173
F3SG-SR/PG
User’s Manual
Ch
apt
e
r
3
Tea
c
h-
in
(F
ix Bla
n
king / Flo
a
ting
Blank
in
g
)
Setting with Intelligent Tap
E
(4) Transition to Teach-in Mode
Press and hold the Push Switch (for 3 s or longer) or turn the muting input A ON (for 3 s or longer) to
make the F3SG-SR transition to Teach-in mode. Upon transition the scan is started for the blocked
location. Move the blocking object in parallel with the F3SG-SR.
The object of the size of at least 1 beam must be moved. Failure to do so will result in a failure of
allowable beam setting.
When transitioned to Teach-in mode, the CFG indicator of the F3SG-SR receiver blinks.
(The mode transition to Teach-in mode does not occur if the setting of the DIP Switch is configured as
"Unlock", "DIP Switch Disabled" or "Floating Blanking Disabled".)
Indicator status of the F3SG-SR receiver in Teach-in mode.
*1 If F3SG-SRA is used with the wired synchronization setting, the ABI indicator of the emitter for the area blocked by an object
turns ON red.
(5) Result Check Process
Press the Push Switch (for within 1 s) or turn the muting input A ON (for within 1 s) automatically
configures the Floating Blanking setting based on the scan result.
*1
The determined setting is processed for valid/invalid judgment process in the sensor.
If the setting is invalid*2, SEQ indicator of the receiver blinks. In this case, try the steps again from (4).
Indicator status of the F3SG-SR receiver when Teach-in setting is valid or invalid
*1 The number of blanked beams is configured with the maximum number of blocked beams in the Teach-in process (steps (4) to (5)).
Allowable beams are is configured with (Maximum blocked beams - Minimum blocked beams) in the teach-in process.
The blanking monitoring function is configured as lockout.
LED Indicator
Status
SEQ
CFG
ABI *1
Area blocked by
blocking object is
illuminated in red
Teach-in setting is valid
Teach-in setting is invalid
LED Indicator
Status
LED Indicator
Status
SEQ
SEQ
CFG
CFG
ABI *3
Area blocked by
blocking object is
illuminated in red
ABI *3
Area blocked by
blocking object is
illuminated in red
OFF
Blinking
OFF
Blinking
illuminated
Blinking
Summary of Contents for F3SG-PG Series
Page 18: ...xvi Introduction F3SG SR PG User s Manual...
Page 30: ...xxviii Introduction F3SG SR PG User s Manual...
Page 74: ...44 Chapter 1 List of Models F3SG SR PG User s Manual Overview and Specifications...
Page 180: ...150 Chapter 2 IO Link F3SG SR PG User s Manual System Operation and Functions...
Page 438: ...408 Chapter 7 Maintenance Checklists F3SG SR PG User s Manual Checklists...