Modular Temperature Controller

 

EJ1

Ratings

Note: 1.

Auxiliary outputs can be allocated using digital output allocations.

2.

Event inputs can be allocated using digital output allocations. 

Characteristics

Communications Characteristics: Port C 

When using an HFU, port B on the End Plate can be used for distributed placement only. 

Note: 1.

The communications method can be switched between RS-485 and RS-232C. A separate model must be used for RS-422 communications. 

2.

For the number of Units that can be connected, refer to 

Connection Precautions

 on page 11.

HFU Unit/EJ1

N

-HFU

Power supply voltage

24 VDC

Operating voltage range

85% to 110% of rated voltage

Power consumption

2 W max. (at maximum load)

Auxiliary outputs 
(See note 1.)

Outputs

4

Transistor outputs

Max. operating voltage: 30 VDC, Max. load current: 50 mA

Event inputs (See 
note 2.)

Inputs

4

Contact inputs

ON: 1 k

 max., OFF: 100 k

 min.

Transistor inputs

ON: residual voltage of 1.5 max., OFF: leakage current of 0.1 mA max. 

Short-circuit current: Approx. 4 mA (per contact) 

Programless 
connection

Programless downloading 
(EJ1 reads data from a PLC)

Number of parameters that can be set:  600 

 

300 (Ver. 1.0)

Programless uploading 
(EJ1 writes data to a PLC)

Number of parameters that can be set:  600 

300 (Ver. 1.0)

Applicable PLCs

OMRON: SYSMAC CS/CJ/CP1H Series

Mitsubishi Electric: MELSEC-An/AnS/FX

3UC

 Series 

Mitsubishi Electric: MELSEC-Q/QnA/QnAS Series (Ver. 1.0)

Ambient temperature range

Operating: 

10°C to 55°C

Storage: 

25°C to 65°C (with no icing or condensation)

Ambient humidity range

Operating: 25% to 85% (with no condensation)

Insulation resistance

20 M

 min. (at 500 VDC)

Dielectric strength

600 VAC, 50/60 Hz for 1 min between current-carrying terminals of different polarity

Vibration resistance

10 to 55 Hz, 20 m/s

2

 for 2 hours each in X, Y, and Z directions

Shock resistance

150 m/s

2

 max., 3 times each in 6 directions

Weight

160 g

Degree of protection

Rear case: IP20, Terminal section: IP00

Memory protection

EEPROM (non-volatile memory) (number of writes: 100,000)

Standards

Approved standards

UL61010C-1, CSA C22.2 No.1010-1

Conformed standards

EN61010-1 (IEC61010-1): Pollution level 2, overvoltage category II

EMC Directive

Refer to page 3.

Transmission path connection

RS-485/RS-422: Multi-point, RS-232C: Point-to-point (See note 1.)

Communications method

RS-485/RS-422 (two-wire, half duplex), RS-232C

Synchronization method

Start-stop synchronization

Communications protocol

OMRON PLC protocol (Connectable PLCs: SYSMAC CS/CJ/CP1H Series)

AnA/AnU CPU common commands (Connectable PLCs: MELSEC-An/AnS/FX

3UC 

Series) 

MC protocol (form 5) (Connectable PLCs: MELSEC-Q/QnA/QnAS Series)

Baud rate

9.6, 19.2, 38.4, 57.6, or 115.2 kbps

Transmission code

Binary

Data bit length

8 bits

Stop bit length

1 bit

Error detection

Depends on protocol selected for the programless communications protocol.

Flow control

None

Interface

RS-485, RS-422, RS-232C (See note 1.)

Retry function

Available

Communications response wait time

0 to 99 ms (default: 5 ms)
1 to 99 ms (default: 5 ms) (Ver. 1.0)

Number of Basic Units that can be connected in 
parallel (See note 2.)

16 Units (model numbers with TC4: 64 channels, model numbers with TC2: 32 channels)

Number of HFUs that can be connected 

SYSMAC CS/CJ-series PLCs: 8 (EJ1-HFU

@

-NFLK)

MELEC Q/QnA/QnAS-series PLCs: 8 (EJ1-HFU

@

-NFL2 )

V1.1

V1.1

V1.1

V1.1

V1.1

V1.1

Summary of Contents for EJ1N-TC2

Page 1: ...se a Current Transformer E54 CT1 or E54 CT3 separately 4 There are three operation instructions that can be sent to Basic Units connected to an HFU Functional Upgrades Refer to page 17 for details Upg...

Page 2: ...urrent input 150 max voltage input 1 M min Control outputs Voltage output Output voltage 12 VDC 15 max load current 21 mA PNP models with short circuit protection circuit Transistor output Max operati...

Page 3: ...s of 1 s Derivative time D 0 0 to 999 9 s in units of 0 1 s Control period 0 5 s 1 to 99 s in units of 1 s Manual reset value 0 0 to 100 0 in units of 0 1 Alarm output setting range 1 999 to 9 999 dec...

Page 4: ...r odd Vertical parity even Block check character BCC with CompoWay F CRC 16 with Modbus Flow control None Interface RS 485 Retry function None Communications response wait time 0 to 99 ms default 5 ms...

Page 5: ...0 mA 0 to 20 mA 1 to 5 V 0 to 5 V 0 to 10 V Tem pera ture range C 2300 1800 1700 1600 1500 1400 1300 1200 1100 1000 900 800 700 600 500 400 300 200 100 0 100 0 200 0 2300 Any of the following ranges b...

Page 6: ...h no condensation Insulation resistance 20 M min at 500 VDC Dielectric strength 600 VAC 50 60 Hz for 1 min between current carrying terminals of different polarity Vibration resistance 10 to 55 Hz 20...

Page 7: ...icing or condensation Ambient humidity range Operating 25 to 85 with no condensation Insulation resistance 20 M min at 500 VDC Dielectric strength 600 VAC 50 60 Hz for 1 min between current carrying t...

Page 8: ...ON SW2 2 1 3 4 5 6 7 8 EJ1 TC4 0 1 2 3 4 5 6 7 8 9 A BCDE F PC PLC PT PC EJ1N TC4 or EJ1N TC2 EJ1C EDU Port A connector USB connection can be made with the E58 CIFQ1 sold separately CX Thermo for sett...

Page 9: ...SW1 ERROR OCC SD RD READY SW2 SW1 ERROR OCC SD RD READY G3ZA G3ZA PC EJ1N HFU PLC EJ1N TC4 or EJ1N TC2 EJ1C EDU Port B RS 232C Port B is used for distributed placement Port A connector USB connection...

Page 10: ...3 PWR RUN ERR ALM SW1 ON SW2 2 1 3 4 5 6 7 8 EJ1 TC4 0 1 2 3 4 5 6 7 8 9 A B C DEF COM1 COM2 COM3 PWR RUN ERR ALM SW1 ON SW2 2 1 3 4 5 6 7 8 EJ1 HFU 0 1 2 3 4 5 6 7 8 9 A B C DEF CX Thermo for setting...

Page 11: ...M3 PWR RUN ERR ALM SW1 ON SW2 2 1 3 4 5 6 7 8 EJ1 TC4 0 1 2 3 4 5 6 7 8 9 A BCDE F EJ1C EDU Up to 8 G3ZA Power Controllers can be connected to one Basic Unit EJ1N TC4 or EJ1N TC2 G3ZA G3ZA connection...

Page 12: ...ALM SW1 ON SW2 2 1 3 4 5 6 7 8 EJ1 HFU 0 1 2 3 4 5 6 7 8 9 A BCDE F EJ1N HFU EJ1C EDU Name Model No Communications ports Port 1 Port 2 Serial Communications Units CJ1W SCU21 V1 RS 232C RS 232C CJ1W SC...

Page 13: ...nel 1 Channel 2 Q compatible Serial Communications Unit QJ71C24N QJ71C24 RS 232C RS 422 485 QJ71C24N R2 QJ71C24 R2 RS 232C RS 232C QJ71C24N R4 RS 422 485 RS 422 485 QnA compatible Serial Communication...

Page 14: ...The Temperature Controller can be connected to a computer using USB 3 Models with screw less clamp terminals have terminals A10 and B10 but they are not used Do not connect anything to them 12 VDC 12...

Page 15: ...ors COM1 COM2 COM3 Operation Indicators PWR RUN ERR ALM SW1 SW2 Operation Indicators Meaning PWR green Lit while the power is ON RUN green Lit during operation ERR red Flashes or lights when an error...

Page 16: ...e factory setting is unit number 01 SW2 Settings EJ1N TC2 TC4 EJ1N HFU SW2 SW1 1 2 0 1 2 3 4 5 6 7 8 9 A B C D E F OFF OFF 00 01 02 03 04 05 06 07 08 09 10 11 12 13 14 15 ON OFF 16 17 18 19 20 21 22 2...

Page 17: ...d for programless up down setting has been increased to 600 each Connection now possible to MELSEC QnA An AnS FX3uc series PLCs A new setting read operation has been added to programless communication...

Page 18: ...OM2 COM3 PWR RUN ERR ALM SW1 ON SW2 2 1 3 4 5 6 7 8 0 1 2 3 4 5 6 7 8 9 A B C DEF COM1 COM2 COM3 EJ1N EJ1N PWR RUN ERR ALM SW1 ON SW2 2 1 3 4 5 6 7 8 109 Models with screw terminal blocks 104 85 Model...

Page 19: ...rox 6 dia E54 CT3 Accessory Armature Plug Rail Mounting Equipment Order Separately DIN Rail PFP 100N PFP 50N Note The figures in parentheses are dimensions for the PFP 50N 4 5 15 25 25 10 10 1000 500...

Page 20: ...hase Ultra compact and slim model combined with a heat radiator Rated input voltage 12 to 24 VDC 240 VAC 15 A 25 A 35 A or 45 A 480 VAC 15 A 25 A 35 A or 45 A G3PB Three Phase Three phase batch contro...

Page 21: ...ON power to the product 14 Never touch the electronic components connectors or patterns on product boards with your bare hands Always hold the product by the case Inappropriately handling the product...

Page 22: ...cy 1 When extending or connecting the thermocouple lead wire be sure to use compensating wires that match the thermocouple types 2 When extending or connecting the lead wire of the platinum resistance...

Page 23: ...50 cm Connecting to the G3ZA EJ1N TC Refer to the G3ZA Instruction Manual for wiring methods Lower the lever Pull out 1 Lower the hooks 3 Press in on the Unit 2 Catch the upper hook onto the DIN Rail...

Page 24: ...ent or addition to the above warranty See http oeweb omron com or contact your Omron representative for pub lished information 14 Limitation on Liability Etc OMRON COMPANIES SHALL NOT BE LIABLE FOR SP...

Page 25: ...nquiries 800 556 6766 OMRON CANADA INC 885 Milner Avenue Toronto Ontario M1B 5V8 Tel 416 286 6465 MEXICO SALES OFFICES Mexico D F 555 660 3144 Ciudad Ju rez 656 623 7083 Monterrey N L 818 377 4281 Que...

Reviews: