Wiring examples
Section 17-3
17-3-2 F3S-TGR-CL and G9SB-301-D in manual reset and Muting
connection
Note
For Active - Passive systems please keep in mind there is no wiring on Trans-
mitter (Passiv) side.
Note
The achievable safety category or performance level using this circuit
depends on the safety light curtain in use and the correct wiring of the safety
control unit.
Note
This circuit can achieve a PL=e acc. ISO 13849-1 if a F3S-TGR-CL-4_ is
used.
+24VDC (Bro
wn)
0VDC (Blue)
Mut.
B (Y
ello
w)
Mut.
A (Green)
Te
st/restar
t (White)
OSSD2 (Pink)
Feedback loop
+24VDC (Bro
wn)
Mut.
Lamp (Red)
0VDC (Blue)
Te
st (White)
F3S-TGR-CL
OSSD1 (Gr
ay)
Shield
Shield
24Vdc
+
-
KM1
KM2
Mut-A Mut-B
M
KM1
KM2
RECEIVER
S1
KM2
KM1
TRANSMITTER
S2
K1
K2
A1
T11 T12 T21 T22
T31 T32
13
23
33
41
42
34
24
14
A2
G9SB-301-D
CONTROL
CIRCUIT
K1
K2
F39-A11