background image

10

Transparent object sensor

Safety Precautions

This product is not designed or rated for direct-

ly or indirectly ensuring safety of persons. Do 

not use it for such a purpose.

Do not use the product with voltage in excess 

of the rated voltage. Excess voltage may result 

in malfunction or fire.

Never use the product with an AC power sup-

ply. Otherwise, explosion may result.

When cleaning the product, do not apply a 

high-pressure spray of water to one part of the 

product. Otherwise, parts may become dam-

aged and the degree of protection may be de-

graded.

The following precautions must be observed to ensure safe 

operation of the Sensor.

Operating Environment

Do not use the Sensor in an environment where explosive or 

flammable gas is present.

Connecting Connectors

Be sure to hold the connector cover when inserting or remov-

ing the connector. 

When using an XS3F connector, be sure to tighten the con-

nector lock by hand or preferably with a torque wrench; do not 

use other tools. If too much tightening torque is applied the de-

gree of protection will not be maintained. If the tightening is in-

sufficient, the degree of protection will not be maintained and 

the sensor may become loose due to vibration. The appropri-

ate tightening torque is 0.3 to 0.4 N·m.

When using another, commercially available connector, follow 

the usage and tightening torque instructions provided by the 

manufacturer.

Load

Do not use a load that exceeds the rated load.

Low-temperature Environments

Do not touch the metal surface with your bare hands when the 

temperature is low. Touching the surface may result in a cold 

burn.

Oily Environments

Do not use the Sensor in oily environments. They may dam-

age parts and reduce the degree of protection.

Modifications

Do not attempt to disassemble, repair, or modify the Sensor.

Outdoor Use

Do not use the Sensor in locations subject to direct sunlight.

Cleaning

Do not use thinner, alcohol, or other organic solvents. Other-

wise, the optical properties and degree of protection may be 

degraded.

Cleaning

Do not use highly concentrated cleaning agents. Otherwise, 

malfunction may result. Also, do not use high-pressure water 

with a level of pressure that exceeds the stipulated level. Oth-

erwise, the degree of protection may be reduced.

Surface Temperature

Burn injury may occur. The Sensor surface temperature rises 

depending on application conditions, such as the ambient 

temperature and the power supply voltage. Use caution when 

operating or performing maintenance on the Sensor.

Cable Bending

Do not bend the cable in temperatures of 

25

°

C or below. 

Otherwise, the cable may be damaged.

WARNING

CAUTION

Precautions for Safe Use

Summary of Contents for E3ZM-B -

Page 1: ...able S3J for M8 4 pin stainless steel plug with 30 cm cable S5J for M8 3 pin stainless steel plug with 30 cm cable only E3ZM B_T M1J for M12 4 pin brass plug with 30 cm cable M3J for M8 4 pin brass pl...

Page 2: ...Standard surface mount ing pre wired models E39 L150 SUS304 1 set Telescope mounting E39 L43 SUS304 1 Protection wall mounting pre wired models E39 L151 SUS304 1 set E39 L142 SUS304 1 E39 L44 SUS304 1...

Page 3: ...e screw mounting diagonal holes 40x60x7 5 E39 R1S Enhanced detergent resistance PVC Surface screw mounting IP69k after DIN 40050 part 9 40x60x7 5 E39 R50 20x60x6 E39 R51 Highest detergent resistance S...

Page 4: ...rage 35 to 95 with no condensation Insulation resistance 20 M min at 500 VDC Dielectric strength 1 000 VAC 50 60 Hz for 1 min Vibration resistance Destruction 10 to 55 Hz 1 5 mm double amplitude for 2...

Page 5: ...e Y mm Distance Y mm 40 40 0 30 20 10 0 10 20 30 200 400 600 800 1000 1200 1400 1600 Distance X m Y X 2 5 2 0 1 5 1 0 0 5 0 0 2000 500 1000 1500 0 Distance m Excess gain ratio multiple Round 500 ml PE...

Page 6: ...ectric Sensor Main Circuit 1 2 4 3 Light incident Light interrupted ON OFF Operation indicator yellow Between brown 1 and black 4 leads Output transistor Load e g relay Operate Reset ON OFF Light inci...

Page 7: ...ndicator yellow Between blue 3 and black 4 leads Output transistor Load e g relay Operate Reset ON OFF 4 3 2 1 10 to 30 VDC 100 mA max Control output Operation indicator Yellow Stability indicator Gre...

Page 8: ...aching Is Successful When Teaching Is Not Successful The teaching indicator red will go out The Unit will then enter normal operating condi tion The teaching indicator red will flash slowly or quickly...

Page 9: ...or water to enter into the connection between sensor and connec tor RECOMMENDATION To obtain the correct mounting torque a torque wrench may be used 3 Using a M12 or M8 pigtail connector Using a pigta...

Page 10: ...te tightening torque is 0 3 to 0 4 N m When using another commercially available connector follow the usage and tightening torque instructions provided by the manufacturer Load Do not use a load that...

Page 11: ...lector switch 4 dia vinyl insulated round cable with 3 conductors Conductor cross section 0 2 mm2 Insulator diameter 1 1 mm Standard length 2 m 1 3 2 4 M12 x 1 4 dia vinyl insulated round cable with 3...

Page 12: ...ed may be suitable for the products Outdoor use uses involving potential chemical contamination or electrical interference or conditions or uses not described in this document Nuclear energy control s...

Reviews: