72
Chapter
2
Ext
er
n
al
De
vi
ce Mo
ni
tori
ng
(
E
DM
)
F3SG-SR/PG
User’s Manual
System Operation and Functions
2-11-4. Setting with SD Manager 3
The user can make changes to the settings of this function by the SD Manager 3.
* Setting parameters of this function is saved according to the states where the Muting function is enabled and disabled,
respectively. After changing the Muting function from Enable to Disable or from Disable to Enable with the SD Manager 3, also
check the settings of this function again.
Refer to
Considerations for enabling and disabling Muting function with SD Manager 3
for more information.
It is recommended that the Position 2 of the DIP Switch be set at OFF (DIP Switch Disabled).
After you make any change to the setting, verify that the F3SG-SR/PG goes to the LOCKOUT state when the F3SG-SR/
PG is wired in such a way that the specified voltage is applied directly to the RESET line of the receiver or emitter/
receiver without the NC contact of an external device.
Refer to
4-3-2-1. Interlock/External Device Monitoring (EDM)/PSDI
for more information on setting this function by the SD
Manager 3.
Function
Initial value
Configurable value or numerical range
Muting function enabled*
Muting function disabled*
EDM
Disable
Disable
Enable/Disable
Allowable delay time
0.3 s
0.3 s
0.1 to 4 s in 0.1-s increments
Summary of Contents for F3SG-PG Series
Page 18: ...xvi Introduction F3SG SR PG User s Manual...
Page 30: ...xxviii Introduction F3SG SR PG User s Manual...
Page 74: ...44 Chapter 1 List of Models F3SG SR PG User s Manual Overview and Specifications...
Page 180: ...150 Chapter 2 IO Link F3SG SR PG User s Manual System Operation and Functions...
Page 438: ...408 Chapter 7 Maintenance Checklists F3SG SR PG User s Manual Checklists...