42
Ch
apt
e
r
3
Dimen
s
ions
F3SJ-B
User’s Manual
Wiring/Installation
When Using Replacement Brackets
Backside mounting
Bracket mounting procedure (Mounting) p.49
If the protective height is more than 1105 mm, use Intermediate Brackets of the quantities and locations according to
the dimensions described on page 29 "When Using Top/Bottom and Intermediate Brackets". If the brackets described
above are not used, ratings and performance cannot be met.
19
4-M5
B
Replacement Bracket
(F39-LJB4)
Replacement Bracket
(F39-LJB4)
43
13
30
19
6.5
62
30
B
C (Protective height)
A
79.5
36.5
[ Unit : mm ]
M3 x 6 screw
M3 x 6 screw
Dimensions A to C
A
C+159
B
C+86
C
4-digit number of the type name (protective height)
Summary of Contents for F3SJ-B Series
Page 1: ...F3SJ B N25 01T Series Safety Light Curtain User s Manual Cat No SCHG 735E...
Page 12: ...x Introduction F3SJ B User s Manual...
Page 30: ...16 Chapter 2 Description of Functions F3SJ B User s Manual System Configuration and Functions...
Page 84: ...70 Chapter 3 Wiring F3SJ B User s Manual Wiring Installation...
Page 90: ...76 Chapter 4 Wiring Examples F3SJ B User s Manual Input Output Circuit and Applications...
Page 96: ...82 Chapter 5 Maintenance Checklists F3SJ B User s Manual Checklists...