background image

In the interest of product improvement, specifications are subject to change without notice.

ALL DIMENSIONS SHOWN ARE IN MILLIMETERS.

To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527.

Cat. No. H141-E1-01A

OMRON Corporation

Industrial Automation Company

Control Devices Division H.Q.
Analog Controller Division
Shiokoji Horikawa, Shimogyo-ku,
Kyoto, 600-8530 Japan
Tel: (81)75-344-7080/Fax: (81)75-344-7189

1105

Warranty and Application Considerations

Read and Understand this Catalog

Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you 
have any questions or comments.

Warranty and Limitations of Liability

WARRANTY
OMRON's exclusive warranty is that the products are free from defects in materials and workmanship for a period of one year (or 
other period if specified) from date of sale by OMRON.
OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, REGARDING NON-INFRINGEMENT, 
MERCHANTABILITY, OR FITNESS FOR PARTICULAR PURPOSE OF THE PRODUCTS. ANY BUYER OR USER 
ACKNOWLEDGES THAT THE BUYER OR USER ALONE HAS DETERMINED THAT THE PRODUCTS WILL SUITABLY MEET 
THE REQUIREMENTS OF THEIR INTENDED USE. OMRON DISCLAIMS ALL OTHER WARRANTIES, EXPRESS OR 
IMPLIED.

LIMITATIONS OF LIABILITY
OMRON SHALL NOT BE RESPONSIBLE FOR SPECIAL, INDIRECT, OR CONSEQUENTIAL DAMAGES, LOSS OF PROFITS, 
OR COMMERCIAL LOSS IN ANY WAY CONNECTED WITH THE PRODUCTS, WHETHER SUCH CLAIM IS BASED ON 
CONTRACT, WARRANTY, NEGLIGENCE, OR STRICT LIABILITY.
In no event shall the responsibility of OMRON for any act exceed the individual price of the product on which liability is asserted.
IN NO EVENT SHALL OMRON BE RESPONSIBLE FOR WARRANTY, REPAIR, OR OTHER CLAIMS REGARDING THE 
PRODUCTS UNLESS OMRON'S ANALYSIS CONFIRMS THAT THE PRODUCTS WERE PROPERLY HANDLED, STORED, 
INSTALLED, AND MAINTAINED AND NOT SUBJECT TO CONTAMINATION, ABUSE, MISUSE, OR INAPPROPRIATE 
MODIFICATION OR REPAIR.

Application Considerations

SUITABILITY FOR USE
OMRON shall not be responsible for conformity with any standards, codes, or regulations that apply to the combination of 
products in the customer's application or use of the products.
Take all necessary steps to determine the suitability of the product for the systems, machines, and equipment with which it will 
be used.
Know and observe all prohibitions of use applicable to this product.
NEVER USE THE PRODUCTS FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY WITHOUT 
ENSURING THAT THE SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS, AND THAT THE OMRON 
PRODUCTS ARE PROPERLY RATED AND INSTALLED FOR THE INTENDED USE WITHIN THE OVERALL EQUIPMENT OR 
SYSTEM.

Disclaimers

PERFORMANCE DATA

Performance data given in this catalog is provided as a guide for the user in determining suitability and does not constitute a 
warranty. It may represent the result of OMRON's test conditions, and the users must correlate it to actual application 
requirements. Actual performance is subject to the OMRON Warranty and Limitations of Liability.

CHANGE IN SPECIFICATIONS
Product specifications and accessories may be changed at any time based on improvements and other reasons. Consult with 
your OMRON representative at any time to confirm actual specifications of purchased product.

DIMENSIONS AND WEIGHTS
Dimensions and weights are nominal and are not to be used for manufacturing purposes, even when tolerances are shown.

Summary of Contents for E5CSZ

Page 1: ...del Number Legend Models with Terminal Blocks 1 Output type R Relay Q Voltage for driving SSR 2 Number of alarms Blank No alarm 1 1 alarm 3 Input type T Thermocouple platinum resistance thermometer multi input 4 Power supply voltage Blank 100 to 240 VAC D 24 VAC VDC 5 Case color Blank Light gray B Black Note A functional explanation is provided here for illustration but models are not necessarily ...

