206
Parameters That Can Be Allocated for Programless Communications
Appendix
Parameters That Can Be Allocated for Programless
Communications
The following table lists the parameters that can be allocated to programless communications.
Function
Parameter
Attribute
Upload
Download
Remarks
Status
Device A Status
Common
●
--- (See note.)
Monitoring only
Device Error Status
Common
●
--- (See note.)
Monitoring only
Configuration Error A Status
Common
●
--- (See note.)
Monitoring only
Configuration Error B Status
Common
●
--- (See note.)
Monitoring only
Internal Communications Error Status
Common
●
--- (See note.)
Monitoring only
Error Channel A Status
Common
●
--- (See note.)
Monitoring only
Error Channel B Status
Common
●
--- (See note.)
Monitoring only
Error Channel C Status
Common
●
--- (See note.)
Monitoring only
Error Channel D Status
Common
●
--- (See note.)
Monitoring only
Basic Unit/Expand Unit Error
Common
●
--- (See note.)
Monitoring only
Basic Unit/Expand Unit Alarm
Common
●
--- (See note.)
Monitoring only
Decimal Point Monitor
Common
●
--- (See note.)
Monitoring only
Device B Status
Common
●
--- (See note.)
Monitoring only
Number of Gradient Channels Monitor
Common
●
--- (See note.)
Monitoring only
HB Alarm
Heater Current Value Monitor
CH
●
--- (See note.)
Monitoring only
Leakage Current Value Monitor
CH
●
--- (See note.)
Monitoring only
Heater Burnout Detection
CH
●
●
HS Alarm
CH
●
●
Monitoring
Process Value
CH
●
--- (See note.)
Monitoring only
Channel Status
CH
●
--- (See note.)
Monitoring only
Channel Alarm Status
CH
●
--- (See note.)
Monitoring only
Internal SP
CH
●
--- (See note.)
Monitoring only
Bank No. Monitor
CH
●
--- (See note.)
Monitoring only
MV Monitor (Heating)
CH
●
--- (See note.)
Monitoring only
Target value
Bank 0 to 3 Present Bank Set Point
BANK
●
●
Bank 0 to 3 Present Bank SP Ramp Rise Value
BANK
●
●
Bank 0 to 3 Present Bank SP Ramp Fall Value
BANK
●
●
SP Upper Limit
CH
●
●
SP Lower Limit
CH
●
●
Alarms
Bank 0 to 3 Present Bank Alarm Value 1
BANK
●
●
Bank 0 to 3 Present Bank Alarm Upper Limit Value 1
BANK
●
●
Bank 0 to 3 Present Bank Alarm Lower Limit Value 1
BANK
●
●
Bank 0 to 3 Present Bank Alarm Value 2
BANK
●
●
Bank 0 to 3 Present Bank Alarm Upper Limit Value 2
BANK
●
●
Bank 0 to 3 Present Bank Alarm Lower Limit Value 2
BANK
●
●
Bank 0 to 3 Present Bank Alarm Value 3
BANK
●
●
Bank 0 to 3 Present Bank Alarm Upper Limit Value 3
BANK
●
●
Bank 0 to 3 Present Bank Alarm Lower Limit Value 3
BANK
●
●
Inputs
Input Value 1 for Input Correction
CH
●
●
Input Shift 1
CH
●
●
Input Value 2 for Input Correction
CH
●
●
Input Shift 2
CH
●
●
Summary of Contents for EJ1G
Page 3: ...iv ...
Page 17: ...xviii ...
Page 21: ...xxii ...
Page 53: ...32 Unit Configuration Examples Section 2 4 ...
Page 69: ...48 Changing SPs During Operation Section 3 3 ...
Page 81: ...60 Other Functions Section 4 5 ...
Page 145: ...124 Other HFU Functions Section 5 7 ...
Page 167: ...146 Detailed Description of Services Section 6 4 ...
Page 229: ...208 Parameters That Can Be Allocated for Programless Communications Appendix ...
Page 237: ......