225
F3SG-SR/PG
User’s Manual
Chapter
4
Ba
si
c O
p
era
tio
n
of
SD
M
a
n
a
ge
r 3
Setting with SD Manager 3
E
Confirming with Intelligent Tap
You can check the lot number of the Intelligent Tap from the marking on the Intelligent Tap body. See the
figure below for the location of the marking.
4-2-6-5. Resetting the Initial Password to “0000”
1.
Log in at the operator level. (No password is needed to log in at the operator level.)
For login at the operator level, refer to
.
2.
Select the [Clear Password] button
from the [Account] menu at the screen top of SD Manager 3.
Or, click the [Clear Password] button
directly from the tool menu.
3.
Fill in the clear password window with the clearing password provided by Omron and press OK.
(A message saying that password initialization has succeeded is displayed on the [Tool Message] field
at the screen bottom of SD Manager 3.)
4.
It is necessary to restart the Intelligent Tap to switch the password. Restart the Intelligent Tap
according to procedure 4 of
4-1-3-2. Connection Procedure When Using USB Connector
. After the
Intelligent Tap is restarted, the administrator password is brought back to “0000.”
Lot Number
Summary of Contents for F3SG-PG Series
Page 18: ...xvi Introduction F3SG SR PG User s Manual...
Page 30: ...xxviii Introduction F3SG SR PG User s Manual...
Page 74: ...44 Chapter 1 List of Models F3SG SR PG User s Manual Overview and Specifications...
Page 180: ...150 Chapter 2 IO Link F3SG SR PG User s Manual System Operation and Functions...
Page 438: ...408 Chapter 7 Maintenance Checklists F3SG SR PG User s Manual Checklists...