F3SP-T01
9
•
Apply the specified voltages to the input terminals. Applying an
inappropriate voltage may prevent specified functions from
operating properly, which may cause damage to the product or
burning.
•
Disconnect the power supply before wiring.
•
Check the condition of the emitter and receiver before connecting
them.
•
You cannot use the product if the positive side is connected to
ground.
•
NC terminals have no function. Do not connect them.
Wiring the Terminal Block
•
Insert the wires using the following procedure.
Flexible wires: (1) Use a flat-blade screwdriver to push in the lever
and (2) insert the wire.
Solid wires or ferrules: Insert the wire into the wire hole and push
all the way to the back. (Operating the lever is not required.)
•
Remove the wires using the following procedure (same for flexible
wires, solid wires, and ferrules).
(1) Use a flat-blade screwdriver to push in the lever and (3) pull out
the wire.
•
Use a flat-blade screwdriver that has the same thickness from tip
to base and is within the following standards.
Mounting to and Removing from DIN Track
•
To mount the product to a DIN Track, release the slider lock, place
the product on the DIN track, and then lock the slider.
•
After using the slider lock, make sure that the lock is engaged on
the DIN Track.
•
To dismount the product from the DIN Track, place the driver in the
slider section, release the lock, and then remove the product from
the DIN Track.
•
Secure both ends of the Safety
Terminal Relays with End Plates.
The following products are sold
separately.
Selecting the Power Supply
•
Use the rated power supply voltage. Do not use power supplies
with large ripple component or intermittent irregular voltages.
•
To meet IEC 61496-1 and UL 508 safety standards and to prevent
electrical shock, make sure that the power supply and load satisfy
the requirements outlined in the sensor's user manual.
Periodic Checks and Maintenance
•
Do not attempt to disassemble, repair, or modify the product.
•
Make sure that the power supply is turned OFF before replacing
parts.
Disposal
•
Exercise caution to prevent injury when disassembling the F3SP-
T01.
Durability of Contact Outputs
The durability of the contact outputs on Safety Terminal Relays varies
considerably depending on switching conditions. Always confirm the
usage conditions by testing the Safety Terminal Relay in an actual
application, and use the Safety Terminal Relay only for the number of
switching operations that its performance allows. Restarting may not
be possible if the switching capacity is exceeded. If this occurs,
replace the relevant relays immediately. If a Safety Terminal Relay is
used after performance has deteriorated, it may result in reduced
safety.
(3) (2)
(1)
Lever
Insert wire here
Side
view
Front
view
D
E
We recommend the following flat-blade
screwdrivers for inserting wires.
Recommended Screwdrivers
Dimension D
0.3 to 0.8
Dimension E
2.9 to 3.6
Model
XW4Z-00B
XW4Z-00C
DIN Tracks
PFP-50N
PFP-100N
End Plate
PFP-M
Precautions for Correct Use
Screwdriver
Slider