15
F3SJ-B
User’s Manual
Chapter
2
Des
c
ript
io
n o
f Fun
ction
s
System Configuration and Functions
E
Auxiliary Output Function
The auxiliary output is used to monitor the status of the F3SJ-B. This output can be connected to a
device such as programmable controller.
Do not use the auxiliary output for safety applications.
Human body may not be detected when F3SJ-B fails, resulting in serious injury.
Unblocked
/Blocked
Unblocked
Blocked
Safety output
Auxiliary output
ON
OFF
ON
OFF
15 ms
30 ms max.
30 ms max.
70 ms