black 4 leads Output transistor Load e g relay Operate Reset ON OFF Light inci...

Page 7: ...ndicator yellow Between blue 3 and black 4 leads Output transistor Load e g relay Operate Reset ON OFF 4 3 2 1 10 to 30 VDC 100 mA max Control output Operation indicator Yellow Stability indicator Gre...

Page 8: ...aching Is Successful When Teaching Is Not Successful The teaching indicator red will go out The Unit will then enter normal operating condi tion The teaching indicator red will flash slowly or quickly...

Page 9: ...or water to enter into the connection between sensor and connec tor RECOMMENDATION To obtain the correct mounting torque a torque wrench may be used 3 Using a M12 or M8 pigtail connector Using a pigta...

Page 10: ...te tightening torque is 0 3 to 0 4 N m When using another commercially available connector follow the usage and tightening torque instructions provided by the manufacturer Load Do not use a load that...

Page 11: ...lector switch 4 dia vinyl insulated round cable with 3 conductors Conductor cross section 0 2 mm2 Insulator diameter 1 1 mm Standard length 2 m 1 3 2 4 M12 x 1 4 dia vinyl insulated round cable with 3...

Page 12: ...ed may be suitable for the products Outdoor use uses involving potential chemical contamination or electrical interference or conditions or uses not described in this document Nuclear energy control s...