5-6
Section
Multi-vendor Applications
50
Item
ID content
Get
(read)
Set
(write)
Value
Object
i
t
Attribute
1 State
Yes
No
---
j
instance
3
2 Instance type
Yes
No
01 (hexadecimal)
3
3 Transport class trigger
Yes
No
82 (hexadecimal)
4 Produced connection
ID
Yes
No
---
5 Consumed connection
ID
Yes
No
---
6 Initial comm.
characteristics
Yes
No
02 (hexadecimal)
7 Produced connection
size
Yes
No
See note.
8 Consumed connection
size
Yes
No
0800
(hexadecimal)
9 Expected packet rate
Yes
Yes
---
12 Watchdog time-out
action
Yes
No
00
13 Produced connection
path length
Yes
No
0600
14 Produced connection
path
Yes
No
20_04_24_01_30
_03
15 Consumed
connection path length
Yes
No
0000
16 Consumed
connection path
Yes
No
No data
17 Production inhibit
time
Yes
No
00
Note
Indicates the number of input bytes used by the Slave. The left-
most and rightmost bytes are reversed. (For example, the pro-
duced connection size = 0800 when 8 bytes are used.)
With the bit-strobed interface, the maximum produced connec-
tion size is 8 bytes. A produced connection size of 8 bytes (0800)
will be used if a higher value has been set for the number of input
bytes with the user MPU; the set value will be used if it is 8 bytes
or less.
Item
DeviceNet service
Parameter option
Object
i
t
Service
05
Reset
No
j
instance
3
0E
Get_Attribute_Single
No
3
10
Set_Attribute_Single
No
Summary of Contents for F150-2
Page 1: ...Cat No Z132 E1 02 Manual 1 SETUP MANUAL F150 2 Vision Sensor...
Page 2: ......
Page 3: ...F150 2 Vision Sensor Setup Manual Revised May 2004...
Page 4: ...vi...
Page 10: ......
Page 14: ......
Page 20: ......
Page 72: ......
Page 84: ......
Page 86: ......
Page 87: ......
Page 88: ...Z132 E1 02...