background image

5

F3E

 Multibeam sensor

Installation Kit S

Installation Kit M

cone

M5x16

M4x10

M4x12

M4x12

M6x16

u

pper 

mo

u

nting 

a

ngle

vertic

a

mo

u

nting 

a

ngle

s

en

s

or 

u

nit with 

mo

u

nting 

s

tr

a

fix

a

tion

vertic

a

l

mo

u

nting 

a

ngle

lower 
mo

u

nting 

a

ngle

s

en

s

or 

u

nit with 

mo

u

nting 

s

tr

a

fix

a

tion

The 

u

pper mo

u

nting 

a

ngle i

s

 

s

crewed

to the top of the door oper

a

tor.

The lower mo

u

nting 

a

ngle i

s

 

s

crewed

to the 

u

nder

s

ide of the door 

s

ill.

Then the vertic

a

l mo

u

nting 

a

ngle

- with the 

s

en

s

or 

u

nit 

a

lre

a

dy 

s

crewed onto it -

i

s

 in

s

erted with it

s

 conic

a

l end into the 

s

lot

in the lower mo

u

nting 

a

ngle.

s

en

s

or 

u

nit with 

s

tr

a

p fix

a

tion

mo

u

nting cl

a

mp

s

door p

a

nel

Summary of Contents for F3E

Page 1: ...ceiver cut off can be monitored by control unit Ray failure toleration As soon as one channel is not switching for more than 60 seconds the F3E identifies a defect and deac tivates this channel The sensor then functions normally again showing the defect channel by a red error LED Easy parameterization By test input of transmitter a parameterization of L ON D ON operation and shading of LED areas i...

Page 2: ...conformity standards 73 23 EWG 89 336 EWG 95 16 EG EN81 1 EN81 2 EN12015 EN12016 EN61000 6 x Protective degree IP54 Connection methods Pre wire type 5 m PVC cable M8 4 PIN Indicator LEDs Emitter power indicator yellow Receiver output indicator yellow output indicator red Error status indication Red LED blinking unstable operation contamination max exceeding sensing dis tance Red LED ON yellow LED ...

Page 3: ...er 1 2 3 4 Connector PIN Arrangement Power indicator green 1 2 3 4 10 to 30 V DC 0 V brown white black not used blue Main circuit alternatively test input and programming Transmitter 1 2 3 4 Connector PIN Arrangement a1 a2 a3 a4 a5 h LED red light rays LED yellow 9 8 7 6 5 4 3 2 1 5 5 ø 4 5 Dimension F3E 16 F3E 46 a5 25 mm 25 mm a4 690 mm 650 mm a3 640 mm 650 mm a2 690 mm 650 mm a1 25 mm 25 mm h 2...

Page 4: ...m line angled M8 PVC 4 5 no brass XS3F M422 405 A robotic cable straight M8 PVC 4 5 no brass XS3F M421 405 R robotic cable angled M8 PVC 4 5 no brass XS3F M422 405 R Item Description Order reference F3E Installation Kit S Installation kit for stationary mounting on lift doors F3E IK S F3E Installation Kit M Installation kit for mounting to mobile doors panels F3E IK M F3E Power supply Power supply...

Page 5: ...wer mounting angle sensor unit with mounting strap fixation The upper mounting angle is screwed to the top of the door operator The lower mounting angle is screwed to the underside of the door sill Then the vertical mounting angle with the sensor unit already screwed onto it is inserted with its conical end into the slot in the lower mounting angle sensor unit with strap fixation mounting clamps d...

Page 6: ...nsor Do not strike the Photoelectric Sensor with a hammer or any other tool during the installation of the Sensor Cleaning Never use paint thinners or other organic solvents to clean the surface of the product M8 Connector Always turn OFF the power supply to the Sensor before con necting or disconnecting the metal connector Hold the con nector cover to connect or disconnect it Secure the connector...

Reviews: