background image

F

3

C-AL

A-177

F3C-AL

Distance setting laser photoelectric sensor

F3C-AL

• 700 mm max setting distance
• small visible Laser light spot for simple

adjustment

Features

Clear red spot ensures easy setting.

With its wide setting range 170 to 700 mm, F3C-AL is compat-

ible with standard conveyors. In the setting distance of 700

mm, the distance can be set easily with a 1.5x4 mm red spot.

Secure detection of shiny surface

Ensures stable detection of a 45-degree shiny surface. Detec-

tion of pouches, laminated packages or like minimizes setup

change time.

Unaffected by a shiny background.

Insensitive to shiny objects in the background, the Sensor can

be installed in any place.

Small Black/White error:
2% (Setting distance 300 mm), 
8% max. (Setting distance 500 mm)

A little black/white error saves adjustment time during setup

change.

Full hysteresis detection range 0.5% max. 
(for white paper)

6-turn adjuster ensures ease of adjustment.

700mm

170mm

Summary of Contents for F3C-AL

Page 1: ...x4 mm red spot Secure detection of shiny surface Ensures stable detection of a 45 degree shiny surface Detec tion of pouches laminated packages or like minimizes setup change time Unaffected by a shin...

Page 2: ...being transferred Since it is a reflection type a viewport is OK with one place F3C Wafer Detection of wafers through view port Reflective model Red light 120 170 Setting range 120 to 700 mm Sensing...

Page 3: ...ax residual voltage 2 V max PNP open collector output type Light ON Dark ON cable connection selectable Protective circuits Reverse polarity protection output short circuit protection mutual interfere...

Page 4: ...Setting distance mm 20 15 10 5 0 150 200 300 400 500 600 700 Sensing object White paper reflectivity 90 Black paper reflectivity 5 Black and white error 800 700 600 500 400 300 200 100 0 90mm 50mm 185...

Page 5: ...transistor Load Relay 10 to 30 VDC Main circuit Load Relay Operation selectable 150 mA max Light indicator red Stability indicator green 0V ZD 1 4 3 2 Connector Pin Arrangement 3 1 2 4 10 to 30 VDC I...

Page 6: ...ground object Remove the detected object and turn the adjustment knob clockwise until the LIGHT indicator red lights This is the position B Then turn the adjustment knob coun terclockwise until the LI...

Page 7: ...has load short circuit protection If a load short circuit or like has occurred the output turns OFF Therefore recheck the wiring and switch power on again This resets the short circuit protection cir...

Page 8: ...than spot diameter Correct operation The moving direction of the sensor or object should be prefer ably along the optical axis of the light beam Lateral approach is also possible Movement from the top...

Reviews: