CHARACTERISTICS
Measurement precision
Thermocouple:
(
±
0.3% of the measured value or
±
2
°
C, whichever is larger)
±
1 digit max.
(
±
0.3% of the measured value or
±
3.6
°
F, whichever is larger)
±
1 digit max.
Platinum resistance thermometer:
(
±
0.3% of the measured value or
±
0.8
°
C, whichever is larger)
±
1 digit max.
(
±
0.3% of the measured value or
±
1.5
°
F, whichever is larger)
±
1 digit max.
Adjustable sensitivity
0.0
°
C to 99.9
°
C or 0.0
°
F to 99.9
°
F (0.1
°
increments), valid for ON/OFF control only.
Cooling coefficient
0.0 to 10.0 (0.1 increments)
Proportional band
0.0
°
C to 999.9
°
C or 0.0
°
F to 999.9
°
F (0.1
°
increments)
Cooling: cooling coefficient
×
proportional band
Integral time
0 to 3,999 s (1-s increments)
Derivative time
0 to 3,999 s (1-s increments)
Control cycle
Heating or cooling: 1 to 99 s (1-s increments)
Sampling cycle
Approx. 200 ms/8 control points
Dead band/overlap Band
–999
°
to 999
°
(1
°
C or F increments)
Alarm set range
With 1
°
increments: –999
°
to 9,999
°
(0
°
to 9,999
°
with upper/lower limit alarms)
With 0.1
°
increments: –999.9
°
to 9,999.9
°
(0.0
°
to 9,999.9
°
with upper/lower limit alarms)
Fuzzy logic strength
0 to 99% (1% increments)
Fuzzy logic scale 1
0.2
°
to 999.9
°
(0.1
°
C or F increments)
Fuzzy logic scale 2
0.02
°
to 99.99
°
(0.01
°
C or F increments)
SV protection
Lithium battery backup
SV protection time
10 years min. at room temperature
Insulation resistance
20 M
Ω
at 500 VDC between the FG terminal and analog input terminals
Dielectric strength
Leakage current of 1 mA max. between the FG terminal and analog input terminals when 500 VAC
is applied for 1 min.
Vibration resistance
Malfunction: 10 to 55 Hz with 15 m/s
2
(1G) for 10 minutes each in X, Y, and Z directions
Destruction: 10 to 55 Hz with 20 m/s
2
(2G) for 2 hours each in X, Y, and Z directions
Shock resistance
Malfunction: 150 m/s
2
(15.3G) max. 3 times each in
±
X,
±
Y, and
±
Z directions
Destruction: 200 m/s
2
(20.4G) max. 3 times each in
±
X,
±
Y, and
±
Z directions
Enclosure rating
IP00
Weight
Enclosed Unit: 1,700 g max.
Open frame: 900 g max.
EMC
Emission Enclosure
EN55011 Group1 class A
Immunity ESD:
EN61000-4-2:
4 kV contact discharge (level 2)
8 kV air discharge (level 3)
Immunity RF-interference:
ENV50140:
10 V/M amplitude modulated,
80 MHz to 1 GHz (level 3)
10 V/m (pulse modulated, 900 MHz)
Immunity conducted disturbance: ENV50141:
10 V (0.15 to 80 MHz) level 30)
Immunity burst:
EN61000–4–4:
2 kV power line (level 3)
Approved standards
Conforms to EN50081-2, EN50082-2 (See Note 3)
Note: 1. The measurement accuracy of the E5ZE used with a thermocouple B at 400
°
C or 750
°
F max. is not guaranteed. The following
measurement accuracy values are applied to the E5ZE.
K and T at –100
°
C max. and U:
±
3
°
C
±
1 digit max.
K and T at –100
°
F max. and U:
±
5.4
°
F
±
1 digit max.
R, S, and W at 200
°
C max., and B at 1,000
°
C max.:
±
4
°
C
±
1 digit max.
R, S, and W at 400
°
F max., and B at 1,800
°
F max.:
±
7.2
°
F
±
1 digit max.
2. The measurement accuracy of the E5ZE used with any thermocouple is 1
°
C/
°
F. The thermocouple can be used under the fol-
lowing temperature ranges to increase the measurement accuracy to as high as 0.1
°
C/
°
F.
K thermocouple:
0.0
°
C to 1,300.0
°
C, 0.0
°
F to 2,300.0
°
F
T or U thermocouple:
0.0
°
C to 400.0
°
C, 0.0
°
F to 700.0
°
F
N thermocouple:
400.0
°
C to 1,300.0
°
C, 700.0
°
F to 2,300.0
°
F
J, E, L, or PLII thermocouple: Any temperature
3. To ensure EMC conformance, refer to Wiring for Conformance to the EMC Directives at the end of this data sheet.