CSM_F3SP-T01_DS_E_3_1
1
Safety Terminal Relays (for F3SJ-A
@@@@
P
@@
)
F3SP-T01
Simplifies wiring from Safety Light
Curtains to the Safety Relay outputs.
• Simplifies wiring inside the panel and helps prevent incorrect
wiring.
• Terminals are numbered to make it easy to check terminal
connections.
• Replacement of relays is easy, improving maintainability.
• Screw-less clamp terminals eliminate the need for extra
tightening.
• The Support Software can be connected, enabling on-site
adjustment of Light Curtains.
Ordering Information
Safety Terminal Relays
Optional Accessories (Sold Separately)
Specifications
(Refer to Instruction Manual for details.)
Ratings
Power supply
Contacts
Characteristics
Durability
As of June 2009
Be sure to read the
“Safety Precautions”
on page 8 and
the
“Precautions for All Safety Sensors”
.
Type
Applicable models
Model
Safety Terminal Relay
F3SJ-A
@@@@
P
@@
F3SP-T01
Type
Model
Cable for connecting Support Software (cable length: 1.5 m)
E39-Z12-1
Replacement Relay
G7SA-3A1B
Rated voltage
24 VDC+10%/
−
15%
Rated power
consumption
DC 1.7 W max. (not including sensor's power
consumption)
Rated load
250 VAC 3 A, resistive load
30 VDC 3 A, resistive load
Rated current
3 A
Applicable Relays
G7SA-3A1B: 24 VDC
Operation time
100 ms max.
(not including sensor's response time)
Response time
10 ms max.
(not including sensor's response time)
Vibration
resistance
10 to 55 to 10 Hz
Single amplitude: 0.35 mm
(Double amplitude: 0.7 mm)
Shock resistance
Destruction: 300 m/s
2
, Malfunction: 100 m/s
2
Ambient operating
temperature
−
10 to 55
°
C
Ambient operating
humidity
35 to 85%
Weight
Approx. 215 g
Electrical
durability
100,000 operations min.
Rated load
Switching frequency: 1,800 operations/h
Mechanical
durability
5,000,000 operations min.
Switching frequency: 7,200 operations/h