F3SP-T01

9

Apply the specified voltages to the input terminals. Applying an 
inappropriate voltage may prevent specified functions from 
operating properly, which may cause damage to the product or 
burning.

Disconnect the power supply before wiring.

Check the condition of the emitter and receiver before connecting 
them.

You cannot use the product if the positive side is connected to 
ground.

NC terminals have no function. Do not connect them.

Wiring the Terminal Block

Insert the wires using the following procedure. 
Flexible wires: (1) Use a flat-blade screwdriver to push in the lever 
and (2) insert the wire.
Solid wires or ferrules: Insert the wire into the wire hole and push 
all the way to the back. (Operating the lever is not required.) 

Remove the wires using the following procedure (same for flexible 
wires, solid wires, and ferrules).
(1) Use a flat-blade screwdriver to push in the lever and (3) pull out 
the wire.

Use a flat-blade screwdriver that has the same thickness from tip 
to base and is within the following standards.

Mounting to and Removing from DIN Track

To mount the product to a DIN Track, release the slider lock, place 
the product on the DIN track, and then lock the slider.

After using the slider lock, make sure that the lock is engaged on 
the DIN Track.

To dismount the product from the DIN Track, place the driver in the 
slider section, release the lock, and then remove the product from 
the DIN Track.

Secure both ends of the Safety 
Terminal Relays with End Plates.
The following products are sold 
separately.

Selecting the Power Supply

Use the rated power supply voltage. Do not use power supplies 
with large ripple component or intermittent irregular voltages.

To meet IEC 61496-1 and UL 508 safety standards and to prevent 
electrical shock, make sure that the power supply and load satisfy 
the requirements outlined in the sensor's user manual.

Periodic Checks and Maintenance

Do not attempt to disassemble, repair, or modify the product.

Make sure that the power supply is turned OFF before replacing 
parts.

Disposal

Exercise caution to prevent injury when disassembling the F3SP-
T01.

Durability of Contact Outputs

The durability of the contact outputs on Safety Terminal Relays varies 
considerably depending on switching conditions. Always confirm the 
usage conditions by testing the Safety Terminal Relay in an actual 
application, and use the Safety Terminal Relay only for the number of 
switching operations that its performance allows. Restarting may not 
be possible if the switching capacity is exceeded. If this occurs, 
replace the relevant relays immediately. If a Safety Terminal Relay is 
used after performance has deteriorated, it may result in reduced 
safety. 

(3) (2)

(1)

Lever

Insert wire here 

Side
view

Front

view

D

E

We recommend the following flat-blade 
screwdrivers for inserting wires.

Recommended Screwdrivers

Dimension D

0.3 to 0.8

Dimension E

2.9 to 3.6

Model

XW4Z-00B

XW4Z-00C

DIN Tracks

PFP-50N
PFP-100N

End Plate

PFP-M

Precautions for Correct Use

Screwdriver

Slider

Summary of Contents for F3SP-T01

Page 1: ...or All Safety Sensors Type Applicable models Model Safety Terminal Relay F3SJ A P F3SP T01 Type Model Cable for connecting Support Software cable length 1 5 m E39 Z12 1 Replacement Relay G7SA 3A1B Rat...

Page 2: ...G AUX V G 1 2 3 4 13 14 23 24 NC NC 23 24 33 34 43 44 43 44 11 12 11 12 Receiver Emitter L1 Muting input 1 White L2 24 V Brown L3 Test input Green L4 Reset input Yellow L5 Communications line Gray L6...

Page 3: ...e mounted to the F3SJ 2 If a lockout reset is required connect a switch between RST and V Connecting Four Muting Sensors Note If you are connecting four muting sensors connect the sensor outputs to MA...

Page 4: ...4 V Brown Control output 2 White 0 V Blue External device monitoring input Red Control output 1 Green Shield Communications line Gray Auxiliary output Yellow Communications line Pink Note If a lockout...

Page 5: ...utput Muting output Muting Sensor 1 Muting Sensor 2 Muting Sensor 3 Muting Sensor 4 Connecting Four Muting Sensors Note If you are connecting four muting sensors connect the sensor outputs to MA1 MA2...

Page 6: ...ld Communications line Gray Reset input Yellow Communications line Pink 24 V Brown Control output 2 White 0 V Blue External device monitoring input Red Control output 1 Green Shield Communications lin...

Page 7: ...ntact output terminals 180 Two 4 2 dia holes 55 169 51 40 I O terminals Status indicators LEDs From left to right PWR RY1 K1 RY2 K2 TEST RESET and AUX G7SA 3A1B K1 G7SA 3A1B K2 Modular Connector for L...

Page 8: ...ater oil or chemicals Locations subject to dust including iron dust or salts Take appropriate and sufficient countermeasures when using the product in the following locations Locations subject to stat...

Page 9: ...m the DIN Track Secure both ends of the Safety Terminal Relays with End Plates The following products are sold separately Selecting the Power Supply Use the rated power supply voltage Do not use power...

Page 10: ...products Outdoor use uses involving potential chemical contamination or electrical interference or conditions or uses not described in this catalog Nuclear energy control systems combustion systems r...

Reviews: