background image

 
 

 

Distance settable Photoelectric Sensor 

 

F3C-AA42-1

 

F3C-AA42-3J

 

 

 

Product specifications subject to change without notice 

 

Datenblatt f3c-aa42-3j/ 01.12.98 

 

1 / 8

Stable Detection Background-Suppression-Type 
 

• 

Background influences are eliminated by a unique optical system for setting the detection distance 

 

• 

Small black-/white-error 
 

• 

Independant against ambient light 

 

• 

Sensing distance mechanically adjustable: 
BGS setting distance:  150... 900 mm 
Detecting distance: 

0 -750 mm 

 

• 

Small housing-case specially designed for conveyer-application (only 8 
mm of thickness on the top of the housing) 
 

• 

Nearly no blind-zone by using additional receiver 
 

• 

Easy BGS-adjustment by 6-turn-knob 
 

• 

Sensitivity adjustment for near side detector 
 

• 

Stability function indication by blinking LED 
 

• 

Integrated jamming control unit (Only F3C-AA42-3J) 
 

• 

Confirms to relevant EN/IEC standards, CE 

 

 

Example for sensing characteristics (detection 
area) in conveyer application and description of 
setting the minimum and maximum 
Background Suppression (BGS) function

 

 

Summary of Contents for F3C-AA42-1

Page 1: ...S setting distance 150 900 mm Detecting distance 0 750 mm Small housing case specially designed for conveyer application only 8 mm of thickness on the top of the housing Nearly no blind zone by using...

Page 2: ...ment instruction manual Ratings Characteristics Item F3C AA42 1 F3C AA42 3J Power supply voltage 10 to 30 VDC ripple 10 max Current consumption 40 mA max Settable distance for background suppression 1...

Page 3: ...perating range Sn 20 cm 45 cm 60 cm 75 cm Reflecting object Kodak Gray Card 90 reflectivity 200 mm x 200 mm F3C Spotdiameter via detection distance 0 0 5 1 1 5 2 2 5 3 3 5 4 4 5 0 10 20 30 40 50 60 70...

Page 4: ...S Conveyor Sensor 1 Vertical detection 2 Horizontal detection Reflecting object Kodak Gray Card 90 reflectivity 200 mm x 200 mm Vertical F3C Vertical detection angle 2 0 1 5 1 0 0 5 0 0 0 5 1 0 1 5 2...

Page 5: ...0 40 50 60 70 80 15cm 30cm 45cm 60cm 75cm BGS Setting distance Sensing distance cm 18 6 3 90 Pos Functional description 10 IR emitting LED 20 Near side detector 30 Optical module 40 Black coloured adj...

Page 6: ...V Valve bn bk ye bl bk Timing chart Light is not received red OFF OFF Release Jamming control connections and principal circuit Only F3C AA42 3J F3C AA42 3J Plug for power supply Socket for neighbouri...

Page 7: ...object is detected Otherwise increase sensitivity by turning the yellow knob clockwise 8 When object is removed the red LED should not light or blink Recommended adjustment The adjusted sensing dista...

Page 8: ...urfaces should be cleaned from time to time by using a soft cloth Startup Operation A maximum of 300 ms is required from the time power is turned on until F3C is able to detect objects If power is sup...