background image

27

READ AND UNDERSTAND THIS DOCUMENT

Please read and understand this document before using the products. Please consult your OMRON representative if you have any questions or
comments.

WARRANTY

OMRON’s exclusive warranty is that the products are free from defects in materials and workmanship for a period of one year (or other period if
specified) from date of sale by OMRON.

OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, REGARDING NON-INFRINGEMENT,
MERCHANTABILITY, OR FITNESS FOR PARTICULAR PURPOSE OF THE PRODUCTS. ANY BUYER OR USER ACKNOWLEDGES THAT
THE BUYER OR USER ALONE HAS DETERMINED THAT THE PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF THEIR
INTENDED USE. OMRON DISCLAIMS ALL OTHER WARRANTIES, EXPRESS OR IMPLIED.

LIMITATIONS OF LIABILITY

OMRON SHALL NOT BE RESPONSIBLE FOR SPECIAL, INDIRECT, OR CONSEQUENTIAL DAMAGES, LOSS OF PROFITS OR
COMMERCIAL LOSS IN ANY WAY CONNECTED WITH THE PRODUCTS, WHETHER SUCH CLAIM IS BASED ON CONTRACT, WARRANTY,
NEGLIGENCE, OR STRICT LIABILITY.

In no event shall responsibility of OMRON for any act exceed the individual price of the product on which liability is asserted.

IN NO EVENT SHALL OMRON BE RESPONSIBLE FOR WARRANTY, REPAIR, OR OTHER CLAIMS REGARDING THE PRODUCTS UNLESS
OMRON’S ANALYSIS CONFIRMS THAT THE PRODUCTS WERE PROPERLY HANDLED, STORED, INSTALLED, AND MAINTAINED AND
NOT SUBJECT TO CONTAMINATION, ABUSE, MISUSE, OR INAPPROPRIATE MODIFICATION OR REPAIR.

SUITABILITY FOR USE

THE PRODUCTS CONTAINED IN THIS DOCUMENT ARE NOT SAFETY RATED. THEY ARE NOT DESIGNED OR RATED FOR ENSURING
SAFETY OF PERSONS, AND SHOULD NOT BE RELIED UPON AS A SAFETY COMPONENT OR PROTECTIVE DEVICE FOR SUCH
PURPOSES. Please refer to separate catalogs for OMRON's safety rated products.

OMRON shall not be responsible for conformity with any standards, codes, or regulations that apply to the combination of products in the
customer’s application or use of the product.

At the customer’s request, OMRON will provide applicable third party certification documents identifying ratings and limitations of use that apply
to the products. This information by itself is not sufficient for a complete determination of the suitability of the products in combination with the end
product, machine, system, or other application or use.

The following are some examples of applications for which particular attention must be given. This is not intended to be an exhaustive list of all
possible uses of the products, nor is it intended to imply that the uses listed may be suitable for the products:
• Outdoor use, uses involving potential chemical contamination or electrical interference, or conditions or uses not described in this document.
• Nuclear energy control systems, combustion systems, railroad systems, aviation systems, medical equipment, amusement machines, vehicles,

safety equipment, and installations subject to separate industry or government regulations.

• Systems, machines, and equipment that could present a risk to life or property.

Please know and observe all prohibitions of use applicable to the products.

NEVER USE THE PRODUCTS FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY WITHOUT ENSURING THAT
THE SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS, AND THAT THE OMRON PRODUCT IS PROPERLY RATED
AND INSTALLED FOR THE INTENDED USE WITHIN THE OVERALL EQUIPMENT OR SYSTEM.

PERFORMANCE DATA

Performance data given in this document is provided as a guide for the user in determining suitability and does not constitute a warranty. It may
represent the result of OMRON’s test conditions, and the users must correlate it to actual application requirements. Actual performance is subject
to the OMRON Warranty and Limitations of Liability.

CHANGE IN SPECIFICATIONS

Product specifications and accessories may be changed at any time based on improvements and other reasons.

