F3SP-U3P-TGR
User's manual
16
7 OPERATING
PROCEDURES.
7-1 DIP-SWITCHES
CONFIGURATION.
The configuration indicated in the table must be selected on the
dip
-
switch
available in the front.
4
Function
X not
used
3
Function
Off
muting A-B act on the sensor
couples 1 and 2.
On
muting A-B act on the sensor
couple 1.
2
Function
Off
muting 60 s
On
muting
∞
s *
1
Function
Off manual
restoring
On automatic
restoring
The control-unit is manufactured from the factory with the following configuration:
•
Automatic reset, all 2 sensors in
muting
, the maximum duration of
the
muting
is of sixty seconds.
*
infinite muting duration: this feature must be used carefully because it’s
against the norm. Using this, the user must know that it works under its sole
responsibility.
7-2
CONFIGURATION OF THE NUMBER OF PHOTOCELLS.
In case you use only a pair of photocells, operate as follows:
Turn off the power and short the terminal 11-12.
At least one pair of photocells must be connected, otherwise the control unit
is locked.