191
F3SG-SR/PG
User’s Manual
Ch
apt
e
r
3
In
te
lligent
Tap Applicat
ion Examp
le
Setting with Intelligent Tap
E
To finish the maintenance task and start normal operation of the facility,
perform the followings.
1.
Use a Phillips screwdriver to attach the cover of the intelligent tap.
(Recommended tightening torque: 0.35
Nm)
2.
If a cable is not attached to CN3, use the torque wrench XY2F-0004 to attach the accessory
waterproof cover (for plug).
(Recommended tightening torque for waterproof cover (for plug): 0.39 to 0.49N
m)
3.
If a cable is not attached to CN4, attach the accessory waterproof cover (for socket).
3-10-4.
Replacing Intelligent Tap
Replace the existing intelligent tap with a new one.
3-10-4-1. Setting with DIP-SW
This applies to a case that F3SG-SR/PG settings were changed by DIP-SW.
Work steps
1.
If power of the intelligent tap or F3SG-SR/PG is ON, turn it OFF.
2.
Remove the existing intelligent tap from the facility.
3.
Remove the cover of the new intelligent tap to attach.