background image

Accessories (Order Separately)

Standard (Straight)

XS2F-D521-DG0-A (L=2 m)
XS2F-D521-GG0-A (L=5 m)

4-to-5 Conductor Conversion Cable

E4PA-C01

Setting Plug

E4PA-P1

45

°

M12

40.7

L

50

30

5

5 dia.

14.9 dia.

6 dia.

18

34

48

300

47.1

45

°

1

2

5

3

4

3

2

4

1

M12

M12

45

°

5 dia.

14.9 dia.

14.9 dia.

5 dia.

6 dia.

25

2.5

10

4.2

10.1 dia.

8 dia.

3.2 dia.

6.9 dia.

In the interest of product improvement, specifications are subject to change without notice.

ALL DIMENSIONS SHOWN ARE IN MILLIMETERS.

To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527.

D099-E1

OMRON Corporation

Industrial Automation Company

Sensing Devices Division H.Q.
Application Sensors Division

Shiokoji Horikawa, Shimogyo-ku,
Kyoto, 600-8530 Japan
Tel: (81)75-344-7068/Fax: (81)75-344-7107

CSM_5_

3

_

10

12

Downloaded from

Arrow.com.

Downloaded from

Arrow.com.

Downloaded from

Arrow.com.

Downloaded from

Arrow.com.

Downloaded from

Arrow.com.

Downloaded from

Arrow.com.

Downloaded from

Arrow.com.

Downloaded from

Arrow.com.

Summary of Contents for E4PA-LS200-M1-N

Page 1: ...cu racy of 1 mm or better has been achieved A setting plug with a temperature compensation function makes it easy to set the sensing range The sensing range can be set by the Setting Plug which is inc...

Page 2: ...180 kHz Approx 85 kHz Approx 65 kHz Response time 63 ms max 195 ms max 440 ms max 850 ms max Power supply voltage 10 to 30 VDC ripple p p 10 max Power consumption 1 800 mW max Analog output Current o...

Page 3: ...ance Y mm Distance X m Y X 1 000 800 600 400 200 0 200 400 600 800 1 000 1 2 3 4 5 6 7 Distance Y mm Distance X m 1 4 2 3 5 E4PA N 0 V Ri 500 Rv 1 000 3 1 2 4 5 10 to 30 V 4 to 20 mA 0 to 10 V Mutual...

Page 4: ...ctor for Sensor I O 5 poles Notch on Sensor RUN indicator yellow Power indicator green RUN indicator yellow Error indicator red Position Function A1 Nearest sensing point A1 A2 Farthest sensing point...

Page 5: ...notch on the Sensor with the A2 triangular mark on the Setting Plug The power indicator green and the A2 RUN indicator yellow will flash showing that the far distance has been correctly set 6 Remove...

Page 6: ...etec tion capability of the Sensor will vary depending on the surface con ditions of the object If the surface irregularities are no more than 0 2 mm then the specified sensing distance will apply Mat...

Page 7: ...indicator red 36 See note 2 25 22 25 5 12 128 27 5 40 dia M30 1 5 M12 1 Two clamping nuts Indicator See note Setting Plug Note 1 RUN indicator yellow Power indicator green Error indicator red 2 This...

Page 8: ...t to change without notice ALL DIMENSIONS SHOWN ARE IN MILLIMETERS To convert millimeters into inches multiply by 0 03937 To convert grams into ounces multiply by 0 03527 D099 E1 OMRON Corporation Ind...

Page 9: ...not described in this catalog Nuclear energy control systems combustion systems railroad systems aviation systems medical equipment amusement machines vehicles safety equipment and installations subj...

Reviews: