System Operation and Functions
E
Timing chart
2-11-2. Factory Default Setting
The EDM function is disabled.
2-11-3. Setting with Intelligent Tap
The user can select the setting from EDM Enabled or Disabled by the DIP Switch. When enabling
EDM, the function operates under the following condition.
• Allowable delay time *: 0.3 s (factory default setting)
* By using SD Manager 3, this parameter can be set by 0.1 s in a range of 0.1 to 4.0 s.
Make sure the Position 2 of the DIP Switch is set at ON (DIP Switch Enabled) to activate the settings by the DIP Switch.
After making the setting, make sure to perform the wiring so that the specified voltage is supplied into the RESET line of
the receiver or emitter/receiver without passing through the NC contacts of the external relays, and confirm the F3SG-
SR/PG enters the LOCKOUT state.
Refer to
Chapter 3 Setting with Intelligent Tap
for more information on setting this function by the Intelligent Tap.
ON
OFF
ON
OFF
T1
Lockout
T1 max.
T1: Allowable delay time. This parameter can be set by 0.1 s in a range of 0.1 to 4.0 s.
Unblocked
Blocked
Beam state
OSSD
EDM
Summary of Contents for F3SG-PG Series
Page 18: ...xvi Introduction F3SG SR PG User s Manual...
Page 30: ...xxviii Introduction F3SG SR PG User s Manual...
Page 74: ...44 Chapter 1 List of Models F3SG SR PG User s Manual Overview and Specifications...
Page 180: ...150 Chapter 2 IO Link F3SG SR PG User s Manual System Operation and Functions...
Page 438: ...408 Chapter 7 Maintenance Checklists F3SG SR PG User s Manual Checklists...