It is our practice to change model numbers when published ratings or features are changed, or when significant construction changes are made.
However, some specifications of the product may be changed without any notice. When in doubt, special model numbers may be assigned to fix
or establish key specifications for your application on your request. Please consult with your OMRON representative at any time to confirm actual
specifications of purchased products.

DIMENSIONS AND WEIGHTS

Dimensions and weights are nominal and are not to be used for manufacturing purposes, even when tolerances are shown.

ERRORS AND OMISSIONS

The information in this document has been carefully checked and is believed to be accurate; however, no responsibility is assumed for clerical,
typographical, or proofreading errors, or omissions.

PROGRAMMABLE PRODUCTS

OMRON shall not be responsible for the user’s programming of a programmable product, or any consequence thereof.

COPYRIGHT AND COPY PERMISSION

This document shall not be copied for sales or promotions without permission.

This document is protected by copyright and is intended solely for use in conjunction with the product. Please notify us before copying or
reproducing this document in any manner, for any other purpose. If copying or transmitting this document to another, please copy or transmit it in
its entirety.

Summary of Contents for EE-SX47 -

Page 1: ...Photomicro Sensors with Built in Amplifier EE SX670 EE SX670 WR EE SX770 EE SX910 R Actual size Be sure to read page 27 before ordering...

Page 2: ...E SX 672 WR EE SX 672 EE SX 673 WR EE SX 673 EE SX 674 WR EE SX 674 EE SX 911 R EE SX 912 R EE SX 913 R EE SX 914 R EE SX 770 EE SX 772 EE SX 771 EE SX 910 R EE SX 675 WR EE SX 675 EE SX 676 WR EE SX...

Page 3: ...hort circuited in advance Appearance Sensing method Connect ing method Sensing distance Output configuration Indicator mode Model NPN output PNP output Through beam type with slot Connector 4 poles Da...

Page 4: ...d models 1 m EE SX673 WR EE SX673P WR Modelswithjunction connectors 0 1 m EE SX673 C1J R EE SX673P C1J R Pre wired models 1 m EE SX674 WR EE SX674P WR Modelswithjunction connectors 0 1 m EE SX674 C1J...

Page 5: ...A max 100 mA load current with a residual voltage of 0 8 V max 40 mA load current with a residual voltage of 0 4 V max PNP open collector 5 to 24 VDC 50 mA max 50 mA load current with a residual volta...

Page 6: ...rminal EE SX670A EE SX671A EE SX672A EE SX673A EE SX674A Light ON Short circuited between terminal and positive terminal Dark ON Open between terminal and positive terminal EE SX470 EE SX471 EE SX472...

Page 7: ...X674R Light ON Short circuited between terminal and positive terminal Dark ON Open between terminal and positive terminal EE SX470P EE SX471P EE SX472P EE SX473P EE SX474P Light ON Incident Interrupte...

Page 8: ...ptical axis Two 3 2 dia holes Terminal Arrangement L Terminal needs no connection for all EE SX47 series sensors 1 Vcc 2 L L 3 OUT OUTPUT 4 GND 0 V EE SX672 672P EE SX672A 672R EE SX472 472P 19 13 4 5...

Page 9: ...2 3 7 0 8 2 13 19 5 0 3 0 7 6 3 6 10 6 35 Indicator window Optical axis Optical axis Detection window 2 3 1 4 16 7 13 2 54 22 2 9 6 2 3 8 EE SX676 676P Terminal Arrangement 1 Vcc 2 L L 3 OUT OUTPUT 4...

Page 10: ...oles Robot cable with 2 8 dia 4 conductors conductor cross section 0 15 mm2 insulator diameter 0 8 mm Standard length 1 m EE SX672 WR 672P WR EE SX672 C1J R 672P C1J R Terminal Arrangement Brown 1 Vcc...

Page 11: ...with 2 8 dia 4 conductors conductor cross section 0 15 mm2 insulator diameter 0 8 mm Standard length 1 m EE SX676 WR 676P WR EE SX676 C1J R 676P C1J R Terminal Arrangement Brown 1 Vcc Pink 2 L Blue 3...