Page 2: ...ption 5 VA 3 VA 2 W Sensor input Multi input thermocouple platinum resistance thermometer type K J L Pt100 Control output Relay output SPST NO 250 VAC 3A resistive load Voltage output for driving the SSR 12 VDC 21 mA with short circuit protection circuit Control method ON OFF or 2 PID with auto tuning Alarm output SPST NO 250 VAC 1A resistive load Setting method Digital setting using front panel k...

Page 3: ...rrent carrying terminals of different polarity Vibration resistance Malfunction 10 to 55 Hz 20 m s2 for 10 min each in X Y and Z directions Destruction 10 to 55 Hz 0 75 mm single amplitude for 2 hr each in X Y and Z directions Shock resistance Malfunction 100 m s2 min 3 times each in 6 directions Destruction 300 m s2 min 3 times each in 6 directions Life expectancy Electrical 100 000 operations mi...

Page 4: ...etting 0 199 9 199 9 0 0 0 0 99 99 99 Setting number 0 1 2 3 4 Minimum setting unit 1 C 0 1 C 1 C 0 1 C 1 C Input Pt100 Temperature range selected using switch 1 000 900 800 700 600 500 400 300 200 100 0 100 850 400 Default setting 0 199 9 200 99 0 0 0 0 99 99 Setting number 0 1 2 3 4 Minimum setting unit 1 C 0 1 C 1 C The shaded value indicates the default setting status Do not set the temperatur...

Page 5: ...polarity 3 The number of alarm outputs none or 1 depends on the model Nomenclature E5CSZ Models with Terminal Blocks 8 9 10 7 6 3 4 5 2 1 1 2 1 2 3 4 5 12 VDC 21 mA Alarm output Alarm output 1 See note 3 Relay output models Voltage output models See note 1 Thermocouple platinum resistance thermometer multi input 100 to 240 VAC 50 60 Hz 24 VAC VDC See note 2 A B B Thermocouple input Relay output Vo...

Page 6: ...cator lights when the setting temperature is being displayed The ALM indicator lights when the alarm value is being displayed PV SP Alarm Value Input Shift Display Alarm indicator ALM1 Alarm 1 Lights when the alarm 1 output is ON Up Key Pressing the Up Key increases the SP alarm value display Keeping the Up Key pressed continues to increase the display value When the internal protect switch is ON ...

Page 7: ...ove 1 999 will be displayed as 2 If unit is changed to 1 degree when the SP and alarm value for the temperature range are displayed in 0 1 units from 0 0 to 199 9 or 0 0 to 99 9 the values will be multiplied by 10 e g 0 5 becomes 5 If the unit is changed in the reverse direction the values will be divided by 10 After changing the range set the SP and alarm value again Input K J L SP range 1 700 1 ...

Page 8: ...ct operation cooling ON Reverse operation heating OFF Input shift display Enabled ON Disabled OFF Tempera ture Sensor selection Multi input thermo couple platinum resistance thermome ter Platinum resis tance thermom eter input ON Thermo couple input OFF Temper ature unit F ON C OFF 6 5 4 3 2 1 ON 6 5 4 3 2 1 ON Set value Alarm type Alarm output operation 0 9 Alarm function OFF OFF 1 Upper and lowe...

Page 9: ... 1 ON 0 100 SP Output level 6 5 4 3 2 1 ON 0 100 SP Output level ST Self tuning Features ST self tuning is a function that finds PID constants by using step response tuning SRT when Controller operation begins or when the set point is changed Once the PID constants have been calculated ST is not executed when the next control operation is started as long as the set point remains unchanged When the...

Page 10: ...ut the shift value is enabled To disable input shift set the input shift value to h0 The shift range depends on the setting unit 5 Protect Switch When the protect switch is ON Up Key and Down Key operations are prohibited to prevent setting mistakes 6 5 4 3 2 1 ON Multi input Thermocouple Platinum Resistance Thermometer Control mode switch 5 OFF Multi input Thermocouple Platinum Resistance Thermom...

Page 11: ...tally Mounting the E5CSZ 1 Insert the E5CSZ into the mounting hole in the panel 2 Push the adapter from the terminals up to the panel and temporarily fasten the E5CSZ 3 Tighten the two fastening screws on the adapter Alternately tighten the two screws little by little to maintain a balance Tighten the screws to a torque of 0 29 to 0 39 N m Tightening screw Tightening screw Adapter Panel ...

Page 12: ...yed as fff The process value is higher than the control temperature range overflow Heating control reverse operation OFF Cooling control direct operation ON PV displayed as The process value is lower than the control temperature range underflow Heating control reverse operation ON Cooling control direct operation OFF fff flashing Multi input Thermocouple platinum resistance thermometer models The ...

Page 13: ...tened from 100 mm to 76 mm Previous model E5CSZ Classification Symbol Meaning Classification Symbol Meaning 1 Control output R Q Relay SPDT single pole double throw Voltage 1 Control output R Q Relay SPST NO single pole single throw normally open Voltage 2 Alarm output 1 One alarm 2 Alarm output Blank 1 No alarms One alarm 3 Input type KJ P Thermocouple K J Platinum resistance thermometer Pt100 JP...

Page 14: ...ance thermometer 100 to 240 VAC 50 60 Hz 24 VAC VDC A B B Thermocouple input Relay output Voltage output Platinum resistance thermometer input 6 5 4 3 2 1 ON Function selection 1 2 3 4 5 6 ON OFF PID PID control ON ON OFF control OFF Control period 2 s ON 20 s OFF Direct reverse opera tion Direct operation cooling ON Reverse operation heating OFF 6 5 4 3 2 1 ON Function selection 1 2 3 4 5 6 ON OF...

Page 15: ... upper limit X SP X ON OFF SP X ON OFF X SP ON OFF X SP X ON OFF X SP X ON OFF X SP ON OFF X SP ON OFF 0 Y ON OFF Function selection 5 6 Temperature Range KJ J 0 to 300 C ON ON K 0 to 999 C OFF ON K 0 to 500 C ON OFF K 0 to 300 C OFF OFF P ON ON Pt100 0 to 300 C OFF ON Pt100 0 0 to 99 0 C ON OFF Pt100 0 0 to 50 0 C OFF OFF 0 1 2 3 4 5 6 7 8 9 Set value Temperature Range 0 Control Mode Switch 5 OFF...

Page 16: ...fective protection against water droplets Terminal Cover Panel Cutout Dimensions E5CSZ 44 8 44 8 84 78 6 48 48 60 min L 48 N 2 5 1 0 Mounting side by side group mounting of N Controllers 45 0 6 0 45 0 6 0 45 0 6 0 L z z E5CSZ Tightening screws 48 76 5 7 5 Adapter for flush mounting Panel Y92F 30 Adapter for flush mounting 58 E5CSZ E5CSZ Adapter for Flush Mounting Provided Note 1 The recommended pa...

Page 17: ...uipment that have an inductance component When a noise filter is used at the power supply first check the voltage or current and attach the noise filter as close as possible to the temperature controller Allow as much space as possible between the Temperature Controller and devices that generate powerful high frequencies high frequency welders high frequency sewing machines etc or surge Do not tou...

Page 18: ...ply shock to them When inserting the Temperature Controller do not allow the electronic components to come into contact with the case 20 Static electricity may damage internal components Always touch grounded metal to discharge any static electricity before handling the Temperature Controller When drawing out the Temperature Controller from the case do not touch the electronic components or patter...

Page 19: ...Temperature Controllers E5CSZ 19 ...

Page 20: ...ice of the product on which liability is asserted IN NO EVENT SHALL OMRON BE RESPONSIBLE FOR WARRANTY REPAIR OR OTHER CLAIMS REGARDING THE PRODUCTS UNLESS OMRON S ANALYSIS CONFIRMS THAT THE PRODUCTS WERE PROPERLY HANDLED STORED INSTALLED AND MAINTAINED AND NOT SUBJECT TO CONTAMINATION ABUSE MISUSE OR INAPPROPRIATE MODIFICATION OR REPAIR Application Considerations SUITABILITY FOR USE OMRON shall no...

Reviews: