Alert statements in this manual
2
2-6
Precautions for Safe Use
Make sure to observe the following precautions that are necessary for ensur-
ing safe use of the product.
• Thoroughly read this manual and understand the installtion procedures,
operation check procedures, and maintenance procedures before using
the product.
• Loads must satisfy both of the following conditions:
• Not short-circuited
• Not used with a current that is higher than the rating
• Do not drop the product
• Dispose of the product in accordance with the relevant rules and regula-
tions of the country or area where the product is used.
2-7
Precautions for Correct Use
Observe the precautions described below to prevent operation failure, mal-
functions, or undesirable effects on product performance.
2-8
Installation environment
Do not install the F3S-TGR-CL system in the following types of environments:
• Areas exposed to intense interference light, such as direct sunlight
• Areas with high humidity where condensation is likely to occur
• Areas where corrosive gases are present
• Areas exposed to vibration or shock levels higher than in the specification
provisions
• Areas where the product may come into contact with water
• Areas where the product may come into contact with oil that is an
adhesive solvent
Do not use radio equipment such as cellular phones, walkie-talkies, or trans-
ceivers near the F3S-TGR-CL system.
2-9
Wiring and installation
• Make sure to perform wiring while the power supply is OFF. Otherwise,
the F3S-TGR-CL system may fail to operate due to the diagnosis func-
tion.
• When replacing the cable connectors with other types of connectors, use
connectors that provide a proper grade of protection.
• Properly perform the wiring after confirming the signal names of all the
terminals.
• Do not operate the control system until 2 seconds or more (2.2 seconds
or more in case of series connection) after turning ON the power of the
F3S-TGR-CL system.
• Be sure to route the F3S-TGR-CL system cable separate from high-
potential power lines or through an exclusive conduit.
• When using a commercially available switching regulator power supply,
make sure to ground the FG terminal (frame ground terminal).
• Install the transmitter and receiver so that their vertical direction should
match.
!WARNING
When substituting/replacing the F3S-TGR-CL system with an equivalent F3S-
TGR-CL system, remember to set the dip-switches of the new F3S-TGR-
CL system the same as the old one. Failure to do so may cause serious injury.