Page 12: ...2 L Pink 3 OUT Black 4 Blue 1 2 R1 2 5 5 R3 10 2 19 4 21 9 15 25 2 19 12 3 2 2 1 3 3 3 6 3 4 Four R1 6 Connector Hold down Clip EE 1006A Materials Stainless steel Connector with Cable EE 1010 Connect...

Page 13: ...h Sensing distance Output configuration Indicator mode 1 Model NPN output PNP output Standard Through beam type with slot 2 m Dark ON Incident light EE SX770 EE SX770P No incident light EE SX770A EE S...

Page 14: ...3 m EE SX770A ECON 0 3M 2 m EE SX770A ECON 2M Light ON Incident light 0 3 m EE SX870 ECON 0 3M 2 m EE SX870 ECON 2M No incident light 0 3 m EE SX870A ECON 0 3M 2 m EE SX870A ECON 2M L shaped Dark ON...

Page 15: ...dels Control output NPN open collector 5 to 24 VDC 100 mA max 100 mA load current with a residual voltage of 0 8 V max 40 mA load current with a residual voltage of 0 4 V max PNP open collector 5 to 2...

Page 16: ...Interrupted ON OFF ON OFF Operates Releases Light indicator red Output transistor Load e g relay 1 2 3 4 Light indicator red Load Main circuit Blue GND Brown Vcc Black OUT control output 100 mA max 5...

Page 17: ...4 VDC 4 3 1 Light indicator red Output transistor Load e g relay Incident Interrupted ON OFF ON OFF Operates Releases Light indicator red Output transistor Load e g relay Incident Interrupted ON OFF O...

Page 18: ...xis 12 5 2 9 9 0 3 0 3 4 L shaped EE SX771 771P EE SX871 871P EE SX771A 771R EE SX871A 871R Indicator window Vinyl insulated round cable of 2 4 dia 3 cores 0 08 mm2 with 0 7 mm dia insulator Standard...

Page 19: ...h Light ON and Dark ON Outputs Both light ON and dark ON outputs are provided on all models allowing outputs to be switched by simply changing the wiring according to the application Indicator Visible...

Page 20: ...1J R EE SX910P C1J R L shaped Pre wired models 1 m EE SX911 R EE SX911P R Models with junction connectors 0 3 m EE SX911 C1J R EE SX911P C1J R F shaped Pre wired models 1 m EE SX912 R EE SX912P R Mode...

Page 21: ...output reverse polarity protection Response frequency 3 kHz min 8 kHz average Light incident 15 s average light interrupted 40 s average Ambient illumination 1 000 lx max with fluorescent light on the...

Page 22: ...SX914P R EE SX914P C1J R 0 1 2 3 4 5 6 Dark ON Light ON Distance d mm Insertion direction d 0 1 2 3 4 5 6 d Dark ON Light ON Insertion direction Distance d mm 0 1 2 3 4 5 6 Dark ON Light ON Insertion...

Page 23: ...ence to the following example The resistance of the resistor is generally 4 7 k and its wattage is 1 2 W for a supply voltage of 24 V and 1 4 W for 12 V Example EE SX91 Series Load Resistance of 4 7 k...

Page 24: ...cable of 2 8 dia 4 cores 0 15 mm2 with 0 8 mm dia insulator Standard length 1 m 1 2 3 4 Terminal 1 2 3 4 V OUTPUT 2 0 V OUTPUT 1 Specifications EE SX912 R EE SX912P R EE SX912 C1J R EE SX912P C1J R I...

Page 25: ...DC Power Supply of 30 V or Less 1 When connected to one of the circuits Class 2 described in 1 2 and 3 below a sensor can be used even if it is not UL certified Use the following UL certified products...

Page 26: ...ay be suitable for the products Outdoor use uses involving potential chemical contamination or electrical interference or conditions or uses not described in this document Nuclear energy control syste...

Page 27: ...Business Unit Carl Benz Str 4 D 71154 Nufringen Germany Tel 49 7032 811 0 Fax 49 7032 811 199 OMRON ELECTRONICS LLC 1 East Commerce Drive Schaumburg IL 60173 U S A Tel 1 847 843 7900 Fax 1 847 843 85...

Reviews: